Removal of the High Pressure Tee Duct
TASK 36-11-49-000-002-A
Removal of the High Pressure Tee Duct
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 36-11-49-861-071-A ** ON A/C NOT FOR ALL
Subtask 36-11-49-020-079-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 12:38:49 UTC
Removal of the High Pressure Tee Duct
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
CAUTION:
USE A SECOND WRENCH TO APPLY COUNTER TORQUE TO THE UNION ON THE VALVE WHEN YOU CONNECT THE HP SENSE TUBE.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 49-00-00-860-009-A | APU Shutdown by External Power (131-9(A)) |
| TASK 49-00-00-860-009-A-01 | APU Shutdown by Batteries (131-9(A)) |
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 78-30-00-481-041-A | Make the Thrust Reverser Unserviceable for Maintenance |
| TASK 78-36-00-010-040-A | Opening of the Thrust Reverser Doors |
Subtask 36-11-49-861-071-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
Subtask 36-11-49-941-083-A ** ON A/C NOT FOR ALL (Ref. AMM TASK 24-41-00-861-002) or (Ref. AMM TASK 24-41-00-861-002).
B. Safety Precautions
(1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the AIR COND panel 30VU:
Subtask 36-11-49-865-109-A ** ON A/C NOT FOR ALL (1) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(2) On the AIR COND panel 30VU:
- make sure that the ENG 1(2) BLEED pushbutton switch is released (the OFF legend is on),
- make sure that the APU BLEED pushbutton switch is released (the ON legend is off),
- put a WARNING NOTICE(S) to tell persons not to operate the pneumatic system.
- put a WARNING NOTICE(S) to tell persons not to start the engine 1(2).
- Put a WARNING NOTICE(S) to tell persons not to pressurize the pneumatic system.
- make sure that the ON legend of the ENG/FADEC GND PWR 1(2) pushbutton switch is off,
- put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 36-11-49-010-102-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | AIR BLEED/ENG 1/CTL | 3HA1 | D12 |
| 49VU | AIR BLEED/ENG 1/MONG | 2HA1 | D11 |
| 122VU | AIR BLEED/ENG 2/CTL | 3HA2 | Z23 |
| 122VU | AIR BLEED/ENG 2/MONG | 2HA2 | Z22 |
D. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position.
Subtask 36-11-49-040-082-A ** ON A/C NOT FOR ALL Subtask 36-11-49-010-103-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position.
F. Open the thrust reverser doors (Ref. AMM TASK 78-36-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
4. Procedure(1) FOR [1000EM1] (ENGINE-1)
451AL 452AR
(2) FOR [1000EM2] (ENGINE-2)
461AL 462AR
Subtask 36-11-49-020-079-A ** ON A/C NOT FOR ALL
A. Removal of the High Pressure (HP) Tee Duct
(1) If you use the APU to energize the electrical circuits, stop the APU:
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
(4) Remove the coupling (10) and the seal (5) that connect the HP tee duct (15) to the lower HP duct.
(5) Remove the coupling (30) and the seal (25) that connect the HP tee duct (15) to the HP regulator valve (20).
(6) Remove the HP tee duct (15) from the engine.
(7) Put PLUG - BLANKING on the open ends of the HP tee duct (15).
(8) Put PLUG - BLANKING on the upper HP duct, the lower HP duct, and the HP regulator valve (20).
(1) If you use the APU to energize the electrical circuits, stop the APU:
- For GTCP 36-300 APU (Ref. AMM D/O 49-00-00-86)
- For APS 3200 APU (Ref. AMM D/O 49-00-00-86)
- For 131-9(A) APU (Ref. AMM TASK 49-00-00-860-009).
(a) Make sure that the pressure and the temperature of the bleed-air duct system are in ambient conditions.
WARNING:
MAKE SURE THAT THE PNEUMATIC SYSTEM IS DEPRESSURIZED BEFORE YOU START WORK. PRESSURIZED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING:
DO NOT TOUCH THE UNIT UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
(3) Remove the coupling (10) and the seal (5) that connect the HP tee duct (15) to the upper HP duct. (4) Remove the coupling (10) and the seal (5) that connect the HP tee duct (15) to the lower HP duct.
(5) Remove the coupling (30) and the seal (25) that connect the HP tee duct (15) to the HP regulator valve (20).
(6) Remove the HP tee duct (15) from the engine.
(7) Put PLUG - BLANKING on the open ends of the HP tee duct (15).
(8) Put PLUG - BLANKING on the upper HP duct, the lower HP duct, and the HP regulator valve (20).
High Pressure (HP) Tee DUCT