W DOC AIRBUS | AMM A320F

Check of the Engine Interface Unit (EIU) Internal Memory [PW11]


TASK 73-25-34-860-812-A
Check of the Engine Interface Unit (EIU) Internal Memory


ZONE: 400
1. Reason for the Job
The EIU internal memory needs to be checked to know if the configuration considered by the EIU is the configuration of the aircraft.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-36-00-740-008-A
Access to the Parameter Call-Up Menus
TASK 73-25-34-710-804-A
Engine Interface Unit (EIU) Ground Scanning
3. Job Set-up
Subtask 73-25-34-941-054-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch is in the OFF position.
Subtask 73-25-34-865-120-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENG 1)
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
** ON A/C NOT FOR ALL
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
** ON A/C NOT FOR ALL
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R40
** ON A/C NOT FOR ALL
FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2)
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/FADEC B/AND EIU24KS2Q40
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/FADEC B/AND EIU24KS2R41
4. Procedure
Subtask 73-25-34-280-050-A ** ON A/C NOT FOR ALL
A. Check of the Configuration Stored in the Engine Interface Unit (EIU) Internal Memory
   (1) Do a check of the EIU 1 internal configuration:
NOTE: The actions and the results of this procedure occur on the Multipurpose Control & Display Unit (MCDU) that you use.
     (a) On the EIU 1 output bus:
ACTION
DEFINITION
RESULT
CONFIGURATION
1. On the center pedestal, on SWITCHING panel 8VU, make sure that the EIS DMC selector switch is set to NORM.



2. Get access to the parameter call-up menus, refer to (Ref. AMM TASK 31-36-00-740-008) and enter the parameter-label call-up command that follows:

On the MCDU:

  • 07B/1/032/01
HPP ENG1
  • Start from the right side and make sure that the 7th bit is at 1.
1 = Engine 1 selected
0 = Engine 1 not selected.
  • 07B/1/032/01
HPP ENG2
  • Start from the right side and make sure that the 8th bit is at 0.
1 = Engine 2 selected
0 = Engine 2 not selected.
  • 07B/1/032/01
HPP CFM
  • Start from the right side and make sure that the 9th bit is at 0.
1 = CFM engines selected
0 = CFM engines not selected.
  • 07B/1/032/01
HPP PW
  • Start from the right side and make sure that the 18th bit is at 1.
1 = PW engines selected
0 = PW engines not selected.
     (b) If a failure occurs during the EIU 1 internal configuration-check, do the ground scanning of the EIU (Ref. AMM TASK 73-25-34-710-804) and do the troubleshooting of the failure.
   (2) Do a check of the EIU 2 internal configuration:
NOTE: The actions and the results of this procedure occur on the MCDU that you use.
     (a) On the EIU 2 output bus:
ACTION
DEFINITION
RESULT
CONFIGURATION
1. On the center pedestal, on SWITCHING panel 8VU, make sure that the EIS DMC selector switch is set to NORM.



2. Get access to the parameter call-up menus, refer to (Ref. AMM TASK 31-36-00-740-008) and enter the parameter-label call-up command that follows:

On the MCDU:

  • 07B/2/032/10
HPP ENG1
  • Start from the right side and make sure that the 7th bit is at 0.
1 = Engine 1 selected
0 = Engine 1 not selected.
  • 07B/2/032/10
HPP ENG2
  • Start from the right side and make sure that the 8th bit is at 1.
1 = Engine 2 selected
0 = Engine 2 not selected.
  • 07B/2/032/10
HPP CFM
  • Start from the right side and make sure that the 9th bit is at 0.
1 = CFM engines selected
0 = CFM engines not selected.
  • 07B/2/032/10
HPP PW
  • Start from the right side and make sure that the 18th bit is at 1.
1 = PW engines selected
0 = PW engines not selected.
     (b) If a failure occurs during the EIU 2 internal configuration-check, do the ground scanning of the EIU (Ref. AMM TASK 73-25-34-710-804) and do the troubleshooting of the failure.
5. Close-up
Subtask 73-25-34-942-058-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Put the aircraft back to its initial configuration.
   (2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 13:06:48 UTC