Installation of the Pressurized Area Placards
TASK 11-00-00-400-021-A
Installation of the Pressurized Area Placards
Self explanatory
2. Job Set-up Information
A. Consumable Materials
B. Referenced Information
3. Job Set-up
Subtask 11-00-00-110-072-A
Subtask 11-00-00-915-074-A
Subtask 11-00-00-942-072-A
[Rev.10 from 2021]
2026.03.31 22:53:51 UTC
Installation of the Pressurized Area Placards
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BBB1) | Non Aqueous Cleaner-- Petroleum Based - |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 11-00-00-110-072-A
A. Cleaning
(1) Clean and remove the grease from the surface on which you will bond the placard with Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) .
(2) Fully dry the surface you cleaned.
4. Procedure(1) Clean and remove the grease from the surface on which you will bond the placard with Non Aqueous Cleaner-- Petroleum Based - (Material No.08BBB1) .
(2) Fully dry the surface you cleaned.
Subtask 11-00-00-915-074-A
A. Installation of the Placards
(1) Make sure that the adjacent placards are aligned vertically and/or horizontally.
(2) If applicable, make sure that the distance between the placard and the egde or the corners of the surface is 20 mm (0.7874 in.)
(3) Make sure that you do not cause contamination to the mating surface of the placard. Do not touch this surface with your fingers.
(4) If necessary, drill the holes or cut the placard before you install it.
(5) Do not bond the placards at the corners.
(6) Apply pressure on the placard against the surface (specially on the edges) and at the same time gradually remove the backing paper.
(7) Carefully apply pressure on the placard from the center to the sides.
5. Close-up(1) Make sure that the adjacent placards are aligned vertically and/or horizontally.
(2) If applicable, make sure that the distance between the placard and the egde or the corners of the surface is 20 mm (0.7874 in.)
(3) Make sure that you do not cause contamination to the mating surface of the placard. Do not touch this surface with your fingers.
(4) If necessary, drill the holes or cut the placard before you install it.
(5) Do not bond the placards at the corners.
(6) Apply pressure on the placard against the surface (specially on the edges) and at the same time gradually remove the backing paper.
(7) Carefully apply pressure on the placard from the center to the sides.
Subtask 11-00-00-942-072-A
A. Make sure that the work area is clean and clear of tools and other items.
Installation of the Pressurized Area Placards