Operational Test of the Waste/Water Drain System
TASK 38-32-00-710-002-A
Operational Test of the Waste/Water Drain System
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-32-00-861-051-A Subtask 38-32-00-010-050-A
Subtask 38-32-00-710-051-A ** ON A/C NOT FOR ALL
Subtask 38-32-00-613-053-A Subtask 38-32-00-410-054-A
[Rev.10 from 2021]
2026.04.01 04:27:17 UTC
Operational Test of the Waste/Water Drain System
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE |
| No specific | AR | CONTAINER 20L (5 USGAL) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | VALVE - SHUT OFF |
| 98D38108002000 | AR | ADAPTER DRAIN MAST |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 130 | FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX |
| 150 | AFT CARGO COMPARTMENT FWD PRESS BULKHEAD TO AFT BULKHEAD OF AFT CARGO COMPARTMENT |
| 170 | AFT CAB U/FLOOR COMPT AFT BHD OF BULK |
| 220 | FWD CAB UTILITY AREAS |
| 250 | AFT PASSENGER COMPARTMENT |
| 260 | AFT CABIN UTILITY AREA |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-15-38-613-001-A | Fill the Potable Water Tank System (Aircraft Electrical Power Available) |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-41-00-00 | FORWARD LAVATORIES - DESCRIPTION AND OPERATION |
| TASK 25-43-00-00 | AFT LAVATORIES - DESCRIPTION AND OPERATION |
Subtask 38-32-00-861-051-A Subtask 38-32-00-010-050-A
B. Get Access
(1) Open the applicable lavatory door (Ref. AMM D/O 25-41-00-00) or (Ref. AMM D/O 25-43-00-00).
Subtask 38-32-00-865-054-A (1) Open the applicable lavatory door (Ref. AMM D/O 25-41-00-00) or (Ref. AMM D/O 25-43-00-00).
C. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 38-32-00-865-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WATER SYSTEM-QANT-IND | 1MA | B01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-QUANT-IND | 1MA | B06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-DRAIN | 1MP | B05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER-SYS-DRAIN | 1MP | B05 |
D. Open, safety and tag this(these) circuit breaker(s):
Subtask 38-32-00-860-054-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WASTE WIP-DRAINMAST-FWD | 1DU | B06 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DRAINMAST-FWD | 1DU | B03 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WASTE WIP-DRAINMAST-FWD | 1DU | B03 |
| ** ON A/C ALL | |||
| 2001VU | WASTE WIP-DRAINMAST-AFT | 11DU | E01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WASTE WIP-DRAINMAST-MID | 21DU | E02 |
E. Preparation for the Test
(1) Fill the potable water system (Ref. AMM TASK 12-15-38-613-001).
(2) If you do work on the aft drain mast, put an ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in the correct position.
(3) Install a hose with a VALVE - SHUT OFF in the related drain mast.
(5) Close the shutoff valve assembly at the drain mast.
4. Procedure(1) Fill the potable water system (Ref. AMM TASK 12-15-38-613-001).
(2) If you do work on the aft drain mast, put an ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in the correct position.
(3) Install a hose with a VALVE - SHUT OFF in the related drain mast.
NOTE: You can use an 98D38108002000 ADAPTER DRAIN MAST as an alternative to the VALVE - SHUT OFF.
(4) Put the open end of the hose in a CONTAINER 20L (5 USGAL). (5) Close the shutoff valve assembly at the drain mast.
Subtask 38-32-00-710-051-A ** ON A/C NOT FOR ALL
A. Do this test:
Subtask 38-32-00-710-051-B ** ON A/C NOT FOR ALL NOTE: This procedure is applicable only for the drain assembly that has a stopper.
| ACTION | RESULT |
|---|---|
1.In the lavatory:
| In the lavatory:
|
2.At the drain mast:
| At the drain mast:
|
3.At the drain mast:
| |
4.In the lavatory:
| |
5.In the lavatory:
| In the lavatory:
|
6.In the lavatory:
| In the lavatory:
|
7.In the lavatory:
| In the lavatory:
|
8.At the drain mast:
| In the lavatory:
|
A. Do this test:
5. Close-upNOTE: This procedure is applicable only for the drain assembly that has a drain plug.
| ACTION | RESULT |
|---|---|
1.In the lavatory:
| In the lavatory:
|
2.At the drain mast:
| At the drain mast:
|
3.At the drain mast:
| |
4.In the lavatory:
| |
5.In the lavatory:
| In the lavatory:
|
6.In the lavatory:
| In the lavatory:
|
7.In the lavatory:
| In the lavatory:
|
8.At the drain mast:
| In the lavatory:
|
Subtask 38-32-00-613-053-A Subtask 38-32-00-410-054-A
B. Close Access
(1) Remove the hose and the VALVE - SHUT OFF.
(2) If the 98D38108002000 ADAPTER DRAIN MAST is installed, remove it.
(3) Remove the CONTAINER 20L (5 USGAL).
(4) Remove the access platform(s).
(5) Make sure that the work area is clean and clear of tools and other items.
(6) Close the applicable lavatory door (Ref. AMM D/O 25-41-00-00) or (Ref. AMM D/O 25-43-00-00).
Subtask 38-32-00-865-052-A (1) Remove the hose and the VALVE - SHUT OFF.
(2) If the 98D38108002000 ADAPTER DRAIN MAST is installed, remove it.
(3) Remove the CONTAINER 20L (5 USGAL).
(4) Remove the access platform(s).
(5) Make sure that the work area is clean and clear of tools and other items.
(6) Close the applicable lavatory door (Ref. AMM D/O 25-41-00-00) or (Ref. AMM D/O 25-43-00-00).
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 38-32-00-862-051-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WASTE WIP-DRAINMAST-FWD | 1DU | B06 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | DRAINMAST-FWD | 1DU | B03 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WASTE WIP-DRAINMAST-FWD | 1DU | B03 |
| ** ON A/C ALL | |||
| 2001VU | WASTE WIP-DRAINMAST-AFT | 11DU | E01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WASTE WIP-DRAINMAST-MID | 21DU | E02 |