Visual Inspection of the Junction Shroud Fitting [CFML]
TASK 72-24-06-210-801-A
Visual Inspection of the Junction Shroud Fitting
This procedure gives the criteria for the visual inspection of the junction shroud fitting.
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 72-24-06-941-052-A
Subtask 72-24-06-420-051-A
Subtask 72-24-06-410-052-A
[Rev.10 from 2021]
2026.04.01 13:04:02 UTC
Visual Inspection of the Junction Shroud Fitting
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the JobThis procedure gives the criteria for the visual inspection of the junction shroud fitting.
NOTE: The inspection criteria below are applicable after the removal of the high metal.
NOTE: You can use equivalent alternatives for standard tools, equipment and consumable materials.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-803-A | Closing of the Fan Cowl Doors |
| TASK 72-24-06-000-801-A | Removal of the Shroud Junction Fitting |
| TASK 72-24-06-400-801-A | Installation of the Shroud Junction Fitting |
| TASK 78-30-00-040-809-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-809-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
| TASK 78-36-00-010-806-A | Opening of the Thrust Reverser Cowl Doors |
| TASK 78-36-00-410-806-A | Closing of the Thrust Reverser Cowl Doors |
Subtask 72-24-06-941-052-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 72-24-06-010-054-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 1M(3 FT) in position.
Subtask 72-24-06-040-052-A (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 1M(3 FT) in position.
C. Deactivation of the Thrust Reverser System for Maintenance
Subtask 72-24-06-010-055-A WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Do the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-809). D. Get Access
(1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
4. Procedure(1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
Subtask 72-24-06-420-051-A
A. Visual Inspection of the Junction Shroud Fitting on the Exposed Area
(1) Do a visual inspection of all the areas of the axial junction shroud fitting. Refer to the table below for the inspection area.
5. Close-up(1) Do a visual inspection of all the areas of the axial junction shroud fitting. Refer to the table below for the inspection area.
| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| 1. Visual inspection of all the areas of the axial junction shroud fitting (1) | | |
| A. Fretting, erosion, wear | PRE SB72-0232 - Any amount, if dimension C is between 0.193 in. (4.9 mm) and 0.201 in. (5.1 mm). - Any amount, if dimension D is between 0.193 in. (4.9 mm) and 0.201 in. (5.1 mm). END PRE SB72-0232 POST SB72-0232 Not serviceable END POST SB72-0232 | Replace the axial junction shroud fitting (1) (Ref. AMM TASK 72-24-06-000-801) and (Ref. AMM TASK 72-24-06-400-801). |
| 2. Visual inspection of area D (all areas except area E) | | |
| A. Dents | PRE SB72-0232 Permitted, if not more than 0.023 in. (0.6 mm) in depth. END PRE SB72-0232 POST SB72-0232 Not serviceable END POST SB72-0232 | |
| 3. Visual inspection of area E | | |
| A. Dents | Not serviceable | Replace the axial junction shroud fitting (1) (Ref. AMM TASK 72-24-06-000-801) and (Ref. AMM TASK 72-24-06-400-801). |
| 4. Visual inspection of area F (all areas except area G) | | |
| A. Nicks, scratches, cracks | Not serviceable | Replace the axial junction shroud fitting (1) (Ref. AMM TASK 72-24-06-000-801) and (Ref. AMM TASK 72-24-06-400-801). |
| 5. Visual inspection of area G | | |
| A. Nicks, scratches, cracks | PRE SB72-0232 Permitted, if not more than 0.023 in. (0.6 mm) in depth. END PRE SB72-0232 POST SB72-0232 Not serviceable END POST SB72-0232 | |
| 6. Visual inspection of the replaceable nuts (2) | | |
| A. Missing | Not serviceable | PRE SB72-0232 See repair (Ref. AMM D/O 72-24-06-96). END PRE SB72-0232 |
| B. Looseness | Not serviceable | PRE SB72-0232 See repair (Ref. AMM D/O 72-24-06-96). END PRE SB72-0232 |
| C. Damage | Not serviceable | PRE SB72-0232 See repair (Ref. AMM D/O 72-24-06-96). END PRE SB72-0232 |
| 7. Visual inspection of the seal (3) | | |
| A. Missing | Not serviceable | |
| B. Looseness | Not serviceable | |
| C. Break, crack, scratch, color change | Not serviceable | |
| D. Bubbles | Not serviceable | |
| E. Permanent strain, excessive strain | Not serviceable | |
| 8. Visual inspection of all the areas of the junction shroud fitting (4) | | |
| A. Fretting, galling, erosion, wear | PRE SB72-0232 Any amount, if dimension E is between 0.193 in. (4.9 mm) and 0.201 in. (5.1 mm). END PRE SB72-0232 POST SB72-0232 Not serviceable END POST SB72-0232 | |
| 9. Visual inspection of area H (all the areas except area J) | | |
| A. Dents | PRE SB72-0232 Permitted, if not more than 0.023 in. (0.6 mm) in depth. END PRE SB72-0232 POST SB72-0232 Not serviceable END POST SB72-0232 | |
| 10. Visual inspection of area J | | |
| A. Dents | Not serviceable | Replace the junction shroud fitting (4) (Ref. AMM TASK 72-24-06-000-801) and (Ref. AMM TASK 72-24-06-400-801). |
| 11. Visual inspection of area K | | |
| A. Nicks, scratches, cracks | Not serviceable | Replace the junction shroud fitting (4) (Ref. AMM TASK 72-24-06-000-801) and (Ref. AMM TASK 72-24-06-400-801). |
| 12. Visual inspection of area L | | |
| A. Nicks, scratches, cracks | PRE SB72-0232 Permitted, if not more than 0.023 in. (0.6 mm) in depth. END PRE SB72-0232 POST SB72-0232 Not serviceable END POST SB72-0232 | |
| 13. Visual inspection of the replaceable nuts (5) | | |
| A. Missing | Not serviceable | PRE SB72-0232 See repair (Ref. AMM D/O 72-24-06-96). END PRE SB72-0232 |
| B. Looseness | Not serviceable | PRE SB72-0232 See repair (Ref. AMM D/O 72-24-06-96). END PRE SB72-0232 |
| C. Damage | Not serviceable | PRE SB72-0232 See repair (Ref. AMM D/O 72-24-06-96). END PRE SB72-0232 |
| 14. Visual inspection of the seal (6) | | |
| A. Missing | Not serviceable | |
| B. Looseness | Not serviceable | |
| C. Break, crack, scratch, color change | Not serviceable | |
| D. Bubbles | Not serviceable | |
| E. Permanent strain, excessive strain | Not serviceable | |
Subtask 72-24-06-410-052-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
Subtask 72-24-06-440-051-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
B. Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-809).
Subtask 72-24-06-410-053-A
The Axial Junction Shroud Fitting - PRE SB72-0232