W DOC AIRBUS | AMM A320F

Installation of the Fuel Filter Element [PW11]


TASK 73-11-06-400-801-A
Installation of the Fuel Filter Element


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 400
FIN: 2010EM1 ** ON A/C NOT FOR ALL
FIN: 2010EM2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Consumable Materials
REFERENCE
DESIGNATION
(Material No.P03-001)
lubricant, aircraft turbine engine (synthetic base)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR, 452AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR, 462AR
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
3
FUEL FILTER ELEMENT
EIPC 73-11-06-01-100
1
PACKING
EIPC 73-11-06-01-110
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 71-00-00-720-811-A
Test No. 3A - Idle Power Test
TASK 71-00-00-860-833-A
Procedure to Prevent Engine Motoring
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-802-A
Closing of the Fan Cowl Doors
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-30-00-440-805-A
Reactivation of the Thrust Reverser System after Ground Maintenance
TASK 78-36-00-010-802-A
Opening of the Thrust Reverser Cowl-Doors
TASK 78-36-00-410-802-A
Closing of the Thrust Reverser Cowl-Doors
3. Job Set-up
Subtask 73-11-06-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
   (2) Make sure that on the SD ENG fuel page, the LP valve is shown closed.
Subtask 73-11-06-865-051-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENG 1)
49VUFUEL/LP VALVE/MOT1/ENG11QGA08
121VUFUEL/LP VALVE/MOT2/ENG13QGM25
FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2)
49VUFUEL/LP VALVE/MOT1/ENG22QGA09
121VUFUEL/LP VALVE/MOT2/ENG24QGM26
Subtask 73-11-06-010-051-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR
Subtask 73-11-06-040-051-A ** ON A/C NOT FOR ALL
D. Deactivation of the Thrust Reverser System for Ground Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Make sure that you did the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 73-11-06-010-053-A ** ON A/C NOT FOR ALL
E. Get Access
   (1) Make sure that the right thrust-reverser cowl-door is open (Ref. AMM TASK 78-36-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR
4. Procedure
CAUTION: WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE.
Subtask 73-11-06-420-050-A ** ON A/C NOT FOR ALL
A. Installation of the Fuel Filter Element
WARNING: DO NOT GET FUEL IN YOUR MOUTH, EYES OR ON YOUR SKIN. DO NOT BREATHE THE FUMES FROM THE FUEL. KEEP THE FUEL AWAY FROM SPARKS, FLAME AND HEAT. FUEL IS POISONOUS AND FLAMMABLE, WHICH CAN CAUSE INJURIES TO PERSONS AND DAMAGE TO EQUIPMENT.
CAUTION: YOU MUST NOT LET ENGINE FUEL OR OIL FALL ON THE ENGINE. UNWANTED FUEL OR OIL MUST BE REMOVED IMMEDIATELY WITH A CLEAN LINT-FREE CLOTH. THE FUEL OR OIL CAN CAUSE DAMAGE TO THE SURFACE PROTECTION AND TO SOME PARTS.
CAUTION: REMOVE THE PROTECTION COVERS FROM THE OPENINGS AS NECESSARY TO PREVENT ENGINE DAMAGE.
   (1) Make sure that you remove all the necessary COVER - PROTECTION to prevent damage to the engine.
   (2) Install the new EIPC 73-11-06-01-100 FUEL FILTER ELEMENT (3) on the fuel filter housing as follows:
     (a) Apply P03-001lubricant, aircraft turbine engine (synthetic base) to the new EIPC 73-11-06-01-110 PACKING (1) and the two detail packings on the fuel filter element (3).
     (b) Install the packing (1) to the fuel filter housing.
     (c) Install the fuel filter element (3) in the fuel filter housing.
   (3) Installation of the fuel filter bowl (2):
CAUTION: MAKE SURE THAT THE RATCHET LEVER TOUCHES THE FILTER BOWL. IF YOU DO NOT OBEY THIS CAUTION, THE BOWL CAN COME LOOSE AND CAUSE DAMAGE TO THE ENGINE.
     (a) Install and turn the bowl (2) onto the fuel filter housing with your hands only.
     (b) Check the ratchet lever on the housing to make sure it is in contact with the flange of the bowl (2).
NOTE: The latch is an additional safety measure. As long as the ratchet lever touches the bowl, the ratchet lever can be in between two fuel filter bowl teeth. If the bowl were to become loose while the engine is in operation, the lever will catch the next available tooth on the filter bowl.
   (4) Examine the assembly for foreign objects, damage and correct assembly.
5. Close-up
Subtask 73-11-06-410-051-A ** ON A/C NOT FOR ALL
Subtask 73-11-06-440-050-A ** ON A/C NOT FOR ALL
B. Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 73-11-06-410-050-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR
   (2) Remove the WARNING NOTICE(S).
Subtask 73-11-06-865-052-A ** ON A/C NOT FOR ALL
D. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENG 1)
49VUFUEL/LP VALVE/MOT1/ENG11QGA08
121VUFUEL/LP VALVE/MOT2/ENG13QGM25
FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2)
49VUFUEL/LP VALVE/MOT1/ENG22QGA09
121VUFUEL/LP VALVE/MOT2/ENG24QGM26
Subtask 73-11-06-720-050-A ** ON A/C NOT FOR ALL
E. Tests
   (1) Do the test N°3 - Idle power test (Ref. AMM TASK 71-00-00-720-811).
[Rev.10 from 2021] 2026.04.01 07:20:51 UTC