Check of the Flap Rotary Actuator for Serviceable Condition (After Leakage)
TASK 27-54-00-612-001-A
Check of the Flap Rotary Actuator for Serviceable Condition (After Leakage)
Do this task only on actuators that show a leakage.
The purpose of the task is to measure the remaining volume of semi-fluid in a rotary actuator (after leakage).
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 27-54-00-941-068-A ** ON A/C NOT FOR ALL
Subtask 27-54-00-410-062-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 07:00:33 UTC
Check of the Flap Rotary Actuator for Serviceable Condition (After Leakage)
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
FIN: 6205CM ** ON A/C NOT FOR ALL
FIN: 6211CM ** ON A/C NOT FOR ALL
FIN: 6221CM ** ON A/C NOT FOR ALL
FIN: 6233CM ** ON A/C NOT FOR ALL
FIN: 6255CM ** ON A/C NOT FOR ALL
FIN: 6261CM ** ON A/C NOT FOR ALL
FIN: 6271CM ** ON A/C NOT FOR ALL
FIN: 6283CM ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 6211CM ** ON A/C NOT FOR ALL
FIN: 6221CM ** ON A/C NOT FOR ALL
FIN: 6233CM ** ON A/C NOT FOR ALL
FIN: 6255CM ** ON A/C NOT FOR ALL
FIN: 6261CM ** ON A/C NOT FOR ALL
FIN: 6271CM ** ON A/C NOT FOR ALL
FIN: 6283CM ** ON A/C NOT FOR ALL
Do this task only on actuators that show a leakage.
The purpose of the task is to measure the remaining volume of semi-fluid in a rotary actuator (after leakage).
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | SAFETY BARRIER(S) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 0.44 and 0.36 m.daN (38.94 and 31.86 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 0.66 and 0.54 m.daN (58.41 and 47.79 lbf.in ) ![]() | |
| A685064 | 1 | MEASURING-EQUIPMENT, SEMIFUID |
| FOR [6205CM] (FLAP ACTUATOR 1) | ||
| FOR [6255CM] (FLAP ACTUATOR 1) | ||
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.03GDB1) | Synthetic Oil base Grease-Gearboxes or Rotary actuator Lithium Thickened Semi-fluid - |
| (Material No.06LCG9) | Non Hardening Jointing Putty-Medium Temp. Area - - |
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [6205CM] (FLAP ACTUATOR 1) | |
| FOR [6255CM] (FLAP ACTUATOR 1) | |
| 734, 744 | |
| FOR [6211CM] (FLAP ACTUATOR 2) | |
| 573AB | |
| FOR [6221CM] (FLAP ACTUATOR 3) | |
| 575BB | |
| FOR [6233CM] (FLAP ACTUATOR 4) | |
| 575FB | |
| FOR [6261CM] (FLAP ACTUATOR 2) | |
| 673AB | |
| FOR [6271CM] (FLAP ACTUATOR 3) | |
| 675BB | |
| FOR [6283CM] (FLAP ACTUATOR 4) | |
| 675FB | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 27-50-00-866-008-A | Extension of the Flaps on the Ground |
| TASK 27-50-00-866-008-A-01 | Extension of the Flaps/Slats on the Ground |
| TASK 27-50-00-866-009-A | Retraction of the Flaps on the Ground |
| TASK 27-50-00-866-009-A-01 | Retraction of the Flaps/Slats on the Ground |
| TASK 27-50-00-866-011-A | Manual Extension of the Flaps |
| TASK 27-50-00-866-012-A | Manual Retraction of the Flaps |
| TASK 27-54-49-000-001-A | Removal of the Flap Track 1 Actuator |
| TASK 27-54-49-000-002-A | Removal of the Flap Track 2 Actuator |
| TASK 27-54-49-000-003-A | Removal of the Flap Track 3 Actuator |
| TASK 27-54-49-000-004-A | Removal of the Flap Track 4 Actuator |
| TASK 27-54-49-400-001-A | Installation of the Flap Track 1 Actuator |
| TASK 27-54-49-400-002-A | Installation of the Flap Track 2 Actuator |
| TASK 27-54-49-400-003-A | Installation of the Flap Track 3 Actuator |
| TASK 27-54-49-400-004-A | Installation of the Flap Track 4 Actuator |
| TASK 27-60-00-866-002-A | Extension-Retraction of the Spoilers for Maintenance |
| FOR [6205CM] (FLAP ACTUATOR 1) | |
| FOR [6255CM] (FLAP ACTUATOR 1) | |
| TASK 32-12-00-010-001-A | Open the Main Gear Doors for Access |
| TASK 32-12-00-410-001-A | Close the Main Gear Doors after Access |
| FOR [6211CM] (FLAP ACTUATOR 2) | |
| TASK 57-51-37-000-002-A | Removal of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB) |
| TASK 57-51-37-400-002-A | Installation of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB) |
| FOR [6221CM] (FLAP ACTUATOR 3) | |
| TASK 57-51-37-000-004-A | Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB) |
| TASK 57-51-37-400-004-A | Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB) |
| FOR [6233CM] (FLAP ACTUATOR 4) | |
| TASK 57-51-37-000-004-A | Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB) |
| TASK 57-51-37-400-004-A | Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB) |
| FOR [6261CM] (FLAP ACTUATOR 2) | |
| TASK 57-51-37-000-002-A | Removal of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB) |
| TASK 57-51-37-400-002-A | Installation of the Access Panels 571AB(671AB), 573AB(673AB), 573BB(673BB), 573CB(673CB), 573EB(673EB) |
| FOR [6271CM] (FLAP ACTUATOR 3) | |
| TASK 57-51-37-000-004-A | Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB) |
| TASK 57-51-37-400-004-A | Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB) |
| FOR [6283CM] (FLAP ACTUATOR 4) | |
| TASK 57-51-37-000-004-A | Removal of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB) |
| TASK 57-51-37-400-004-A | Installation of the Access Panels 575AB(675AB), 575BB(675BB), 575CB(675CB), 575DB(675DB), 575EB(675EB), 575FB(675FB), 575GB(675GB), 575HB(675HB) |
Subtask 27-54-00-941-068-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Put the WARNING NOTICE(S) in position in the cockpit to tell persons not to operate the flight controls and the landing gear doors.
(2) Put the SAFETY BARRIER(S) in position.
Subtask 27-54-00-860-083-A ** ON A/C NOT FOR ALL (1) Put the WARNING NOTICE(S) in position in the cockpit to tell persons not to operate the flight controls and the landing gear doors.
(2) Put the SAFETY BARRIER(S) in position.
B. Aircraft Maintenance Configuration
(2) Extend the spoilers 1 thru 5 (Ref. AMM TASK 27-60-00-866-002).
Subtask 27-54-00-865-087-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
(1) Extend the flaps fully (Ref. AMM TASK 27-50-00-866-008). (2) Extend the spoilers 1 thru 5 (Ref. AMM TASK 27-60-00-866-002).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 27-54-00-010-069-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B02 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 | 8CV | Q21 |
D. Get Access
(1) FOR [6205CM] (FLAP ACTUATOR 1), [6255CM] (FLAP ACTUATOR 1)
(a) Open the applicable Main Landing Gear (MLG) door 734 744 (Ref. AMM TASK 32-12-00-010-001).
(b) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position in the applicable MLG bay.
(2) FOR [6211CM] (FLAP ACTUATOR 2), [6261CM] (FLAP ACTUATOR 2)
(a) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below the applicable zone 573 (673).
(b) FOR [6211CM] (FLAP ACTUATOR 2)
(a) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below the applicable zone 575 (675).
(b) FOR [6221CM] (FLAP ACTUATOR 3)
4. Procedure(1) FOR [6205CM] (FLAP ACTUATOR 1), [6255CM] (FLAP ACTUATOR 1)
(a) Open the applicable Main Landing Gear (MLG) door 734 744 (Ref. AMM TASK 32-12-00-010-001).
(b) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position in the applicable MLG bay.
(2) FOR [6211CM] (FLAP ACTUATOR 2), [6261CM] (FLAP ACTUATOR 2)
(a) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below the applicable zone 573 (673).
(b) FOR [6211CM] (FLAP ACTUATOR 2)
- Remove the access panel 573AB (Ref. AMM TASK 57-51-37-000-002).
- Remove the access panel 673AB (Ref. AMM TASK 57-51-37-000-002).
(a) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE below the applicable zone 575 (675).
(b) FOR [6221CM] (FLAP ACTUATOR 3)
- Remove the access panel 575BB (Ref. AMM TASK 57-51-37-000-004).
- Remove the access panel 675BB (Ref. AMM TASK 57-51-37-000-004).
- Remove the access panel 575FB (Ref. AMM TASK 57-51-37-000-004).
- Remove the access panel 675FB (Ref. AMM TASK 57-51-37-000-004).
CAUTION:
DO NOT GET SEMI-FLUID LUBRICANT ON PLASTIC OR RUBBER MATERIALS. SEMI-FLUID LUBRICANT CAN CAUSE DAMAGE TO THE SURFACE. REMOVE UNWANTED SEMI-FLUID LUBRICANT WITH A LINT FREE CLOTH.
Subtask 27-54-00-612-050-A ** ON A/C NOT FOR ALL A. Filling procedure for the Flap Actuators:
(a) Use a clean lint-free cloth Textile-Lint free Cotton - (Material No.14SBA1) and the Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean:
(c) Remove the drain plug (2) from the flap actuator.
1 Connect one end of the hose to the semi-fluid pump. Connect the other end of the hose to the tee piece.
2 Fill the semi-fluid pump with the Synthetic Oil base Grease-Gearboxes or Rotary actuator Lithium Thickened Semi-fluid - (Material No.03GDB1) . Bleed the semi-fluid pump before you operate it.
3 When you have bled the semi-fluid pump, record the volume of the remaining semi-fluid in the semi-fluid pump.
4 Install the tee piece and the adaptor into the hole of the drain plug (2) of the flap actuator. Tighten the adaptor with your hand.
(e) Operate the semi-fluid pump as follows:
1 Loosen the lock screw of one plunger on the semi-fluid pump.
2 Operate the plunger to fill the flap actuator with the Synthetic Oil base Grease-Gearboxes or Rotary actuator Lithium Thickened Semi-fluid - (Material No.03GDB1) .
3 If one plunger chamber is empty, tighten the plunger lock screw and continue with the remaining plunger. Do this until the semi-fluid comes out of the vent plug hole of the actuator.
4 Calculate and record the volume of semi-fluid necessary to fill the flap actuator.
(f) Remove the semi-fluid pump, the hose, the tee piece and the adaptor from the flap actuator.
(g) Install (but do not tighten) the vent plug (1) in the flap actuator.
(h) Install (but do not tighten) the drain plug (2) in the flap actuator.
(2) Do the steps (1)(a) thru (1)(h) again for the:
(a) Remove the vent plug (1) from the flap actuator.
(b) Apply the jointing compound Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the mating surfaces of the vent plug (1) and the flap actuator.
(c) Install the vent plug (1) in the flap actuator and TORQUE the vent plug to between 0.66 and 0.54 m.daN (58.41 and 47.79 lbf.in )
.
(4) Torque the drain plug (2) of each flap actuator as follows:
(a) Remove the drain plug (2) from the flap actuator.
(b) Apply the jointing compound Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the mating surfaces of the drain plug (2) and the flap actuator.
(c) Install the drain plug (2) in the flap actuator and TORQUE the drain plug as follows:
Subtask 27-54-00-680-050-A ** ON A/C NOT FOR ALL - Flap actuator No.1 6205CM (6255CM)
- Flap actuator No.2 6211CM (6261CM)
- Flap actuator No.3 6221CM (6271CM)
- Flap actuator No.4 6233CM (6283CM)
(a) Use a clean lint-free cloth Textile-Lint free Cotton - (Material No.14SBA1) and the Non Aqueous Cleaner-General - - (Material No.08BAA9) to clean:
- The area around the vent plug (1)
- The area around the drain plug (2).
(c) Remove the drain plug (2) from the flap actuator.
NOTE: The drain plug (2) is at the bottom location of the flap actuator.
(d) Use the semi-fluid measuring equipment A685064 MEASURING-EQUIPMENT, SEMIFUID to fill the flap actuator as follows: 1 Connect one end of the hose to the semi-fluid pump. Connect the other end of the hose to the tee piece.
2 Fill the semi-fluid pump with the Synthetic Oil base Grease-Gearboxes or Rotary actuator Lithium Thickened Semi-fluid - (Material No.03GDB1) . Bleed the semi-fluid pump before you operate it.
3 When you have bled the semi-fluid pump, record the volume of the remaining semi-fluid in the semi-fluid pump.
4 Install the tee piece and the adaptor into the hole of the drain plug (2) of the flap actuator. Tighten the adaptor with your hand.
(e) Operate the semi-fluid pump as follows:
1 Loosen the lock screw of one plunger on the semi-fluid pump.
2 Operate the plunger to fill the flap actuator with the Synthetic Oil base Grease-Gearboxes or Rotary actuator Lithium Thickened Semi-fluid - (Material No.03GDB1) .
3 If one plunger chamber is empty, tighten the plunger lock screw and continue with the remaining plunger. Do this until the semi-fluid comes out of the vent plug hole of the actuator.
4 Calculate and record the volume of semi-fluid necessary to fill the flap actuator.
(f) Remove the semi-fluid pump, the hose, the tee piece and the adaptor from the flap actuator.
(g) Install (but do not tighten) the vent plug (1) in the flap actuator.
(h) Install (but do not tighten) the drain plug (2) in the flap actuator.
(2) Do the steps (1)(a) thru (1)(h) again for the:
- Flap actuator No.2 6211CM (6261CM)
- Flap actuator No.3 6221CM (6271CM)
- Flap actuator No.4 6233CM (6283CM).
(a) Remove the vent plug (1) from the flap actuator.
(b) Apply the jointing compound Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the mating surfaces of the vent plug (1) and the flap actuator.
(c) Install the vent plug (1) in the flap actuator and TORQUE the vent plug to between 0.66 and 0.54 m.daN (58.41 and 47.79 lbf.in )
. (4) Torque the drain plug (2) of each flap actuator as follows:
(a) Remove the drain plug (2) from the flap actuator.
(b) Apply the jointing compound Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the mating surfaces of the drain plug (2) and the flap actuator.
(c) Install the drain plug (2) in the flap actuator and TORQUE the drain plug as follows:
- Flap actuator No.1 and No.2 to between 0.66 and 0.54 m.daN (58.41 and 47.79 lbf.in )

- Flap actuator No.3 and No.4 to between 0.44 and 0.36 m.daN (38.94 and 31.86 lbf.in )
.
B. Removal Procedure for Unwanted Semi-fluid from the Flap Actuators (after Possible Overfill)
(2) Use the semi-fluid measurement equipment A685064 MEASURING-EQUIPMENT, SEMIFUID to remove the unwanted semi-fluid from the flap actuator No.1 6205CM (6255CM), as follows:
(a) Remove the vent plug (1) from the flap actuator.
(b) Remove the drain plug (2) from the flap actuator.
(d) Connect one end of the hose to the air pump. Connect the other end of the hose to the tee piece.
(e) Install the remaining tee piece, adaptor and hose into the hole of the drain plug (2) of the flap actuator. Tighten the adaptor with your hand.
(f) Operate the air pump 15 times to put air into the flap actuator. This will push out the unwanted semi-fluid through the drain plug hole. Make sure that you operate the air pump handle through its full range each time.
(g) Remove the air pump, hose, tee piece and the adaptor from the hole of vent plug (1).
(h) Remove the hose, tee piece and the adaptor from the hole of the drain plug (2).
(i) Install (but do not tighten) the vent plug (1) in the flap actuator.
(j) Install (but do not tighten) the drain plug (2) in the flap actuator.
(3) Do the steps (2)(a) thru (2)(j) again and remove the unwanted semi-fluid from the:
(a) Remove the vent plug (1) from the flap actuator.
(b) Apply the jointing compound Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the mating surfaces of the vent plug (1) and the flap actuator.
(c) Install the vent plug (1) in the flap actuator and TORQUE the vent plug to between 0.66 and 0.54 m.daN (58.41 and 47.79 lbf.in )
.
(5) Torque the drain plug (2) of each flap actuator as follows:
(a) Remove the drain plug (2) from the flap actuator.
(b) Apply the jointing compound Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the mating surfaces of the drain plug (2) and the flap actuator.
(c) Install the drain plug (2) in the flap actuator and TORQUE the drain plug as follows:
Subtask 27-54-00-200-051-A ** ON A/C NOT FOR ALL - Flap actuator No.1 6205CM (6255CM)
- Flap actuator No.2 6211CM (6261CM)
- Flap actuator No.3 6221CM (6271CM)
- Flap actuator No.4 6233CM (6283CM).
(2) Use the semi-fluid measurement equipment A685064 MEASURING-EQUIPMENT, SEMIFUID to remove the unwanted semi-fluid from the flap actuator No.1 6205CM (6255CM), as follows:
(a) Remove the vent plug (1) from the flap actuator.
(b) Remove the drain plug (2) from the flap actuator.
NOTE: The drain plug (2) is at the bottom location on the flap actuator.
(c) Install the tee piece and the adaptor into the hole of the vent plug (1) of the flap actuator. Tighten the adaptor with your hand. (d) Connect one end of the hose to the air pump. Connect the other end of the hose to the tee piece.
(e) Install the remaining tee piece, adaptor and hose into the hole of the drain plug (2) of the flap actuator. Tighten the adaptor with your hand.
(f) Operate the air pump 15 times to put air into the flap actuator. This will push out the unwanted semi-fluid through the drain plug hole. Make sure that you operate the air pump handle through its full range each time.
(g) Remove the air pump, hose, tee piece and the adaptor from the hole of vent plug (1).
(h) Remove the hose, tee piece and the adaptor from the hole of the drain plug (2).
(i) Install (but do not tighten) the vent plug (1) in the flap actuator.
(j) Install (but do not tighten) the drain plug (2) in the flap actuator.
(3) Do the steps (2)(a) thru (2)(j) again and remove the unwanted semi-fluid from the:
- Flap actuator No.2 6211CM (6261CM)
- Flap actuator No.3 6221CM (6271CM)
- Flap actuator No.4 6233CM (6283CM).
(a) Remove the vent plug (1) from the flap actuator.
(b) Apply the jointing compound Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the mating surfaces of the vent plug (1) and the flap actuator.
(c) Install the vent plug (1) in the flap actuator and TORQUE the vent plug to between 0.66 and 0.54 m.daN (58.41 and 47.79 lbf.in )
. (5) Torque the drain plug (2) of each flap actuator as follows:
(a) Remove the drain plug (2) from the flap actuator.
(b) Apply the jointing compound Non Hardening Jointing Putty-Medium Temp. Area - - (Material No.06LCG9) to the mating surfaces of the drain plug (2) and the flap actuator.
(c) Install the drain plug (2) in the flap actuator and TORQUE the drain plug as follows:
C. Permitted Volumes of Semi-Fluid
(1) Compare the quantity of semi-fluid added to the flap actuator(s) and recorded in step 4.A.(1)(e)4_, with the maximum values shown on the table that follows:
(a) If the volume of semi-fluid added to the actuator, is less than the values in the table:
5. Close-up(1) Compare the quantity of semi-fluid added to the flap actuator(s) and recorded in step 4.A.(1)(e)4_, with the maximum values shown on the table that follows:
| Actuator Type | Maximum Volume of Semi-Fluid permitted (CM3) |
|---|---|
| 791C | 320 |
| 792C/D | 460 |
| 793C | 660 |
| 794C | 490 |
| 1070C/D | 460 |
| 1071C/D | 460 |
| 1072C/D/E | 350 |
| 1073C/D | 660 |
| 1074C/D | 580 |
- The flap actuator is serviceable.
- for the Flap Track 1 Actuator 6205CM(6255CM) (Ref. AMM TASK 27-54-49-000-001) and (Ref. AMM TASK 27-54-49-400-001)
- for the Flap Track 2 Actuator 6211CM(6261CM) (Ref. AMM TASK 27-54-49-000-002) and (Ref. AMM TASK 27-54-49-400-002)
- for the Flap Track 3 Actuator 6221CM(6271CM) (Ref. AMM TASK 27-54-49-000-003) and (Ref. AMM TASK 27-54-49-400-003)
- for the Flap Track 4 Actuator 6233CM(6283CM) (Ref. AMM TASK 27-54-49-000-004) and (Ref. AMM TASK 27-54-49-400-004).
Subtask 27-54-00-410-062-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) FOR [6205CM] (FLAP ACTUATOR 1), [6255CM] (FLAP ACTUATOR 1)
(a) Close the applicable MLG door 734 744 (Ref. AMM TASK 32-12-00-410-001).
(3) Install the applicable access panel:
(a) FOR [6211CM] (FLAP ACTUATOR 2)
Install the access panel 573AB (Ref. AMM TASK 57-51-37-400-002)
(b) FOR [6261CM] (FLAP ACTUATOR 2)
Install the access panel 673AB (Ref. AMM TASK 57-51-37-400-002)
(c) FOR [6221CM] (FLAP ACTUATOR 3)
Install the access panel 575BB (Ref. AMM TASK 57-51-37-400-004)
(d) FOR [6271CM] (FLAP ACTUATOR 3)
Install the access panel 675BB (Ref. AMM TASK 57-51-37-400-004)
(e) FOR [6233CM] (FLAP ACTUATOR 4)
Install the access panel 575FB (Ref. AMM TASK 57-51-37-400-004)
(f) FOR [6283CM] (FLAP ACTUATOR 4)
Install the access panel 675FB (Ref. AMM TASK 57-51-37-400-004).
(4) Remove the access platform(s).
Subtask 27-54-00-865-088-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) FOR [6205CM] (FLAP ACTUATOR 1), [6255CM] (FLAP ACTUATOR 1)
(a) Close the applicable MLG door 734 744 (Ref. AMM TASK 32-12-00-410-001).
(3) Install the applicable access panel:
(a) FOR [6211CM] (FLAP ACTUATOR 2)
Install the access panel 573AB (Ref. AMM TASK 57-51-37-400-002)
(b) FOR [6261CM] (FLAP ACTUATOR 2)
Install the access panel 673AB (Ref. AMM TASK 57-51-37-400-002)
(c) FOR [6221CM] (FLAP ACTUATOR 3)
Install the access panel 575BB (Ref. AMM TASK 57-51-37-400-004)
(d) FOR [6271CM] (FLAP ACTUATOR 3)
Install the access panel 675BB (Ref. AMM TASK 57-51-37-400-004)
(e) FOR [6233CM] (FLAP ACTUATOR 4)
Install the access panel 575FB (Ref. AMM TASK 57-51-37-400-004)
(f) FOR [6283CM] (FLAP ACTUATOR 4)
Install the access panel 675FB (Ref. AMM TASK 57-51-37-400-004).
(4) Remove the access platform(s).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 27-54-00-860-084-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B07 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | FLIGHT CONTROLS/FLP/CTL AND MONG/SYS1 | 6CV | B02 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FLIGHT CONTROLS/FLP/CTL AND/MONG/SYS2 | 8CV | Q21 |
C. Put the aircraft back to its initial configuration.
(1) Retract the spoilers 1 thru 5 (Ref. AMM TASK 27-60-00-866-002).
(2) Retract the flaps fully (Ref. AMM TASK 27-50-00-866-009).
Subtask 27-54-00-942-074-A ** ON A/C NOT FOR ALL (1) Retract the spoilers 1 thru 5 (Ref. AMM TASK 27-60-00-866-002).
(2) Retract the flaps fully (Ref. AMM TASK 27-50-00-866-009).
D. Removal of Equipment
(1) Remove the safety barriers.
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Remove the safety barriers.
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Flap Actuator - Track 1