W DOC AIRBUS | AMM A320F

Pressurize the Yellow Hydraulic System with the Electric Pump


TASK 29-24-00-863-001-A
Pressurize the Yellow Hydraulic System with the Electric Pump


WARNING: MAKE SURE THAT THE CONTROLS AGREE WITH THE POSITION OF THE ITEMS THEY OPERATE BEFORE YOU PRESSURIZE A HYDRAULIC SYSTEM. UNWANTED MOVEMENT OF HYDRAULICALLY OPERATED ITEMS CAN CAUSE SERIOUS INJURY AND/OR DAMAGE.
WARNING: PRESSURIZE ONLY THE HYDRAULIC SYSTEM(S) THAT IS (ARE) NECESSARY FOR THE TASK. ISOLATE THE OTHER HYDRAULIC SYSTEM(S) BEFORE YOU SUPPLY HYDRAULIC POWER TO THE AIRCRAFT.
NOTE: The simulation of in-flight conditions while Green and Yellow hydraulic systems are off can cause an inhibition of PTU.
FIN: 3075GX
1. Reason for the Job
To pressurize the Yellow hydraulic system with the Yellow electric pump, for maintenance procedures.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 12-12-29-611-001-A
Fill the Hydraulic Fluid Reservoir with a Hand Pump
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 29-14-00-614-002-A
Pressurization of the Hydraulic Reservoirs through the Ground Connector
TASK 29-14-00-614-002-A-01
Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU)
TASK 29-23-00-860-001-A
Disconnection of the Isolation Coupling of the Power Transfer Unit (PTU)
TASK 31-60-00-860-001-A
EIS Start Procedure
3. Job Set-up
Subtask 29-24-00-860-052-A
A. Aircraft Maintenance Configuration
   (1) Energize the electrical circuits (Ref. AMM TASK 24-41-00-861-002).
Subtask 29-24-00-865-057-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUPTU INHIT/Y SYS1808GLQ33
121VUPTU INHIT/G SYS1807GLQ32
** ON A/C NOT FOR ALL
121VUHYDRAULIC / PTU FLT INHIB1825GLQ31
** ON A/C NOT FOR ALL
121VUHYDRAULIC-PTU FLT INHIT1825GLQ32
Subtask 29-24-00-860-060-A
C. Aircraft Maintenance Configuration
   (1) Set the Electronic Centralized Aircraft Monitor (ECAM) to on (Ref. AMM TASK 31-60-00-860-001).
   (2) On the ECAM control panel on the center pedestal, push the HYD pushbutton switch (P/BSW). Make sure that the ECAM lower Display Unit (DU) shows the HYD page.
   (3) Make sure that the ECAM does not show any of these conditions:
  • Low air pressure in the Yellow reservoir,
  • Low fluid level in the reservoirs.
   (4) In addition, if you will operate the PTU, make sure that these conditions are also not shown on the ECAM:
  • Low air pressure in the Green reservoir,
  • Low fluid level in the Green reservoir.
   (5) If necessary, pressurize the reservoir(s) (Ref. AMM TASK 29-14-00-614-002).
   (6) If necessary, add fluid to the reservoir(s) (Ref. AMM TASK 12-12-29-611-001).
Subtask 29-24-00-865-050-A
D. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
** ON A/C ALL
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
4. Procedure
Subtask 29-24-00-863-050-A
A. Pressurization with the Electric Pump
   (1) If it is necessary to use the Yellow hydraulic system only, continue as follows:
NOTE: Usually the PTU automatically pressurizes the Green hydraulic system together with the Yellow hydraulic system. If you pressurize the Yellow system only,then it is necessary to stop the operation of the PTU.
     (a) Disconnect the isolation coupling of the Power Transfer Unit (PTU) (Ref. AMM TASK 29-23-00-860-001)
NOTE: Disconnection of the isolation coupling is only necessary if the system on the opposite side is disconnected for maintenance.
     (b) Press and release the PTU/AUTO pushbutton switch 1802GL on the overhead panel 40VU.
     (c) Make sure that the OFF legend comes on.
   (2) On the overhead panel 40VU, push and release the YELLOW ELEC PUMP pushbutton switch 3804GX.
   (3) Make sure that the ON legend comes on.
   (4) Make sure that the Yellow electric pump starts.
   (5) On the lower DU of the ECAM, make sure that the YELLOW hydraulic system has a pressure of approximately 3000 psi.
NOTE: If the ECAM system is not available, you can check the pressure of 3000 +/-100 psi on the Yellow power accumulator (3070GM).
NOTE: To prevent a possible overheating of the hydraulic fluid, operate the electric pump only as long as it is necessary to do your maintenance procedure.
5. Close-up
Subtask 29-24-00-865-058-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUPTU INHIT/Y SYS1808GLQ33
121VUPTU INHIT/G SYS1807GLQ32
** ON A/C NOT FOR ALL
121VUHYDRAULIC / PTU FLT INHIB1825GLQ31
** ON A/C NOT FOR ALL
121VUHYDRAULIC-PTU FLT INHIT1825GLQ32
[Rev.10 from 2021] 2026.04.01 04:00:49 UTC