W DOC AIRBUS | AMM A320F

Installation of the RAT Delta Pressure Indicator


TASK 29-22-51-400-012-A
Installation of the RAT Delta Pressure Indicator


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING: MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
HOT AIR BLOWER OPERATING 40 DEG C(104 F)
No specific
2
WARNING NOTICE(S)
No specific
Torque wrench: range to between 11.2 and 9.1 m.N (99.12 and 80.53 lbf.in ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.02ABA1)
Phosphate Ester Hydraulic Fluid-General Power - -
(Material No.08BBH1)
Non Aqueous Cleaner-- Acetone -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
4
PACKING
AIPC 29-22-51-01-250
5
PACKING
AIPC 29-22-51-01-260
2
DUST COVER
AIPC 29-22-51-01-410
1
SHRINK TUBE
AIPC 29-22-51-01-420
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 29-00-00-910-002-A
Safety Procedures of the Hydraulic System
TASK 29-10-00-863-003-A
Pressurize the Blue Hydraulic System with a Hydraulic Ground Power-Cart
TASK 29-10-00-863-003-A-01
Pressurize the Blue Hydraulic System with the Blue Electric Pump
TASK 29-10-00-864-003-A
Depressurize the Blue Hydraulic System
TASK 29-14-00-614-001-A
Depressurization of the Hydraulic Reservoirs
TASK 29-14-00-614-002-A
Pressurization of the Hydraulic Reservoirs through the Ground Connector
TASK 29-14-00-614-002-A-01
Pressurization of the Hydraulic Reservoirs with the Auxiliary Power Unit (APU)
TASK 29-22-00-710-007-A
Operational Test of the Manual Deployment and the Retraction of the Ram Air Turbine
TASK 29-22-00-869-005-A
Extension of the Ram Air Turbine (RAT) on the Ground
TASK 29-22-00-869-006-A
Retraction of the Ram Air Turbine (RAT) on the Ground
3. Job Set-up
Subtask 29-22-51-860-104-A
A. Aircraft Maintenance Configuration
WARNING: OBEY THE HYDRAULIC SAFETY PROCEDURES.
   (1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002).
   (2) Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration (Ref. AMM TASK 29-00-00-864-001).
   (3) Make sure that the reservoir of the Blue hydraulic system is depressurized (Ref. AMM TASK 29-14-00-614-001).
   (4) Make sure that the WARNING NOTICE(S) are in position to tell persons not to pressurize the Blue hydraulic system:
  • in the cockpit on the hydraulic section 40VU of the overhead panel,
  • on the ground service panel of the Blue hydraulic system.
   (5) Make sure that the safety barriers are in position.
   (6) Make sure that the RAT is extended (Ref. AMM TASK 29-22-00-869-005).
Subtask 29-22-51-865-101-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUHYD/RAT/CTL2801GED14
** ON A/C NOT FOR ALL
49VUHYD/RAT/CTL2801GEB13
** ON A/C ALL
106VUCSM/G /EV/MAN/SPLY6XEB04
121VUHYDRAULIC/RAT/SPLY/EXTN/SOL12803GEP33
4. Procedure
Subtask 29-22-51-420-067-A Subtask 29-22-51-865-102-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUHYD/RAT/CTL2801GED14
** ON A/C NOT FOR ALL
49VUHYD/RAT/CTL2801GEB13
** ON A/C ALL
106VUCSM/G /EV/MAN/SPLY6XEB04
121VUHYDRAULIC/RAT/SPLY/EXTN/SOL12803GEP33
Subtask 29-22-51-860-105-A
C. Aircraft Maintenance Configuration
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Pressurize the reservoir of the Blue hydraulic system (
Ref. AMM TASK 29-14-00-614-002).
   (3) Pressurize the Blue hydraulic system (Ref. AMM TASK 29-10-00-863-003).
   (4) Examine the connection of the delta pressure indicator (1) and the RAT hydraulic pump housing (4) and make sure that there is no leak.
WARNING: MAKE SURE THAT THE RAT TRAVEL RANGE IS CLEAR BEFORE YOU EXTEND/RETRACT THE RAT.
   (5) Retract the RAT (Ref. AMM TASK 29-22-00-869-006).
   (6) Depressurize the Blue hydraulic system (Ref. AMM TASK 29-10-00-864-003).
Subtask 29-22-51-710-058-A
D. Test
   (1) Do the operational test of the manual deployment and the retraction of the RAT (Ref. AMM TASK 29-22-00-710-007).
   (2) Make sure that the delta pressure indicator (1) stays in the retracted position.
5. Close-up
Subtask 29-22-51-860-106-A
A. Put the aircraft back to the serviceable condition.
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the safety barriers.
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 00:26:18 UTC