Special Detailed Inspection (ENDOSCOPE) of Pylon, Lower Spar, Upper Surface, between RIB 1 and RIB 2, and RIB 3 and RIB 4, and RIB 8 and RIB 10
TASK 54-51-00-200-028-A
Special Detailed Inspection (ENDOSCOPE) of Pylon, Lower Spar, Upper Surface, between RIB 1 and RIB 2, and RIB 3 and RIB 4, and RIB 8 and RIB 10
Refer to the MPD TASK: 545104-02
SPECIAL DETAILED INSPECTION (ENDOSCOPE) OF PYLON, LOWER SPAR, UPPER SURFACE, BETWEEN RIB 1 AND RIB 2, AND RIB 3 AND RIB 4, AND RIB 8 AND RIB 10.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 54-51-00-941-055-A ** ON A/C NOT FOR ALL
Subtask 54-51-00-250-052-A ** ON A/C NOT FOR ALL
Subtask 54-51-00-440-056-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 01:59:27 UTC
Special Detailed Inspection (ENDOSCOPE) of Pylon, Lower Spar, Upper Surface, between RIB 1 and RIB 2, and RIB 3 and RIB 4, and RIB 8 and RIB 10
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
CAUTION:
DO NOT APPLY TEMPORARY PROTECTION SYSTEM (TPS) ON THE INSPECTION AREA. IF YOU APPLY TPS ON THE INSPECTION AREA, YOU CAN CAUSE DAMAGE TO THE AIRCRAFT.
1. Reason for the JobRefer to the MPD TASK: 545104-02
SPECIAL DETAILED INSPECTION (ENDOSCOPE) OF PYLON, LOWER SPAR, UPPER SURFACE, BETWEEN RIB 1 AND RIB 2, AND RIB 3 AND RIB 4, AND RIB 8 AND RIB 10.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 415 | LOWER PYLON |
| 425 | LOWER PYLON |
| 415AL, 415AR, 415BL, 415BR, 425AL, 425AR, 425BL, 425BR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 51-78-00-916-001-A | Application of Temporary Protection System (TPS) |
| TASK 54-51-21-000-001-A | Removal of the Pylon Lateral Access-Doors |
| TASK 54-51-21-400-001-A | Installation of the Pylon Lateral Access-Doors |
| TASK 78-30-00-040-012-A | Deactivation of the Thrust Reverser Hydraulic Control Unit (HCU) for Ground Maintenance |
| TASK 78-30-00-081-041-A | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-081-041-B | Make the Thrust Reverser Serviceable after Maintenance |
| TASK 78-30-00-440-012-A | Re-activation of the Thrust Reverser Hydraulic Control Unit (HCU) after Ground Maintenance |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-30-00-481-041-B | Make the Thrust Reverser Unserviceable for Maintenance |
| NTM 545104 | |
| SRM 51110000 | (for corrective action) |
| SRM 51110001 | (for corrective action) |
| SRM 51220000 | (for corrective action) |
| SRM 51220001 | (for corrective action) |
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL | |
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL | |
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL | |
Subtask 54-51-00-941-055-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC.
Subtask 54-51-00-010-054-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC.
B. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position:
(a) At zone 470 for the left pylon
(b) At zone 480 for the right pylon.
(2) Remove the pylon lateral access-doors (Ref. AMM TASK 54-51-21-000-001):
(a) For the left pylon: 415AL 415AR 415BL 415BR
(b) For the right pylon: 425AL 425AR 425BL 425BR.
Subtask 54-51-00-040-056-A ** ON A/C NOT FOR ALL (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position:
(a) At zone 470 for the left pylon
(b) At zone 480 for the right pylon.
(2) Remove the pylon lateral access-doors (Ref. AMM TASK 54-51-21-000-001):
(a) For the left pylon: 415AL 415AR 415BL 415BR
(b) For the right pylon: 425AL 425AR 425BL 425BR.
C. Aircraft Maintenance Configuration
(1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
Subtask 54-51-00-040-056-B ** ON A/C NOT FOR ALL (1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-481-041).
C. Aircraft Maintenance Configuration
(1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-040-012).
Subtask 54-51-00-110-056-A ** ON A/C NOT FOR ALL (1) Make the thrust reverser unserviceable (Ref. AMM TASK 78-30-00-040-012).
D. Preparation of the Inspection Area
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL
(1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
(2) If it is not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Make sure that there is no Temporary Protection System (TPS) layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
(4) Do a visual check of the inspection area for damage or discontinuities.
(5) Make sure that there is no:
(a) Corrosion damage:
4. Procedure
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL (2) If it is not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and a Textile-Lint free Cotton - (Material No.14SBA1) .
(3) Make sure that there is no Temporary Protection System (TPS) layer and if there is a TPS layer, remove it (Ref. AMM TASK 51-78-00-916-001).
(4) Do a visual check of the inspection area for damage or discontinuities.
(5) Make sure that there is no:
(a) Corrosion damage:
- If you find corrosion damage, refer to the Structural Repair Manual SRM 51220001 for types of corrosion, inspection, removal and corrosion protection.
- If you find this type of damage, refer to the Structural Repair Manual SRM 51110001 for damage classification and corrective action.
Subtask 54-51-00-250-052-A ** ON A/C NOT FOR ALL
A. Inspection
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL
(1) Do a special detailed inspection of the upper surface of the pylon lower spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10. Refer to the Non-destructive Testing Manual NTM 545104.
(2) Make a report of damage after NDT inspection:
(a) Corrosion damage:
5. Close-up
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL
Lower Spar between RIB1 and RIB2, RIB3 and RIB4, and RIB8 and RIB10 - Inspection Areas ** ON A/C NOT FOR ALL (2) Make a report of damage after NDT inspection:
(a) Corrosion damage:
- If you find corrosion damage, refer to the Structural Repair Manual SRM 51220000 for types of corrosion, inspection, removal and corrosion protection.
- If you find this type of damage, refer to the Structural Repair Manual SRM 51110000 for damage classification and corrective action.
Subtask 54-51-00-440-056-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
Subtask 54-51-00-440-056-B ** ON A/C NOT FOR ALL (1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-081-041).
A. Aircraft Maintenance Configuration
(1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-440-012).
Subtask 54-51-00-410-055-A ** ON A/C NOT FOR ALL (1) Make the thrust reverser serviceable (Ref. AMM TASK 78-30-00-440-012).
B. Close Access
(1) Install the pylon lateral access-doors (Ref. AMM TASK 54-51-21-400-001):
(a) For the left pylon: 415AL 415AR 415BL 415BR
(b) For the right pylon: 425AL 425AR 425BL 425BR.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).
(1) Install the pylon lateral access-doors (Ref. AMM TASK 54-51-21-400-001):
(a) For the left pylon: 415AL 415AR 415BL 415BR
(b) For the right pylon: 425AL 425AR 425BL 425BR.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the access platform(s).
(4) Remove the WARNING NOTICE(S).