W DOC AIRBUS | AMM A320F

Read CFDIU for IR CURRENT STATUS


TASK 34-14-00-740-002-A
Read CFDIU for IR CURRENT STATUS


ZONE: 210
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 1M(3 FT)
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-010-A
Procedure to Get Access to the SYSTEM REPORT/TEST NAV Page
TASK 34-10-00-860-002-A
ADIRS Start Procedure
TASK 34-10-00-860-005-A
ADIRS Stop Procedure
3. Job Set-up
Subtask 34-14-00-010-053-B ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put the ACCESS PLATFORM 1M(3 FT) in position at access door 822.
   (2) Open access door 822.
   (3) On battery power center 105VU:
  • loosen the two screws and remove the protective cover.
Subtask 34-14-00-860-053-B ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
   (2) Do the ADIRS start procedure (Ref. AMM TASK 34-10-00-860-002).
Subtask 34-14-00-875-050-A ** ON A/C NOT FOR ALL
C. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAUTO FLT/FCU/19CA1B05
49VUL/G/LGCIU/SYS1/NORM1GAC09
49VUNAV PROBES/ADIRU3/PWR/SWTG8FPF09
49VUNAV PROBES/ADIRU 1/AND AOA 1/26VAC5FP1F07
49VUNAV PROBES/ADIRU1/115VAC4FP1F06
105VUADIRS/ADIRU1/28VDC6FP1C02
121VUAUTO FLT/FCU/29CA2M21
121VUADIRS/ADIRU/2PWR/SHED10FPN10
121VUADIRS/ADIRU/3PWR/SWTG9FPN09
121VUADIRS/ADIRU/2/26VAC AND AOA5FP2N08
121VUADIRS/ADIRU/3/26VAC AND AOA5FP3N07
121VUADIRS/ADIRU/2/115VAC4FP2N06
121VUADIRS/ADIRU/3/115VAC4FP3N05
121VUADIRS/ADIRU/2/28VDC6FP2N04
121VUADIRS/ADIRU/3/28VDC6FP3N03
121VUHYDRAULIC/LGCIU/SYS22GAQ35
121VUHYDRAULIC/LGCIU/SYS1/GRND SPLY52GAQ34
Subtask 34-14-00-875-051-A ** ON A/C NOT FOR ALL
D. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAUTO FLT/FAC1/28VDC5CC1B04
121VUAUTO FLT/FAC2/28VDC5CC2M19
4. Procedure
Subtask 34-14-00-740-064-E ** ON A/C NOT FOR ALL
A. Read CFDIU for IR CURRENT STATUS
ACTION
RESULT
On the center pedestal, on one MCDU:
On the center pedestal, on the MCDU:
1.Get access to the SYSTEM REPORT/TEST/NAV page.
(Ref. AMM TASK 31-32-00-860-010).
  • The SYSTEM REPORT/TEST/NAV page comes into view.
2.On the NAV page:

  • Push the line key adjacent to the IR1 (IR2) (IR3) indication.
  • The IR1 (IR2) (IR3) page comes into view.
3.On the IR1 (IR2) (IR3) page:

  • Push the line key adjacent to the SPECIFIC DATA indication.
  • The IR1 (IR2) (IR3) SPECIFIC DATA page comes into view.
4.On the IR1 (IR2) (IR3) SPECIFIC DATA page:

  • Push the line key adjacent to the CURRENT STATUS indication.
  • The IR1 (IR2) (IR3) CURRENT STATUS 1/8 page comes into view.
5. Close-up
Subtask 34-14-00-860-054-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) On the center pedestal, on the MCDU, push the line key adjacent to the RETURN indication until the MCDU MENU page comes into view.
   (2) Do the ADIRS stop procedure (Ref. AMM TASK 34-10-00-860-005).
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
Subtask 34-14-00-875-052-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAUTO FLT/FAC1/28VDC5CC1B04
121VUAUTO FLT/FAC2/28VDC5CC2M19
Subtask 34-14-00-410-053-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Install the protective cover on battery power center 105VU.
   (2) Tighten the two screws.
   (3) Close access door 822.
   (4) Remove the access platform.
[Rev.10 from 2021] 2026.04.01 04:13:29 UTC