2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 78-31-00-941-054-A ** ON A/C NOT FOR ALL
Subtask 78-31-00-210-053-A ** ON A/C NOT FOR ALL
Subtask 78-31-00-410-060-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 03:24:00 UTC
General Visual Inspection of Primary Latch Mechanism (Blocker Doors Deployed)
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the JobRefer to the MPD TASK: 783100-C7
GENERAL VISUAL INSPECTION OF PRIMARY LATCH MECHANISM (BLOCKER DOORS DEPLOYED)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| HIX3005 | 1 | SAFETY SLEEVE - PIVOTING DOOR ACTUATOR |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-B | Closing of the Fan Cowl Doors |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-31-19-000-001-A | Removal of the Blocker Door Latches |
| TASK 78-31-19-400-001-A | Installation of the Blocker Door Latches |
| TASK 78-31-49-400-042-A | Installation of the Upper Supply Pipe of the Left Latch |
| TASK 78-31-49-400-043-A | Installation of the Lower Supply Pipe of the Left Latch |
| TASK 78-31-49-400-044-A | Installation of the Lower Supply Pipe of the Right Latch |
| TASK 78-31-49-400-045-A | Installation of the Upper Supply Pipe of the Right Latch |
| TASK 78-32-41-000-003-A | Removal of the Latch Fitting and Latch Back Plate |
| TASK 78-32-41-080-001-A | Removal of the Safety Sleeve from Blocker Door Actuator |
| TASK 78-32-41-400-003-A | Installation of the Latch Fitting and Latch Back Plate |
| TASK 78-32-41-480-001-A | Installation of the Safety Sleeve on Blocker Door Actuator |
| TASK 78-32-41-860-001-A | Manual Deployment of the Blocker Door |
| TASK 78-32-41-860-002-A | Manual Stowing of the Blocker Door |
Subtask 78-31-00-941-054-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 78-31-00-010-060-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 78-31-00-040-054-A ** ON A/C NOT FOR ALL Subtask 78-31-00-860-072-A ** ON A/C NOT FOR ALL Subtask 78-31-00-081-052-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors: (Ref. AMM TASK 71-13-00-010-040)
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
E. Install the HIX3005 SAFETY SLEEVE - PIVOTING DOOR ACTUATOR on the blocker door actuator (Ref. AMM TASK 78-32-41-480-001)
4. ProcedureSubtask 78-31-00-210-053-A ** ON A/C NOT FOR ALL
A. Do a visual inspection of the primary latch mechanism as follows:
5. Close-up| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| 1.Examine each blocker door latch mechanism for: | | |
| A.Damage | No damage permitted | If you find some damage, replace the door latch. (Ref. AMM TASK 78-31-19-000-001) and (Ref. AMM TASK 78-31-19-400-001). |
| B.Leakage | No leakage permitted | If you find any leakage, examine the supply pipes for the the correct torque (Ref. AMM TASK 78-31-49-400-042), (Ref. AMM TASK 78-31-49-400-043), (Ref. AMM TASK 78-31-49-400-044) and (Ref. AMM TASK 78-31-49-400-045). |
| | | If leakage continues replace the latch (Ref. AMM TASK 78-31-19-000-001) and (Ref. AMM TASK 78-31-19-400-001). |
| 2.Examine the latch hook for: | | |
| A.Damage | No damage permitted | If you find some damage, replace the blocker door latch (Ref. AMM TASK 78-31-19-000-001) and (Ref. AMM TASK 78-31-19-400-001). |
| 3.Examine the latch fitting and roller for: | | |
| A.Damage | No damage permitted | If you find some damage, replace the defective part (Ref. AMM TASK 78-32-41-000-003) and (Ref. AMM TASK 78-32-41-400-003). |
| B.Jamming | The roller must be free to turn | If the roller is not free, remove it (Ref. AMM TASK 78-32-41-000-003) and reinstall it (Ref. AMM TASK 78-32-41-400-003). |
| C.Lubrication | The roller axis must be lubricated | If the roller axis is dry without lubrication, remove the roller (Ref. AMM TASK 78-32-41-000-003), lubricate the axis and install (Ref. AMM TASK 78-32-41-400-003). |
| 4.Examine the parts that attach the latch fitting and roller, look for: | | |
| A.Loose fastener | None permitted | If you find a loose fastener, re-torque the part (Ref. AMM TASK 78-32-41-400-003). |
| B.Missing Fastener | None permitted | If parts are missing replace the missing part. |
Subtask 78-31-00-410-060-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
Subtask 78-31-00-481-052-A ** ON A/C NOT FOR ALL Subtask 78-31-00-860-073-A ** ON A/C NOT FOR ALL Subtask 78-31-00-440-054-A ** ON A/C NOT FOR ALL Subtask 78-31-00-410-061-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.