W DOC AIRBUS | AMM A320F

Operational Test of the Quantity Indicating System


TASK 38-13-00-710-001-A
Operational Test of the Quantity Indicating System


ZONE: 170
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
No specific
1
CART - SERVICING, WATER, POTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
170
AFT CAB U/FLOOR COMPT AFT BHD OF BULK
171AL
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 12-24-38-680-001-A
Draining of the Potable Water System (with Electrical Power)
TASK 12-24-38-680-002-A
Draining of the Potable Water System (without Electrical Power)
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
3. Job Set-up
Subtask 38-13-00-861-050-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 38-13-00-860-050-A
B. Preparation for Test
   (1) Put an ACCESS PLATFORM 2M (6 FT) in position below potable-water service door 171AL.
   (2) Open potable-water service door 171AL.
   (3) Drain the potable water tank (Ref. AMM TASK 12-24-38-680-001) or (Ref. AMM TASK 12-24-38-680-002).
   (4) Connect the CART - SERVICING, WATER, POTABLE to the fill connection at service panel 2023VU.
Subtask 38-13-00-865-052-A
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUWATER SYSTEM-QANT-IND1MAB01
** ON A/C NOT FOR ALL
2001VUWATER SYS-QUANT-IND1MAB06
** ON A/C NOT FOR ALL
2001VUWATER SYS-DRAIN1MPB05
** ON A/C NOT FOR ALL
2001VUWATER-SYS-DRAIN1MPB05
4. Procedure
Subtask 38-13-00-710-050-B ** ON A/C NOT FOR ALL
A. Do this test.
ACTION
RESULT
1.At service panel 2023VU:
  • Put the fill and drain handle to the FILL position.
At service panel 2023VU:
  • Fill/drain valve 16MA opens.

  • The overflow-valve control light comes on.
  • Fill the potable water tank with 50.0 l (13.21 USgal) of water.
  • Quantity indicator 6MA shows 1/4 full.

On Forward Attendant Panel (FAP) 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • Quantity indicator shows 25%.
2.At service panel 2023VU:
  • Push and hold door limit switch 5MA.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • There is no indication.
3.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • Push and hold the membrane switch 'IND ON'.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • The quantity indicator shows 25%.
4.At service panel 2023VU:
  • Fill the potable water tank with 100.0 l (26.42 USgal) of water.
At service panel 2023VU:
  • Quantity indicator 6MA shows 1/2 full.

On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • Quantity indicator shows 50% full.
5.At service panel 2023VU:
  • Push and hold door limit switch 5MA.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • There is no indication.
6.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • Push and hold the membrane switch 'IND ON'.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • The quantity indicator shows 50%.
7.At service panel 2023VU:
  • Fill the potable water tank with 150.0 l (39.63 USgal) of water.
At service panel 2023VU:
  • Quantity indicator 6MA shows 3/4 full.

On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • The quantity indicator shows 75% full.
8.At service panel 2023VU:
  • Push and hold door limit switch 5MA.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • There is no indication.
9.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • Push and hold the membrane switch 'IND ON'.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • The quantity indicator shows 75%.
10.At service panel 2023VU:
  • Fill the potable water tank with 200 l (52.83 USgal) of water.
At service panel 2023VU:
  • Quantity indicator 6MA shows full.
  • Motorized fill/drain valve 16MA closes.
  • The TANK FULL control light comes on.
  • The overflow-valve control light goes off.
  • The fill and drain handle goes back to the NORMAL position.

On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • The quantity indicator shows 100% full.
11.At service panel 2023VU:
  • Push and hold door limit switch 5MA.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • There is no indication.
12.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • Push and hold the membrane switch 'IND ON'.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • The quantity indicator shows 100%.
Subtask 38-13-00-710-050-D ** ON A/C NOT FOR ALL
A. Do this test.
ACTION
RESULT
1.At service panel 2023VU:

  • Open the Potable Water Service Panel (PWSP) door.
At the Flight Attendant Panel (FAP) 124RH:
  • The SERVICE DOOR OPEN message is shown.
  • No fail messages are shown on the WATER/WASTE page.
2.On the FAP:
  • Push the Water/Waste key to get the WATER/WASTE page.
On the FAP:
  • The WATER/WASTE page comes into view.
3.On the WATER/WASTE page:
  • Close the PWSP door at service panel 2023VU.
  • Push the preselection key on the WATER/WASTE page.
ON the WATER/WASTE page:
  • The preselection key change to green.
  • The PRESELECTED QUANTITY box comes into view.
4.At service panel 2023VU:
  • Turn and pull the fill and drain handle to the FILL Position.
At service panel 2023VU:
  • Motorized fill/overflow/drain valve 8MA opens.
5.On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
  • Push the upper arrow (+) to '25%'.
On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
  • '25%' is shown in the window.
6.At service panel 2023VU:
  • Fill the potable water tank with 50 l (13.21 USgal) of water.
At service panel 2023VU:
  • Motorized fill/overflow/drain valve 8MA closes.
  • The TANK FULL control light comes on.
  • The fill and drain handle goes back to the NORMAL position.

On the FAP, WATER/WASTE page:
  • '25%' is shown on the PRESELECTED QUANTITY box.
  • '25%' is shown on the potable-water tank symbol.
7.On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
  • Push the upper arrow (+) to '50%'.
On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
  • '50%' is shown in the window.
8.At service panel 2023VU:
  • Turn and pull the fill and drain handle to the FILL position.
At service panel 2023VU:
  • Motorized fill/overflow/drain valve 8MA opens.
9.At service panel 2023VU:
  • Fill the potable water tank with 100 l (26.42 USgal) of water.
At service panel 2023VU:
  • Motorized fill/overflow/drain valve 8MA closes.
  • The TANK FULL control light comes on.
  • The fill and drain handle goes back to the NORMAL position.

On the FAP, WATER/WASTE page:
  • '50%' is shown on the PRESELECTED QUANTITY box.
  • '50%' is shown on the potable-water tank symbol.
10.On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
  • Push the upper arrow (+) to '75%'.
On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
  • '75%' is shown in the window.
11.At service panel 2023VU:
  • Turn and pull the fill and drain handle to the FILL position.
At service panel 2023VU:
  • Motorized fill/overflow/drain valve 8MA opens.
12.At service panel 2023VU:
  • Fill the potable water tank with 150 l (39.63 USgal) of water.
At service panel 2023VU:
  • Motorized fill/overflow/drain valve 8MA closes.
  • The TANK FULL control light comes on.
  • The fill and drain handle goes back to the NORMAL position.

On the FAP, WATER/WASTE page:
  • '75%' is shown on the PRESELECTED QUANTITY box.
  • '75%' is shown on the potable-water tank symbol.
13.On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
  • Push the upper arrow (+) to '100%'.
On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
  • '100%' is shown in the window.
14.At service panel 2023VU:
  • Turn and pull the fill and drain handle to the FILL position.
At service panel 2023VU:
  • Motorized fill/overflow/drain valve 8MA opens.
15.At service panel 2023VU:
  • Fill the potable water tank with 200 l (52.83 USgal) of water.
At service panel 2023VU:
  • Motorized fill/overflow/drain 8MA closes.
  • The TANK FULL control light comes on.
  • The fill and drain handle goes back to the NORMAL position.

On the FAP, WATER/WASTE page:
  • '100%' is shown on the PRESELECTED QUANTITY box.
  • '100%' is shown on the potable-water tank symbol.
16.At service panel 2023VU:
  • Push and hold the door limit switch 5MA.
At service panel 2023VU:
  • The TANK FULL control light goes off.

At the Flight Attendant Panel (FAP) 124RH:
  • The SERVICE DOOR OPEN message is not shown.
Subtask 38-13-00-710-050-K ** ON A/C NOT FOR ALL
A. Do this test.
ACTION
RESULT
1.At service panel 2023VU:
  • Put the fill and drain handle to the FILL position.
At service panel 2023VU:
  • Fill the potable water tank with 55.0 l (14.53 USgal) of water.
  • Quantity indicator 6MA shows 1/4 full.

At Forward Attendant Panel (FAP) 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • The quantity indicator shows 25% full.
2.At service panel 2023VU:
  • Push and hold door limit switch 5MA.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • There is no indication.
3.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • Push and hold the membrane switch 'IND ON'.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • The quantity indicator shows 25% full.
4.At service panel 2023VU:
  • Fill the potable water tank with 110.0 l (29.06 USgal) of water.
At service panel 2023VU:
  • Quantity indicator 6MA shows 1/2 full.

On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • The quantity indicator shows 50% full.
5.At service panel 2023VU:
  • Push and hold door limit switch 5MA.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • There is no indication.
6.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • Push and hold the membrane switch 'IND ON'.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • The quantity indicator shows 50% full.
7.At service panel 2023VU:
  • Fill the potable water tank with 165.0 l (43.59 USgal) of water.
At service panel 2023VU:
  • Quantity indicator 6MA shows 3/4 full.

On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • The quantity indicator shows 75% full.
8.At service panel 2023VU:
  • Push and hold door limit switch 5MA.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • There is no indication.
9.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • Push and hold the membrane switch 'IND ON'.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • The quantity indicator shows 75% full.
10.At service panel 2023VU:
  • Fill the potable water tank with 220 l (58.12 USgal) of water.
At service panel 2023VU:
  • Motorized fill/overflow/drain valve 8MA closes.
  • The TANK FULL control light comes on.
  • Quantity indicator 6MA shows full.
  • The fill and drain handle goes back to the NORMAL position.

On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • The quantity indicator shows 100% full.
11.At service panel 2023VU:
  • Push and hold door limit switch 5MA.
At service panel 2023VU:
  • The TANK FULL control light goes off.

On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • There is no indication.
12.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • Push and hold the membrane switch 'IND ON'.
On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
  • The quantity indicator shows 100% full.
Subtask 38-13-00-710-050-P ** ON A/C NOT FOR ALL
A. Test(s)
   (1) Do the test that follows:
ACTION
RESULT
1.At service panel 2023VU:

  • Open the Potable Water Service Panel (PWSP) door.
At Flight Attendant Panel (FAP) 120RH:

  • The SERVICE DOOR OPEN message is shown.
  • No fail messages are shown on the WATER/WASTE page.
2.On the FAP:
  • Push the Water/Waste key to get the WATER/WASTE page.
On the FAP:
  • The WATER/WASTE page comes into view.
3.At service panel 2023VU:
  • Turn and pull the fill and drain handle to the FILL position.
At service panel 2023VU:
  • Fill/overflow drain valve 8MA opens.
  • The overflow-valve control light comes on.
4.At service panel 2023VU:
  • Fill the potable water tank with 50 l (13.21 USgal) of water.
At service panel 2023VU:
  • Quantity indicator 6MA shows 1/4 full.

On the FAP, on the WATER/WASTE page:
  • '25%' is shown on the potable-water tank symbol.
5.At service panel 2023VU:
  • Fill the potable water tank with 100 l (26.42 USgal) of water.
At service panel 2023VU:
  • Quantity indicator 6MA shows 1/2 full.

On the FAP, on the WATER/WASTE page:
  • '50%' is shown on the potable-water tank symbol.
6.At service panel 2023VU:
  • Fill the potable water tank with 150 l (39.63 USgal) of water.
At service panel 2023VU:
  • Quantity indicator 6MA shows 3/4 full.

On the FAP, on the WATER/WASTE page:
  • '75%' is shown on the potable-water tank symbol.
7.At service panel 2023VU:
  • Fill the potable water tank with 200 l (52.83 USgal) of water.
At service panel 2023VU:
  • Quantity indicator 6MA shows full.
  • Fill/overflow drain valve 8MA closes.
  • The TANK FULL control light comes on.
  • The overflow-valve control light goes off.
  • The fill and drain handle goes back to the NORMAL position.

On the FAP, on the WATER/WASTE page:
  • '100%' is shown on the potable-water tank symbol.
8.At service panel 2023VU:
  • Push and hold door limit switch 5MA.
At service panel 2023VU:
  • The TANK FULL control light goes off.

At FAP 120RH:
  • The SERVICE DOOR OPEN message is not shown.
Subtask 38-13-00-710-050-S ** ON A/C NOT FOR ALL
A. Test(s)
   (1) Do the test that follows:
ACTION
RESULT
1.At service panel 2023VU:

  • Open the Potable Water Service Panel (PWSP) door.
At Flight Attendant Panel (FAP) 120RH:

  • The SERVICE DOOR OPEN message is shown.
  • No fail messages are shown on the WATER/WASTE page.
2.On the FAP:
  • Push the Water/Waste key to get the WATER/WASTE page.
On the FAP:
  • The WATER/WASTE page comes into view.
3.At service panel 2023VU:
  • Make sure that the potable water tank is drained.
At service panel 2023VU:
  • The orange 'E' LED on quantity indicator 6MA is on.

On the FAP, on the WATER/WASTE page:
  • '0%' is shown on the potable-water tank symbol.
4.At service panel 2023VU:
  • Turn and pull the fill/overflow drain handle to the FILL position.
At service panel 2023VU:
  • Fill/overflow drain valve 16MA opens.
  • The overflow-valve control light comes on.
5.At service panel 2023VU:
  • Fill the potable water tank with 50 l (13.21 USgal) of water.
At service panel 2023VU:
  • The blue '1/4' LED on quantity indicator 6MA comes on.

On the FAP, on the WATER/WASTE page:
  • '25%' is shown on the potable-water tank symbol.
6.At service panel 2023VU:
  • Fill the potable water tank with 100 l (26.42 USgal) of water.
At service panel 2023VU:
  • The blue '1/2' LED on quantity indicator 6MA comes on.

On the FAP, on the WATER/WASTE page:
  • '50%' is shown on the potable-water tank symbol.
7.At service panel 2023VU:
  • Fill the potable water tank with 150 l (39.63 USgal) of water.
At service panel 2023VU:
  • The blue '3/4' LED on quantity indicator 6MA comes on.

On the FAP, on the WATER/WASTE page:
  • '75%' is shown on the potable-water tank symbol.
8.At service panel 2023VU:
  • Fill the potable water tank with 200 l (52.83 USgal) of water.
At service panel 2023VU:
  • The blue 'F' LED on quantity indicator 6MA comes on.
  • Fill/overflow drain valve 16MA closes.
  • The TANK FULL control light comes on.
  • The overflow-valve control light goes off.
  • The fill/overflow drain handle goes back to the NORMAL position.

On the FAP, on the WATER/WASTE page:
  • '100%' is shown on the potable-water tank symbol.
9.At service panel 2023VU:
  • Push and hold door limit switch 5MA.
At service panel 2023VU:
  • The TANK FULL control light goes off.

At FAP 120RH:
  • The SERVICE DOOR OPEN message is not shown.
Subtask 38-13-00-710-050-T ** ON A/C NOT FOR ALL
A. Test(s)
   (1) Do the test that follows:
ACTION
RESULT
1.At service panel 2023VU:

  • Open the Potable Water Service Panel (PWSP) door.
At Flight Attendant Panel (FAP) 120RH:

  • The SERVICE DOOR OPEN message is shown.
  • No fail messages are shown on the WATER/WASTE page.
2.On the FAP:
  • Push the Water/Waste key to get the WATER/WASTE page.
On the FAP:
  • The WATER/WASTE page comes into view.
3.At service panel 2023VU:
  • Make sure that the potable water tank is drained.
At service panel 2023VU:
  • The orange 'E' LED on quantity indicator 6MA is on.

On the FAP, on the WATER/WASTE page:
  • '0%' is shown on the potable-water tank symbol.
4.At service panel 2023VU:
  • Turn and pull the fill/overflow drain handle to the FILL position.
At service panel 2023VU:
  • Fill/overflow drain valve 8MA opens.
  • The overflow-valve control light comes on.
5.At service panel 2023VU:
  • Fill the potable water tank with 50 l (13.21 USgal) of water.
At service panel 2023VU:
  • The blue '1/4' LED on quantity indicator 6MA comes on.

On the FAP, on the WATER/WASTE page:
  • '25%' is shown on the potable-water tank symbol.
6.At service panel 2023VU:
  • Fill the potable water tank with 100 l (26.42 USgal) of water.
At service panel 2023VU:
  • The blue '1/2' LED on quantity indicator 6MA comes on.

On the FAP, on the WATER/WASTE page:
  • '50%' is shown on the potable-water tank symbol.
7.At service panel 2023VU:
  • Fill the potable water tank with 150 l (39.63 USgal) of water.
At service panel 2023VU:
  • The blue '3/4' LED on quantity indicator 6MA comes on.

On the FAP, on the WATER/WASTE page:
  • '75%' is shown on the potable-water tank symbol.
8.At service panel 2023VU:
  • Fill the potable water tank with 200 l (52.83 USgal) of water.
At service panel 2023VU:
  • The blue 'F' LED on quantity indicator 6MA comes on.
  • Fill/overflow drain valve 8MA closes.
  • The TANK FULL control light comes on.
  • The overflow-valve control light goes off.
  • The fill and drain handle goes back to the NORMAL position.

On the FAP, on the WATER/WASTE page:
  • '100%' is shown on the potable-water tank symbol.
9.At service panel 2023VU:
  • Push and hold door limit switch 5MA.
At service panel 2023VU:
  • The TANK FULL control light goes off.

At FAP 120RH:
  • The SERVICE DOOR OPEN message is not shown.
5. Close-up
Subtask 38-13-00-080-050-A
A. Disconnect the CART - SERVICING, WATER, POTABLE at service panel 2023VU.
Subtask 38-13-00-410-050-A
B. Close Access
   (1) Close potable-water service door 171AL.
   (2) Remove the access platform(s).
Subtask 38-13-00-862-050-A
C. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 06:17:50 UTC