Operational Test of the Quantity Indicating System
TASK 38-13-00-710-001-A
Operational Test of the Quantity Indicating System
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 38-13-00-861-050-A Subtask 38-13-00-860-050-A
Subtask 38-13-00-710-050-B ** ON A/C NOT FOR ALL
Subtask 38-13-00-080-050-A
[Rev.10 from 2021]
2026.04.01 06:17:50 UTC
Operational Test of the Quantity Indicating System
ZONE: 170
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | 1 | CART - SERVICING, WATER, POTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 170 | AFT CAB U/FLOOR COMPT AFT BHD OF BULK |
| 171AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 12-24-38-680-001-A | Draining of the Potable Water System (with Electrical Power) |
| TASK 12-24-38-680-002-A | Draining of the Potable Water System (without Electrical Power) |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 38-13-00-861-050-A Subtask 38-13-00-860-050-A
B. Preparation for Test
(1) Put an ACCESS PLATFORM 2M (6 FT) in position below potable-water service door 171AL.
(2) Open potable-water service door 171AL.
(3) Drain the potable water tank (Ref. AMM TASK 12-24-38-680-001) or (Ref. AMM TASK 12-24-38-680-002).
(4) Connect the CART - SERVICING, WATER, POTABLE to the fill connection at service panel 2023VU.
Subtask 38-13-00-865-052-A (1) Put an ACCESS PLATFORM 2M (6 FT) in position below potable-water service door 171AL.
(2) Open potable-water service door 171AL.
(3) Drain the potable water tank (Ref. AMM TASK 12-24-38-680-001) or (Ref. AMM TASK 12-24-38-680-002).
(4) Connect the CART - SERVICING, WATER, POTABLE to the fill connection at service panel 2023VU.
C. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WATER SYSTEM-QANT-IND | 1MA | B01 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-QUANT-IND | 1MA | B06 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER SYS-DRAIN | 1MP | B05 |
| ** ON A/C NOT FOR ALL | |||
| 2001VU | WATER-SYS-DRAIN | 1MP | B05 |
Subtask 38-13-00-710-050-B ** ON A/C NOT FOR ALL
A. Do this test.
Subtask 38-13-00-710-050-D ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.At service panel 2023VU:
| At service panel 2023VU:
|
| |
|
|
|
| | On Forward Attendant Panel (FAP) 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
2.At service panel 2023VU:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
3.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
4.At service panel 2023VU:
| At service panel 2023VU:
|
| | On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
5.At service panel 2023VU:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
6.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
7.At service panel 2023VU:
| At service panel 2023VU:
|
| | On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
8.At service panel 2023VU:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
9.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
10.At service panel 2023VU:
| At service panel 2023VU:
|
| | On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
11.At service panel 2023VU:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
12.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
A. Do this test.
Subtask 38-13-00-710-050-K ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.At service panel 2023VU:
| At the Flight Attendant Panel (FAP) 124RH:
|
2.On the FAP:
| On the FAP:
|
3.On the WATER/WASTE page:
| ON the WATER/WASTE page:
|
4.At service panel 2023VU:
| At service panel 2023VU:
|
5.On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
| On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
|
6.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, WATER/WASTE page:
|
7.On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
| On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
|
8.At service panel 2023VU:
| At service panel 2023VU:
|
9.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, WATER/WASTE page:
|
10.On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
| On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
|
11.At service panel 2023VU:
| At service panel 2023VU:
|
12.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, WATER/WASTE page:
|
13.On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
| On the (FAP, WATER/WASTE page) PRESELECTED QUANTITY box:
|
14.At service panel 2023VU:
| At service panel 2023VU:
|
15.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, WATER/WASTE page:
|
16.At service panel 2023VU:
| At service panel 2023VU:
|
| | At the Flight Attendant Panel (FAP) 124RH:
|
A. Do this test.
Subtask 38-13-00-710-050-P ** ON A/C NOT FOR ALL | ACTION | RESULT |
|---|---|
1.At service panel 2023VU:
| At service panel 2023VU:
|
| | At Forward Attendant Panel (FAP) 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
2.At service panel 2023VU:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
3.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
4.At service panel 2023VU:
| At service panel 2023VU:
|
| | On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
5.At service panel 2023VU:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
6.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
7.At service panel 2023VU:
| At service panel 2023VU:
|
| | On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
8.At service panel 2023VU:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
9.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
10.At service panel 2023VU:
| At service panel 2023VU:
|
| | On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
11.At service panel 2023VU:
| At service panel 2023VU:
|
| | On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
12.At FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
| On FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
|
A. Test(s)
(1) Do the test that follows:
Subtask 38-13-00-710-050-S ** ON A/C NOT FOR ALL (1) Do the test that follows:
| ACTION | RESULT |
|---|---|
1.At service panel 2023VU:
| At Flight Attendant Panel (FAP) 120RH:
|
2.On the FAP:
| On the FAP:
|
3.At service panel 2023VU:
| At service panel 2023VU:
|
4.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, on the WATER/WASTE page:
|
5.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, on the WATER/WASTE page:
|
6.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, on the WATER/WASTE page:
|
7.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, on the WATER/WASTE page:
|
8.At service panel 2023VU:
| At service panel 2023VU:
|
| | At FAP 120RH:
|
A. Test(s)
(1) Do the test that follows:
Subtask 38-13-00-710-050-T ** ON A/C NOT FOR ALL (1) Do the test that follows:
| ACTION | RESULT |
|---|---|
1.At service panel 2023VU:
| At Flight Attendant Panel (FAP) 120RH:
|
2.On the FAP:
| On the FAP:
|
3.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, on the WATER/WASTE page:
|
4.At service panel 2023VU:
| At service panel 2023VU:
|
5.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, on the WATER/WASTE page:
|
6.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, on the WATER/WASTE page:
|
7.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, on the WATER/WASTE page:
|
8.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, on the WATER/WASTE page:
|
9.At service panel 2023VU:
| At service panel 2023VU:
|
| | At FAP 120RH:
|
A. Test(s)
(1) Do the test that follows:
5. Close-up(1) Do the test that follows:
| ACTION | RESULT |
|---|---|
1.At service panel 2023VU:
| At Flight Attendant Panel (FAP) 120RH:
|
2.On the FAP:
| On the FAP:
|
3.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, on the WATER/WASTE page:
|
4.At service panel 2023VU:
| At service panel 2023VU:
|
5.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, on the WATER/WASTE page:
|
6.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, on the WATER/WASTE page:
|
7.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, on the WATER/WASTE page:
|
8.At service panel 2023VU:
| At service panel 2023VU:
|
| | On the FAP, on the WATER/WASTE page:
|
9.At service panel 2023VU:
| At service panel 2023VU:
|
| | At FAP 120RH:
|
Subtask 38-13-00-080-050-A
A. Disconnect the CART - SERVICING, WATER, POTABLE at service panel 2023VU.
Subtask 38-13-00-410-050-A Subtask 38-13-00-862-050-A