Deactivation of the Lower ECAM DU when AC ESS FEED control is operative
TASK 31-68-00-040-006-A
Deactivation of the Lower ECAM DU when AC ESS FEED control is operative
MMEL 31-63-05A
SDU
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 31-68-00-860-073-A
Subtask 31-68-00-710-057-A
Subtask 31-68-00-860-075-A
[Rev.10 from 2021]
2026.04.01 00:39:06 UTC
Deactivation of the Lower ECAM DU when AC ESS FEED control is operative
ZONE: 210
1. Reason for the JobMMEL 31-63-05A
SDU
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 210 | CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-25-00-710-001-A | Operational Check of AC ESS Generation Switching |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 31-68-00-860-073-A
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
4. Procedure(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 31-68-00-710-057-A
A. Do the operational test of the AC essential generation switching (Ref. AMM TASK 24-25-00-710-001).
5. Close-upSubtask 31-68-00-860-075-A
A. Aircraft Maintenance Configuration
(1) Put a temporary placard in the cockpit to tell persons that the lower ECAM DU is deactivated.
(2) Make an entry in the log book.
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) Put a temporary placard in the cockpit to tell persons that the lower ECAM DU is deactivated.
(2) Make an entry in the log book.
(3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).