W DOC AIRBUS | AMM A320F

Installation of the Right Thrust Reverser Thermal Insulation Blankets [PW11]


TASK 78-32-71-400-802-A
Installation of the Right Thrust Reverser Thermal Insulation Blankets


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AND THE ADJACENT COMPONENTS AFTER ENGINE SHUTDOWN. THE ENGINE, THE ENGINE OIL AND THE ADJACENT COMPONENTS CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING: WEAR APPLICABLE PERSONAL PROTECTIVE EQUIPMENT (PPE) WHEN YOU DO THIS TASK. BEFORE YOU USE PPE, READ, UNDERSTAND AND OBEY ALL INSTRUCTIONS FOR ITS USE. THESE INSTRUCTIONS INCLUDE INSTRUCTIONS FROM THE MANUFACTURER, YOUR EMPLOYER AND GOVERNMENT REGULATIONS. YOU CAN GET INJURED IF YOU DO NOT USE PPE. GET INSTRUCTIONS FROM YOUR EMPLOYER ON WHICH PPE IS NECESSARY.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 400
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
No specific
Torque wrench: range to between 27 and 23 lbf.in (0.31 and 0.26 m.daN ) T
No specific
Torque wrench: range to between 27 and 24 lbf.in (0.31 and 0.27 m.daN ) T
No specific
Torque wrench: range to between 130 and 117 lbf.in (1.47 and 1.32 m.daN ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.PU4-0010)
base primer
(Material No.PU4-0011)
activator
(Material No.PU4-0012)
thinner
(Material No.PU5-0002)
anti-seize compound
(Material No.PU5-0005)
anti-seize compound
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR, 452AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR, 462AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 71-00-00-860-833-A
Procedure to Prevent Engine Motoring
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-802-A
Closing of the Fan Cowl Doors
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-30-00-440-805-A
Reactivation of the Thrust Reverser System after Ground Maintenance
TASK 78-32-72-400-802-A
Installation of the Right Thrust-Reverser Seals
TASK 78-36-00-010-802-A
Opening of the Thrust Reverser Cowl-Doors
TASK 78-36-00-410-802-A
Closing of the Thrust Reverser Cowl-Doors
3. Job Set-up
Subtask 78-32-71-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 78-32-71-010-052-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR
   (2) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
Subtask 78-32-71-040-051-A ** ON A/C NOT FOR ALL
C. Deactivation of the Thrust Reverser for Ground Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Make sure that you did the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 78-32-71-010-053-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Make sure that the right thrust-reverser cowl-door is open (Ref. AMM TASK 78-36-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR
4. Procedure
Subtask 78-32-71-420-051-A ** ON A/C NOT FOR ALL
A. Installation of the Right Thrust Reverser Thermal Insulation Blankets
CAUTION: MAKE SURE THE THERMAL INSULATION BLANKETS ARE FLAT ON THE SURFACE OF THE INNER FIXED STRUCTURE. LARGE GAPS UNDER THE BLANKETS CAN MAKE THE INSULATION UNSATISFACTORY, WHICH CAN CAUSE DAMAGE TO THE EQUIPMENT.
CAUTION: DO NOT LET THE THERMAL INSULATION BLANKETS BECOME WET. FLUIDS CAN GO INTO THE VENT HOLES OF THE BLANKETS AND MAKE THE INSULATION UNSATISFACTORY.
CAUTION: BE CAREFUL WHEN YOU MOVE THE THERMAL INSULATION BLANKETS. IF YOU DO NOT HOLD THE BLANKETS CORRECTLY, THEY CAN FOLD BECAUSE OF THEIR OWN WEIGHT. DO NOT STEP ON OR PUT OBJECTS ON THE BLANKETS. DO NOT PUT THE BLANKETS ON SURFACES THAT CAN CAUSE DAMAGE. HOLD THE BLANKETS ON THEIR THICKEST PARTS. IF YOU DO NOT OBEY THESE INSTRUCTIONS, DAMAGE TO THE BLANKETS CAN OCCUR.
CAUTION: DO NOT INSTALL MORE THAN 30 WASHERS AT EACH BUMPER POSITION ON EACH THRUST-REVERSER HALF. IF YOU INSTALL TOO MANY WASHERS, THERE IS A RISK THAT THE BOLT WILL NOT ENGAGE THE LOCKING FEATURE SUFFICIENTLY. THIS CAN CAUSE THE BOLT, THE BUMPER PAD AND THE WASHERS TO DISENGAGE FROM THE THRUST REVERSER.
CAUTION: MAKE SURE THAT THE PRIMER MIXTURE DOES NOT GO ON THE THREADS OF THE BOLT OR ON THE HELICOIL IN THE BOLT HOLE. IF THERE IS PRIMER MIXTURE ON THE THREADS OR ON THE HELICOIL, THE HELICOIL CAN BECOME DAMAGED DURING SUBSEQUENT REMOVAL OF THE BOLT.
CAUTION: WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE.
   (1) Removal of the protection covers:
CAUTION: REMOVE THE PROTECTION COVERS FROM THE OPENINGS AS NECESSARY TO PREVENT ENGINE DAMAGE.
     (a) Make sure that you remove all the necessary COVER - PROTECTION to prevent damage to the engine and adjacent components.
   (2) Installation of the lower aft barrel blanket (24):
     (a) Put the lower aft barrel blanket (24) on the inner fixed structure of the right thrust reverser.
     (b) Make sure that the bottom edge of the lower aft barrel blanket (24) is under the blanket retainer.
     (c) Make sure that all the other edges are between 0 in. (0.00 mm) and 0.15 in. (3.81 mm) from the adjacent structures on the inner fixed structure.
     (d) Attach the lower aft barrel blanket (24) to the inner fixed structure with the 15 retainers (2).
     (e) TORQUE the 15 retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN ) T.
NOTE: If the retainer (2) is not tight against the blanket after you tighten it, you can put one washer under the retainer (2).
   (3) Installation of the forward latch beam blanket (21):
     (a) Put the forward latch beam blanket (21) on the inner fixed structure.
     (b) Make sure that the forward edge of the forward latch beam blanket (21) is under the retainer for the forward seal.
     (c) Make sure that all the other edges of the forward latch beam blanket (21) are between 0 in. (0.00 mm) and 0.15 in. (3.81 mm) from the adjacent structures on the inner fixed structure.
     (d) Attach the forward latch beam blanket (21) with the two retainers (2).
     (e) TORQUE the two retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN )
T.
NOTE: If the retainer (2) is not tight against the blanket after you tighten it, you can put one washer under the retainer (2).
     (f) Attach the forward latch beam blanket (21) to the panel with the nut (22) and the washer (23).
     (g) TORQUE the nut (22) to between 27 and 24 lbf.in (0.31 and 0.27 m.daN )
T.
   (4) Installation of the bifurcation latch system latch blanket (19):
     (a) Apply a layer of the anti-seize compound (Material No.
PU5-0002) to the threads of the retainers (18).
     (b) Put the bifurcation latch system latch blanket (19) on the inner fixed structure.
     (c) Attach the bifurcation latch system latch blanket (19) with the two retainers (18).
     (d) TORQUE the two retainers (18) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN ) T.
   (5) Preparation of the bolt (8) for the bumper pad (9):
     (a) Apply the anti-seize compound (Material No.
PU5-0005) to the lowest 0.5 in. (12.70 mm) of threads on the bolt (8).
     (b) Mix the base primer (Material No.PU4-0010) with the activator (Material No.PU4-0011) and the thinner (Material No.PU4-0012) . Refer to the instructions of the manufacturer.
     (c) Put a layer of the base primer (Material No.PU4-0010) mixture below the head of the bolt (8).

PRE SB GRAA320NEO-A-78-30-0006-00001-930A-D

   (6) Installation of the lower forward barrel blanket (16):
     (a) Put the washers (10) under the hole for the bumper pad (9) and the bolt (8) on the lower forward barrel blanket (16).
       1 Install the washers (10) in the same location as recorded during removal.
     (b) Put the lower forward barrel blanket (16) on the inner fixed structure.
     (c) Wet install the bolt (8) and the washers (10) on the lower forward barrel blanket (16) and the washers (10) under the blanket (16).
     (d) Tighten the bolt (8) with your hand.
       1 Install the washers (10) in the same location as recorded during removal.
     (e) Make sure that the forward edge of the lower forward barrel blanket (16) is under the retainers for the forward seals.
     (f) Make sure that all the other edges of the lower forward barrel blanket (16) are between 0 in. (0.00 mm) and 0.15 in. (3.81 mm) from the adjacent structures on the inner fixed structure.
     (g) Attach the lower forward barrel blanket (16) to the inner fixed structure with the 20 retainers (2).
     (h) TORQUE the 20 retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN ) T.
NOTE: If a retainer (2) is not tight against the blanket after you tighten it, you can put one washer under the retainer (2).
     (i) TORQUE the bolt (8) to between 130 and 117 lbf.in (1.47 and 1.32 m.daN )
T.

END OF PRE SB GRAA320NEO-A-78-30-0006-00001-930A-D

POST SB GRAA320NEO-A-78-30-0006-00001-930A-D

   (7) Installation of the lower forward barrel blanket (27):
     (a) Put the washers (10) under the hole for the bumper pad (9) and the bolt (8) on the lower forward barrel blanket (27).
       1 Install the washers (10) in the same location as recorded during removal.
     (b) Put the lower forward barrel blanket (27) on the inner fixed structure.
     (c) Wet install the bolt (8) and the washers (10) on the lower forward barrel blanket (27) and the washers (10) under the lower forward barrel blanket (27).
     (d) Tighten the bolt (8) with your hand.
       1 Install the washers (10) in the same location as recorded during removal.
     (e) Make sure that the forward edge of the lower forward barrel blanket (27) is under the retainers for the forward seals.
     (f) Make sure that all other edges of the lower forward barrel blanket (27) are between 0.00 in. (0.00 mm) and 0.15 in. (3.81 mm) from the adjacent structures on the inner fixed structure.
     (g) Attach the lower forward barrel blanket (27) to the inner fixed structure with the 21 retainers (2).
     (h) TORQUE the 21 retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN )
T.
NOTE: If a retainer (2) is not tight against the blanket after you tighten it, you can put one washer under the retainer (2).
     (i) TORQUE the bolt (8) to between 130 and 117 lbf.in (1.47 and 1.32 m.daN )
T.

END OF POST SB GRAA320NEO-A-78-30-0006-00001-930A-D

   (8) Installation of the fireshield bracket (26):
     (a) Put the fireshield bracket (26) on the lower forward barrel blanket (16) or (27) and the inner fixed structure.
     (b) Attach the fireshield bracket (26) to the inner fixed structure with the three retainers (2).
NOTE: If a retainer (2) is not tight against the bracket after you tighten it, you can put one washer under the retainer (2).
     (c) TORQUE the three retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN )
T.
NOTE: If a retainer (2) is not tight against the blanket after you tighten it, you can put one washer under the retainer (2).
   (9) Installation of the covers on the vents on the lower forward barrel blanket (16) or (27):
     (a) Install the zone vent cover (15) on the zone vent tube on the lower forward barrel blanket (16) or (27) with the two retainers (2).
     (b) TORQUE the two retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN )
T.
NOTE: If a retainer (2) is not tight against the cover after you tighten it, you can put one washer under the retainer (2).
     (c) Install the zone vent cover (20) on the zone vent tube on the lower forward barrel blanket (16) or (27) with the two retainers (2).
     (d) TORQUE the two retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN )
T.
NOTE: If a retainer (2) is not tight against the cover after you tighten it, you can put one washer under the retainer (2).

PRE SB GRAA320NEO-A-78-30-0006-00001-930A-D

     (e) Install the zone vent deflector assembly (17) on the zone vent tube on the lower forward barrel blanket (16).
     (f) Use the two retainers (2) and the two washers (25).
     (g) Put the washers (25) under the zone vent deflector assembly (17).
     (h) TORQUE the two retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN )
T.
NOTE: If a retainer (2) is not tight against the deflector assembly after you tighten it, you can put one washer under the retainer (2).

END OF PRE SB GRAA320NEO-A-78-30-0006-00001-930A-D

   (10) Installation of the aft latch beam blanket (14):
     (a) Put the aft latch beam blanket (14) on the inner fixed structure.
     (b) Make sure that the aft edge of the aft latch beam blanket (14) is under the support.
     (c) Make sure that all the other edges of the aft latch beam blanket (14) are between 0 in. (0.00 mm) and 0.15 in. (3.81 mm) from the adjacent structures on the inner fixed structure.
     (d) Attach the aft latch beam blanket (14) to the inner fixed structure with the six retainers (2).
     (e) TORQUE the six retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN )
T.
NOTE: If a retainer (2) is not tight against the blanket after you tighten it, you can put one washer under the retainer (2).
   (11) Installation of the upper aft barrel blanket (11):
     (a) Put the upper aft barrel blanket (11) on the inner fixed structure.
     (b) Make sure that the top edges of the upper aft barrel blanket (11) are under the retainers for the pylon seal support and the stiffener.
     (c) Make sure that all the other edges of the upper aft barrel blanket (11) are between 0 in. (0.00 mm) and 0.15 in. (3.81 mm) from the adjacent structures on the inner fixed structure.
     (d) Attach the right upper aft barrel blanket (11) to the inner fixed structure with the 35 retainers (2).
     (e) TORQUE the 35 retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN )
T.
NOTE: If a retainer (2) is not tight against the blanket after you tighten it, you can put one washer under the retainer (2).
     (f) Apply the anti-seize compound (Material No.
PU5-0005) to the lowest 0.5 in. (12.70 mm) of threads on the bolt (8).
     (g) Mix the base primer (Material No.PU4-0010) with the activator (Material No.PU4-0011) and the thinner (Material No.PU4-0012) . Refer to the instructions of the manufacturer.
     (h) Install the bumper pad (9) on the upper aft barrel blanket (11) with the bolt (8) and the washers (10).
     (i) Wet install the bolt (8) with the base primer (Material No.PU4-0010) mixture below the head of the bolt.
       1 Install the washers (10) in the same location as recorded during removal.
     (j) TORQUE the bolt (8) to between 130 and 117 lbf.in (1.47 and 1.32 m.daN ) T.
   (12) Installation of the covers on the vents on the upper aft barrel blanket (11):
     (a) Install the zone vent cover (13) on the zone vent tube on the upper aft barrel blanket (11) with the two retainers (2).
     (b) TORQUE the two retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN )
T.
NOTE: If a retainer (2) is not tight against the blanket after you tighten it, you can put one washer under the retainer (2).
     (c) Install the zone vent cover (12) on the zone vent tube on the upper aft barrel blanket (11) with the two retainers (2).
     (d) TORQUE the two retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN )
T.
NOTE: If a retainer (2) is not tight against the cover after you tighten it, you can put one washer under the retainer (2).
   (13) Install the Active Clearance Control (ACC) seal and the ACC shield on the right upper aft barrel blanket (11) (
Ref. AMM TASK 78-32-72-400-802).
   (14) Installation of the upper forward barrel blanket (1) and the upper bifurcation bumper blanket (7):
     (a) Put the upper forward barrel blanket (1) and the upper bifurcation bumper blanket (7) on the inner fixed structure.
     (b) Make sure that the forward and top edges of the upper forward barrel blanket (1) and the upper bifurcation bumper blanket (7) are under the retainers for the forward and top seals.
     (c) Make sure that all the other edges of the upper forward barrel blanket (1) are between 0 in. (0.00 mm) and 0.15 in. (3.81 mm) from the adjacent structures on the inner fixed structure.
     (d) Attach the upper forward barrel blanket (1) and the upper bifurcation bumper blanket (7) to the inner fixed structure with the 27 retainers (2).
     (e) TORQUE the 27 retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN ) T.
NOTE: If a retainer (2) is not tight against the blanket after you tighten it, you can put one washer under the retainer (2).
     (f) Apply the anti-seize compound (Material No.
PU5-0005) to the lowest 0.5 in. (12.70 mm) of threads on the bolt (8).
     (g) Mix the base primer (Material No.PU4-0010) with the activator (Material No.PU4-0011) and the thinner (Material No.PU4-0012) . Refer to the instructions of the manufacturer.
     (h) Install the bumper pad (9) on the right upper forward barrel blanket (1) with the bolt (8) and the washers (10).
     (i) Wet install the bolt (8) with the base primer (Material No.PU4-0010) mixture below the head of the bolt.
       1 Install the washers (10) in the same location as recorded during removal.
     (j) TORQUE the bolt (8) to between 130 and 117 lbf.in (1.47 and 1.32 m.daN ) T.
   (15) Installation of the covers on the vents on the upper forward barrel blanket (1):
     (a) Attach the zone vent deflector (6) on the zone vent tube on the upper forward barrel blanket (1) with the two retainers (2).
     (b) TORQUE the two retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN )
T.
NOTE: If a retainer (2) is not tight against the deflector after you tighten it, you can put one washer under the retainer (2).
     (c) Attach the zone vent cover (4) on the zone vent tube on the upper forward barrel blanket (1) with the two retainers (2).
     (d) TORQUE the two retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN )
T.
NOTE: If a retainer (2) is not tight against the cover after you tighten it, you can put one washer under the retainer (2).
     (e) Attach the zone vent deflector (5) on the zone vent tube on the upper forward barrel blanket (1) with the two retainers (2).
     (f) TORQUE the two retainers (2) to between 27 and 23 lbf.in (0.31 and 0.26 m.daN )
T.
NOTE: If a retainer (2) is not tight against the deflector after you tighten it, you can put one washer under the retainer (2).
5. Close-up
Subtask 78-32-71-860-050-A ** ON A/C NOT FOR ALL
Subtask 78-32-71-440-050-A ** ON A/C NOT FOR ALL
B. Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 78-32-71-410-050-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 03:33:44 UTC