W DOC AIRBUS | AMM A320F

Access to the Data Memory Module (DMM) Report (131-9(A))


TASK 49-00-00-970-001-A
Access to the Data Memory Module (DMM) Report (131-9(A))


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-001-A
Procedure to Get Access to the SYSTEM REPORT/TEST Menu Page
3. Job Set-up
Subtask 49-00-00-861-063-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
Subtask 49-00-00-865-134-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
Subtask 49-00-00-860-135-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) On the overhead panel push the APU MASTER SW p/bsw (the blue ON legend comes on).
   (2) Do the procedure to get the SYSTEM/REPORT TEST item APU (Ref. AMM TASK 31-32-00-860-001).
4. Procedure
Subtask 49-00-00-970-050-A ** ON A/C NOT FOR ALL
A. Get access to the DMM data
ACTION
RESULT
1.On the MCDU:
On the MCDU display:
  • push the line key adjacent to the APU indication.
  • the APU page comes on.
  • push the NEXT page p/bsw.

  • push the line key adjacent to the SERVICE DATA indication.
  • the SERVICE DATA page comes on.
  • push the line key adjacent to the DMM indication.
  • the DMM DATA page comes on.
5. Close-up
Subtask 49-00-00-860-136-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) On the overhead panel push the APU MASTER SW p/bsw (the blue ON legend goes off).
   (2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).