Operational Test of the System Data Acquisition Concentrator (SDAC)


TASK 31-50-00-710-003-A
Operational Test of the System Data Acquisition Concentrator (SDAC)


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
ZONE: 210
1. Reason for the Job
Make sure that the amber visual and audio cautions are operated by a SDAC.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-60-00-860-001-A
EIS Start Procedure
3. Job Set-up
Subtask 31-50-00-860-054-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001)
Subtask 31-50-00-865-055-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUSDAC/1/SPLY3WVF04
49VUSDAC/2/26VAC SYNC/AC ESS BUS6WVF03
49VUSDAC/1/26VAC SYNC/AC ESS BUS5WVF02
121VUEIS/SDAC1 AND 2/BUS2/28VDC44WVP03
121VUEIS/SDAC/2/SPLY2WVQ06
121VUEIS/SDAC/1/BUS2/26VAC SYNC AC7WVQ03
121VUEIS/SDAC/2/BUS2/26VAC SYNC AC8WVQ02
4. Procedure
Subtask 31-50-00-710-053-A
A. Test
ACTION
RESULT
1.On the panel 121VU :

  • open the circuit breaker 2WV .
  • on the upper ECAM DU:
    * the FWS SDAC2 FAULT indication comes into view.
  • open the circuit breaker 44WV.
* the ELEC DC BUS2 FAULT indication comes into view.
  • on the lower ECAM display unit:
    * the ELEC page comes into view.
  • you hear the single chime.
  • on the glareshield :
    * the CAPT and F/O MASTER CAUT lights come on.
2.On the glareshield :

  • push then release the CAPT or F/O MASTER CAUT pushbutton switch.
  • the CAPT and F/O MASTER CAUT lights go off.
3.On the panel 121VU :

  • close the circuit breaker 44WV.
  • on the upper ECAM display unit:
    * the warning message goes out of view.
  • on the lower ECAM display unit:
    * the ELEC page goes out of view and the DOOR/OXY page comes into view.
  • close the circuit breaker 2WV.
  • On the upper ECAM DU:
    * FWS SDAC2 FAULT goes out of view.
  • after a few seconds, other cautions can come into view.
4.On the ECAM control panel:

  • push the CLR key to reset all warnings.
  • on the upper ECAM DU:
    * the MEMO indication comes into view.
  • on the lower ECAM DU:
    * the DOOR page comes into view.
5.On the panel 49VU :

  • open the circuit breaker 3WV .
  • on the upper ECAM DU:
    * FWS SDAC1 FAULT comes into view.
6.On the panel 121VU :

  • open the circuit breaker 44WV.
  • make sure that the cautions given in paragraph 1 come into view.
  • close the circuit breaker 44WV.
  • the cautions given before go out of view.
7.On the panel 49VU :

  • close the circuit breaker 3WV .
  • On the upper ECAM DU:
    * FWS SDAC1 FAULT goes out of view.
5. Close-up
Subtask 31-50-00-860-055-A
A. Put the aircraft back to its initial configuration.
   (1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
   (2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002)
   (3) Make sure that the work area is clean and clear of tools and other items.