Access to the Parameter Call-Up Menus
TASK 31-36-00-740-008-A
Access to the Parameter Call-Up Menus
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 31-36-00-861-065-A
Subtask 31-36-00-740-056-B ** ON A/C NOT FOR ALL
Subtask 31-36-00-862-065-A
[Rev.10 from 2021]
2026.04.01 00:35:30 UTC
Access to the Parameter Call-Up Menus
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-36-00-00-01 | AIDS INTERCONNECTION (DMU, DAR) - DESCRIPTION AND OPERATION |
| TASK 31-36-00-00-02 | AIDS INTERCONNECTION (DMU, DAR) - DESCRIPTION AND OPERATION |
| TASK 31-37-00-00 | AIDS INPUT INTERFACE - DESCRIPTION AND OPERATION |
Subtask 31-36-00-861-065-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 31-36-00-865-067-A (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | AIDS/DMU | 4TV | K15 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | AIDS & RCDR/FDIMU | 5TV | K15 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | AIDS & RCDR/FDIMU | 5TV | K38 |
Subtask 31-36-00-740-056-B ** ON A/C NOT FOR ALL
A. Access the Parameter Label Call-up Menu through the MCDU
Subtask 31-36-00-740-057-B ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| On the MCDU: | On the MCDU display: |
|
|
|
|
|
|
|
|
|
|
NOTE: The EQ identifier can have 3 characters or only 2 characters, because there are different software versions. NOTE: It is important to enter the DATABITS value if it is other than the default. The decimal value calculation is based on its value. | |
|
NOTE: Two Label Call-up parameters can be displayed at one time. |
|
|
B. Access the Alpha Call-up Menu through the MCDU
Subtask 31-36-00-740-056-C ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| On the MCDU: | On the MCDU display: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C. Access the Parameter Label Call-up Menu through the MCDU
Subtask 31-36-00-740-057-C ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
| On the MCDU: | On the MCDU display: |
|
|
|
|
|
|
|
|
|
|
NOTE: The EQ identifier can have 3 characters or only 2 characters, because there are different software versions. NOTE: It is important to enter the DATABITS value if it is other than the default. The decimal value calculation is based on its value. | |
|
NOTE: Two Label Call-Up parameters can be displayed at one time. |
|
|
D. Access the Alpha Call-up Menu through the MCDU
5. Close-up| ACTION | RESULT |
|---|---|
| On the MCDU: | On the MCDU display: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Subtask 31-36-00-862-065-A
A. Aircraft Maintenance Configuration
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).