1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 25-45-14-000-802-A
Removal of the Soap Dispenser of the Space Flex Lavatory
TASK 25-45-14-400-802-A
Installation of the Soap Dispenser of the Space Flex Lavatory
TASK 25-45-23-000-802-A
Removal of the Hand Grip of the Space Flex Lavatory
TASK 25-45-23-400-802-A
Installation of the Hand Grip of the Space Flex Lavatory
3. Job Set-up
Subtask 25-45-13-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the ground service network is energized
(Ref. AMM TASK 24-42-00-861-001).
   (2) Make sure that the aircraft electrical circuits are de-energized
(Ref. AMM TASK 24-41-00-862-002).
   (3) If necessary, remove the soap dispenser (Ref. AMM TASK 25-45-14-000-802).
   (4) If necessary, remove the hand grip (Ref. AMM TASK 25-45-23-000-802).
4. Procedure
Subtask 25-45-13-210-051-A ** ON A/C NOT FOR ALL
A. Preparation for Installation
   (1) Clean the component interfaces and the adjacent area.
   (2) Do a visual inspection of the component interfaces and the adjacent area.
   (3) Make sure that the parts retained from the removed component are clean and in the correct condition.
Subtask 25-45-13-420-052-A ** ON A/C NOT FOR ALL
B. Installation of the Mirror of the Space Flex Lavatory
F Mirror of the Space Flex Lavatory ** ON A/C NOT FOR ALL
   (1) Install the mirror (10) as follows:
     (a) Put the mirror (10) in position and push it to engage the pins (11) into the supports (12).
     (b) Make sure that the mirror (10) is installed correctly.
   (2) Install the mirror (1) as follows:
     (a) Put the mirror (1) in position and engage it on the clips (7).
     (b) If the electrical connectors (8) and (9) are safetied, release them from the lavatory.
     (c) Remove the CAP-BLANKING from each electrical connector and receptacle.
     (d) Make sure that all the electrical connections are clean and in the correct condition.
     (e) Connect the electrical connectors (8) and (9).
     (f) Install the washers (3) and the screws (4) on the brackets (2).
     (g) Tighten the screws (4).
     (h) Put the Passenger Service Unit (PSU) (5) in position and install the screws (6).
     (i) Tighten the screws (6).
5. Close-up
Subtask 25-45-13-410-052-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) If the soap dispenser is removed, install it (Ref. AMM TASK 25-45-14-400-802).
   (2) If the hand grip is removed, install it (Ref. AMM TASK 25-45-23-400-802).
   (3) Make sure that the work area is clean and clear of tools and other items.
Subtask 25-45-13-862-051-A ** ON A/C NOT FOR ALL
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).