Installation of the Fan Fire Detectors
TASK 26-12-15-400-041-A
Installation of the Fan Fire Detectors
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 26-12-15-860-050-A ** ON A/C NOT FOR ALL
Subtask 26-12-15-420-052-A ** ON A/C NOT FOR ALL
Subtask 26-12-15-860-052-A ** ON A/C NOT FOR ALL Subtask 26-12-15-410-052-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 13:04:46 UTC
Installation of the Fan Fire Detectors
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | WARNING NOTICE(S) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.CP1040) | methyl ethyl ketone |
| (Material No.CP2244) | primer 1200 |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| No specific | primer SS4004 |
| No specific | sealant two part thixotropic silicone DC90-006 |
| No specific | sealant two parts thixotropic silicone RTV-88 |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 26-12-00-710-001-A | Operational Check of Loop/Squib |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 71-13-00-010-040-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-040-A | Closing of the Fan Cowl Doors |
Subtask 26-12-15-860-050-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) On the center pedestal, on the ENG panel 115VU:
(a) Make sure that the ENG/MODE/CRANK/NORM/IGN/START selector switch is in the NORM position.
(b) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
Subtask 26-12-15-010-055-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Make sure that the ENG/MODE/CRANK/NORM/IGN/START selector switch is in the NORM position.
(b) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) On the overhead maintenance panel 50VU, make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off. Make sure that a WARNING NOTICE(S) is in position to tell persons not to energize the FADEC 1(2).
(3) Make sure that the ground service network is energized (Ref. AMM TASK 24-42-00-861-001).
B. Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-040):
(1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
Subtask 26-12-15-865-057-A ** ON A/C NOT FOR ALL (1) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(2) FOR [1000EM2] (ENGINE-2)
447AL 448AR
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ENGINE/2/FIRE DET/LOOP B | 8WD2 | A07 |
| 49VU | ENGINE/1/FIRE DET/LOOP A | 7WD1 | A06 |
| 121VU | ENGINE/ENG2/FIRE DET/LOOP A | 7WD2 | Q39 |
| 121VU | ENGINE/ENG1/FIRE DET/LOOP B | 8WD1 | Q38 |
Subtask 26-12-15-420-052-A ** ON A/C NOT FOR ALL
A. Installation of the Fan Fire Detector
AFTER SB RA32026-6
(2) Install the grommets (20) on the fire-detector (5) support tube as follows:
(a) Wipe and clean surfaces.
1 Use a Textile-Lint free Cotton - (Material No.14SBA1) moist with methyl ethyl ketone (Material No.CP1040) to wipe the areas on the support tube where the grommets will be installed.
2 Use a Textile-Lint free Cotton - (Material No.14SBA1) moist with methyl ethyl ketone (Material No.CP1040) to clean the inner surfaces of the grommets (20).
(b) Apply primer.
1 Apply the primer 1200 (Material No.CP2244) or primer SS4004 to the inside surface of the grommets (20) and to the areas of the support tube where the grommets will be installed.
1 Mix the two parts of the sealant two part thixotropic silicone DC90-006 or sealant two parts thixotropic silicone RTV-88.
(d) Apply the sealant to the inside surface of the grommets (20) and to the areas of the support tube where the grommets will be located.
(e) Put the grommets (20) in position on the support tube.
(f) Install tie wraps (25) on the two ends of each grommet (20) to hold them in place.
END OF SB RA32026-6
(3) Remove the blanking caps from the connectors 4000WD1A, 4000WD2A and the fire detector.
(4) Connect the electrical connectors 4000WD1A and 4000WD2A to the fire detector (5). Tighten the connectors by hand and lock them by one-eighth turn.
Subtask 26-12-15-865-058-A ** ON A/C NOT FOR ALL CAUTION:
INSTALL THE FIRE DETECTORS AND THE RAIL AS ONE ASSEMBLY. THE FIRE DETECTOR SENSOR ELEMENTS CAN BE DAMAGED IF NOT SUPPORTED BY THE RAIL.
(1) Attach the fire detector (5) to the brackets installed on the accessory gearbox with clamps (10) and (15). AFTER SB RA32026-6
(2) Install the grommets (20) on the fire-detector (5) support tube as follows:
(a) Wipe and clean surfaces.
1 Use a Textile-Lint free Cotton - (Material No.14SBA1) moist with methyl ethyl ketone (Material No.CP1040) to wipe the areas on the support tube where the grommets will be installed.
2 Use a Textile-Lint free Cotton - (Material No.14SBA1) moist with methyl ethyl ketone (Material No.CP1040) to clean the inner surfaces of the grommets (20).
(b) Apply primer.
1 Apply the primer 1200 (Material No.CP2244) or primer SS4004 to the inside surface of the grommets (20) and to the areas of the support tube where the grommets will be installed.
NOTE: Let the primer dry for a minimum of 20 minutes at room temperature before the sealant is applied.
(c) Apply sealant. 1 Mix the two parts of the sealant two part thixotropic silicone DC90-006 or sealant two parts thixotropic silicone RTV-88.
(d) Apply the sealant to the inside surface of the grommets (20) and to the areas of the support tube where the grommets will be located.
(e) Put the grommets (20) in position on the support tube.
(f) Install tie wraps (25) on the two ends of each grommet (20) to hold them in place.
END OF SB RA32026-6
(3) Remove the blanking caps from the connectors 4000WD1A, 4000WD2A and the fire detector.
(4) Connect the electrical connectors 4000WD1A and 4000WD2A to the fire detector (5). Tighten the connectors by hand and lock them by one-eighth turn.
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 26-12-15-860-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | ENGINE/2/FIRE DET/LOOP B | 8WD2 | A07 |
| 49VU | ENGINE/1/FIRE DET/LOOP A | 7WD1 | A06 |
| 121VU | ENGINE/ENG2/FIRE DET/LOOP A | 7WD2 | Q39 |
| 121VU | ENGINE/ENG1/FIRE DET/LOOP B | 8WD1 | Q38 |
C. Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
Subtask 26-12-15-710-052-A ** ON A/C NOT FOR ALL (Ref. AMM TASK 31-60-00-860-001).
D. Do this test.
(1) On the ECAM DU, make sure that the FIRE ENG1(2) LOOP A (B) FAULT message has gone out of view .
(2) Do an operational test of the engine fire detection system (Ref. AMM TASK 26-12-00-710-001).
5. Close-up(1) On the ECAM DU, make sure that the FIRE ENG1(2) LOOP A (B) FAULT message has gone out of view .
(2) Do an operational test of the engine fire detection system (Ref. AMM TASK 26-12-00-710-001).
Subtask 26-12-15-860-052-A ** ON A/C NOT FOR ALL Subtask 26-12-15-410-052-A ** ON A/C NOT FOR ALL
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the WARNING NOTICE(S).
Subtask 26-12-15-862-052-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(3) Remove the WARNING NOTICE(S).
Fan Fire Detectors (4000WD1, 4000WD2)