W DOC AIRBUS | AMM A320F

Operational Test of the Flight Warning Computer (FWC)


TASK 31-50-00-710-002-A
Operational Test of the Flight Warning Computer (FWC)


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
ZONE: 210
1. Reason for the Job
To make sure that the red visual and audio warnings are operated by a FWC.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-60-00-860-001-A
EIS Start Procedure
3. Job Set-up
Subtask 31-50-00-860-052-A
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001)
Subtask 31-50-00-865-054-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUENGINE/2/FIRE DET/LOOP B8WD2A07
49VUENGINE/1/FIRE DET/LOOP A7WD1A06
49VUFWS/FWC1/SPLY3WWF01
** ON A/C NOT FOR ALL
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B2WE1Q44
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B2WE2Q42
** ON A/C NOT FOR ALL
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A1WE1Q43
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A1WE2Q41
** ON A/C ALL
121VUENGINE/ENG2/FIRE DET/LOOP A7WD2Q39
121VUENGINE/ENG1/FIRE DET/LOOP B8WD1Q38
121VUEIS/FWC2/SPLY2WWQ07
** ON A/C NOT FOR ALL
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B2WE1Q44
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B2WE2Q42
** ON A/C NOT FOR ALL
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B2WE1Q43
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A1WE1Q42
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B2WE2Q41
121VUENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A1WE2Q40
4. Procedure
Subtask 31-50-00-710-052-B
A. Test
NOTE: Ignore all the indications that are not related to the ECAM system.
ACTION
RESULT
1.On the REAR C/B 121VU:

  • open the circuit breaker 2WW.
  • on the upper ECAM DU:
    FWS FWC 2 FAULT indication comes into view.
2.On the overhead panel 20VU, on the ENG/APU FIRE panel 1WD:

  • push the ENG1 loop/squib TEST pushbutton switch.
  • you hear the repetitive chime.
  • on the glareshield:
    *half the MASTER WARN lights flash; MASTER for CAPT side, WARN for F/O side.
  • on the upper ECAM DU:
    *the red ENG1 FIRE indication comes into view.
  • on the lower ECAM DU:
    *the ENGINE page comes into view.
3.Release the ENG1 loop/squib TEST pushbutton switch.
  • the warnings go out of view except FWS FWC2 FAULT.
  • on the lower ECAM DU:
    *the DOOR/OXY page comes into view.
4.Close the circuit breaker 2WW.
  • On the upper ECAM DU:
    *FWS FWC2 FAULT goes out of view.
  • after not many seconds, the MASTER lights can come on and some warnings can come into view.
    *if not, do not do the step 5.
5.On the ECAM control panel:

  • push the CLR key to reset all warnings.
  • on the upper ECAM DU:
    *the MEMO indication comes into view.
  • on the lower ECAM DU:
    *the DOOR page comes into view.
6.On the OVERHEAD C/B panel 49VU:

  • open the circuit breaker 3WW.
  • on the upper ECAM DU:
    FWS FWC 1 FAULT indication comes into view:
7.On the ENG/APU FIRE panel 1WD:

  • push the ENG1 loop/squib TEST pushbutton switch.
  • you hear the repetitive chime.
  • on the glareshield:
    *half the MASTER WARN lights flash; WARN for CAPT side, MASTER for F/O side.
  • on the upper ECAM DU:
    *the red ENG1 FIRE indication comes into view.
  • on the lower ECAM DU:
    *the ENGINE page comes into view.
8.Release the ENG1 loop/squib TEST pushbutton switch.
  • the warnings go out of view, except FWS FWC1 FAULT
  • on the lower ECAM DU:
    *the DOOR/OXY page comes into view.
9.Close the circuit breaker 3WW.
  • on the upper ECAM DU:
    FWS FWC1 FAULT goes out of view.
10.Push the MASTER light if it is on.

5. Close-up
Subtask 31-50-00-860-053-A
A. Put the aircraft back to its initial configuration.
   (1) On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.
   (2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002)
   (3) Make sure that the work area is clean and clear of tools and other items.