Visual Inspection of Flow Path Panels 1 to 4 [CFML]
TASK 72-24-09-210-801-A
Visual Inspection of Flow Path Panels 1 to 4
This procedure gives the criteria for the visual inspection of flow path panels 1 to 4.
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 72-24-09-941-052-A
Subtask 72-24-09-420-054-A
Subtask 72-24-09-410-052-A
[Rev.10 from 2021]
2026.04.01 13:03:37 UTC
Visual Inspection of Flow Path Panels 1 to 4
ZONE: 400
1. Reason for the JobThis procedure gives the criteria for the visual inspection of flow path panels 1 to 4.
NOTE: The inspection criteria below are applicable after the removal of the high metal.
NOTE: You can use equivalent alternatives for standard tools, equipment and consumable materials.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-803-A | Closing of the Fan Cowl Doors |
| TASK 72-24-09-320-801-A | Kit Engine - Flow Path Panels 1 to 4 - Blending and Spot Touch-up |
| TASK 78-30-00-040-809-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-809-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
| TASK 78-36-00-010-806-A | Opening of the Thrust Reverser Cowl Doors |
| TASK 78-36-00-410-806-A | Closing of the Thrust Reverser Cowl Doors |
Subtask 72-24-09-941-052-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 72-24-09-010-054-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 1M(3 FT) in position.
Subtask 72-24-09-040-052-A (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 1M(3 FT) in position.
C. Deactivation of the Thrust Reverser System for Maintenance
Subtask 72-24-09-010-055-A WARNING:
MAKE THE THRUST REVERSER UNSERVICEABLE (INSTALL AND SAFETY THE ICU LOCKOUT PIN) BEFORE YOU DO WORK ON OR AROUND THE THRUST REVERSER. IF YOU DO NOT INSTALL AND SAFETY THE ICU LOCKOUT PIN, YOU CAN CAUSE ACCIDENTAL OPERATION OF THE THRUST REVERSER AND INJURY TO PERSONS AND/OR DAMAGE TO THE EQUIPMENT.
(1) Do the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-809). D. Get Access
(1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
4. Procedure(1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
Subtask 72-24-09-420-054-A
A. Visual Inspection of Flow Path Panels 1 to 4
5. Close-up| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| 1.Visual inspection of all the areas of flow path panel 1 (1): | | |
| A.Fretting, erosion, wear | Permitted if parent material not visible | See repair (Ref. AMM TASK 72-24-09-320-801). |
| B.Missing OAS | Permitted if no corrosion (white foam) | See repair (Ref. AMM TASK 72-24-09-320-801). |
| C.Dents | Permitted if not more than 0.019 in. (0.48 mm) in depth. Minimum space between two defects must be five times the size of the defect | See repair (Ref. AMM TASK 72-24-09-320-801). |
| D.Nicks, scratches, cracks | Not serviceable | See repair (Ref. AMM TASK 72-24-09-320-801). |
| 2.Visual inspection of all the areas of flow path panel 2 (2): | | |
| A.Fretting, erosion, wear | Permitted if parent material not visible | See repair (Ref. AMM TASK 72-24-09-320-801). |
| B.Missing OAS | Permitted if no corrosion (white foam) | See repair (Ref. AMM TASK 72-24-09-320-801). |
| C.Dents or nicks | Permitted if not more than 0.019 in. (0.48 mm) in depth. Minimum space between two defects must be five times the size of the defect | See repair (Ref. AMM TASK 72-24-09-320-801). |
| D.Scratches or cracks | Permitted if not more than 1 in. (25.4 mm) in length | See repair (Ref. AMM TASK 72-24-09-320-801). |
| 3.Visual inspection of all the areas of flow path panel 3 (3): | | |
| A.Fretting, erosion, wear | Permitted if parent material not visible | See repair (Ref. AMM TASK 72-24-09-320-801). |
| B.Missing OAS | Permitted if no corrosion (white foam) | See repair (Ref. AMM TASK 72-24-09-320-801). |
| C.Dents or nicks | Permitted if not more than 0.019 in. (0.48 mm) in depth. Minimum space between two defects must be five times the size of the defect | See repair (Ref. AMM TASK 72-24-09-320-801). |
| D.Scratches or cracks | Permitted if not more than 1 in. (25.4 mm) in length | See repair (Ref. AMM TASK 72-24-09-320-801). |
| 4.Visual inspection of all the areas of flow path panel 4 (4): | | |
| A.Fretting, erosion, wear | Permitted if parent material not visible | See repair (Ref. AMM TASK 72-24-09-320-801). |
| B.Missing OAS | Permitted if no corrosion (white foam) | See repair (Ref. AMM TASK 72-24-09-320-801). |
| C.Dents | Permitted if not more than 0.019 in. (0.48 mm) in depth. Minimum space between two defects must be five times the size of the defect | See repair (Ref. AMM TASK 72-24-09-320-801). |
| D.Nicks, scratches, cracks | Not serviceable | See repair (Ref. AMM TASK 72-24-09-320-801). |
Subtask 72-24-09-410-052-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
Subtask 72-24-09-440-051-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
B. Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-809).
Subtask 72-24-09-410-053-A
Flow Path Panel 1