W DOC AIRBUS | AMM A320F

Removal of the Starter Air Valve (SAV) [CFML]


TASK 80-11-15-000-801-A
Removal of the Starter Air Valve (SAV)


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
WARNING: IF IT IS NECESSARY TO ENERGIZE THE AIRCRAFT FOR MAINTENANCE WORK WHILE YOU DO THIS MAINTENANCE PROCEDURE, MAKE SURE THAT ONLY EXTERNAL POWER IS USED. THE USE OF APU OR ENGINE POWER CAN CAUSE PRESSURIZED AIR LEAKAGE IN THE PNEUMATIC SYSTEM AND INJURY CAN OCCUR.
ZONE: 210
ZONE: 400
FIN: 4005KS
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - PROTECTION
No specific
AR
COVER - PROTECTION
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
400
POWER PLANT, NACELLES AND PYLONS
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-803-A
Opening of the Fan Cowl Doors
3. Job Set-up
Subtask 80-11-15-941-050-A
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
     (c) Put WARNING NOTICE(S) in position to tell persons not to operate:
  • The ENG/MODE selector switch and
  • The ENG/MASTER 1(2) control switch.
   (2) On the ENG section of maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
   (3) On the overhead control and indicator panel 25VU, on the APU section:
     (a) Make sure that the APU MASTER SW pushbutton is released.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to operate the APU.
   (4) On the HP ground connector:
     (a) Put a WARNING NOTICE(S) in position to tell persons not to pressurize the pneumatic system.
Subtask 80-11-15-010-050-A
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
4. Procedure
Subtask 80-11-15-020-050-A
A. Removal of the Starter Air Valve (SAV)
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNECT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CAUSE DAMAGE TO EQUIPMENT.
   (1) Disconnect the two HJ6A harness electrical connectors (2) and (10) from the sockets (11) and (12) of the SAV (1).
   (2) Loosen the nut (4) from the tightener (6).
   (3) Remove the V-band clamp (5) that attaches the starter air duct (3) to the SAV (1).
   (4) Remove and discard seal (14).
   (5) Loosen the nut (7) from the V-band clamp (8) that attaches the SAV (1) to the pneumatic air starter (9).
   (6) Remove the SAV (1) from the pneumatic air starter (9).
   (7) Remove and discard the seal (13).
   (8) Install COVER - PROTECTION and CAP - PROTECTION on all the open ports, open tubes, open hoses and the disconnected connectors.
[Rev.10 from 2021] 2026.04.01 03:45:33 UTC