Deactivation of the Galley Supply System
TASK 24-56-00-040-001-A
Deactivation of the Galley Supply System
MMEL 24-26-01B
GALLEY AUTOMATIC LOAD SHED SYSTEM
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 24-56-00-860-052-A ** ON A/C NOT FOR ALL
Subtask 24-56-00-040-050-A
Subtask 24-56-00-862-050-A
[Rev.10 from 2021]
2026.03.31 23:25:03 UTC
Deactivation of the Galley Supply System
Task Summary
1. Reason for the Job| Access | Test | Specific Tools | Mhr | E/T | Nb Men |
|---|---|---|---|---|---|
| NO | NO | NO | 0.3 | 0.3 | 1 |
MMEL 24-26-01B
GALLEY AUTOMATIC LOAD SHED SYSTEM
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| No specific | PLACARD |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 11-00-00-400-021-A | Installation of the Pressurized Area Placards |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 24-56-00-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the pushbutton switch GALLEY 2XA on the overhead panel 35VU is in the OFF position (white indication light shows OFF).
Subtask 24-56-00-860-052-B ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the pushbutton switch GALLEY 2XA on the overhead panel 35VU is in the OFF position (white indication light shows OFF).
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the pushbutton switch GALLEY 2XA on the overhead panel 35VU is in the OFF position (white indication light shows OFF).
(3) Make sure that the pushbutton switch ELEC/COMMERCIAL 22XN on the overhead panel 35VU is in the on position (white indication OFF is off).
Subtask 24-56-00-865-050-A (1) Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
(2) Make sure that the pushbutton switch GALLEY 2XA on the overhead panel 35VU is in the OFF position (white indication light shows OFF).
(3) Make sure that the pushbutton switch ELEC/COMMERCIAL 22XN on the overhead panel 35VU is in the on position (white indication OFF is off).
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | ELEC/GALLEY/CNTOR | 7MC | S28 |
| 122VU | ELEC/GALY & CAB/CTL | 1XA | S26 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AFT GALLEY/FEEDER A | 3MC | AF04 |
| ** ON A/C ALL | |||
| 123VU | FWD GALLEY/FEEDER F | 16MC | AC10 |
| 123VU | AFT GALLEY/FEEDER E | 14MC | AF09 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | AFT GALLEY/FEEDER B | 12MC | AD09 |
| 123VU | FWD GALLEY/FEEDER D | 2MC | AD04 |
| 123VU | FWD GALLEY/FEEDER C | 1MC | AE10 |
| ** ON A/C NOT FOR ALL | |||
| 123VU | FWD GALLEY/FEEDER D | 2MC | AE02 |
Subtask 24-56-00-040-050-A
A. Deactivation of the Galley Supply
(1) Make sure that the galley electrical panel(s) and galley equipment(s) does (do) not operate.
(2) Install a PLACARD "INOP" on the galley electrical panel(s) and galley equipment(s) to tell persons not to use it (Ref. AMM TASK 11-00-00-400-021).
(3) Make an entry in the logbook.
5. Close-up(1) Make sure that the galley electrical panel(s) and galley equipment(s) does (do) not operate.
(2) Install a PLACARD "INOP" on the galley electrical panel(s) and galley equipment(s) to tell persons not to use it (Ref. AMM TASK 11-00-00-400-021).
(3) Make an entry in the logbook.
Subtask 24-56-00-862-050-A