Visual Inspection of the Essential Transformer Rectifier (TR)
TASK 24-34-00-200-801-A
Visual Inspection of the Essential Transformer Rectifier (TR)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 24-34-00-861-050-A Subtask 24-34-00-010-051-A
Subtask 24-34-00-210-050-A
Subtask 24-34-00-410-051-A
[Rev.10 from 2021]
2026.03.31 23:23:29 UTC
Visual Inspection of the Essential Transformer Rectifier (TR)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 126 | LATERAL AVIONIC COMPARTMENT |
| 812 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-34-00-100-801-A | Cleaning of the Essential Transformer Rectifier (TR) |
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 24-34-00-861-050-A Subtask 24-34-00-010-051-A
B. Get access to the avionics compartment.
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below access door 812.
(2) Open access door 812 (Ref. AMM TASK 52-41-00-010-002).
(3) In the avionics compartment, open the access panel of AC/DC emergency power-center 106VU.
Subtask 24-34-00-865-057-A (1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position below access door 812.
(2) Open access door 812 (Ref. AMM TASK 52-41-00-010-002).
(3) In the avionics compartment, open the access panel of AC/DC emergency power-center 106VU.
C. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 106VU | ESS TR/SPLY | 4PE | C01 |
Subtask 24-34-00-210-050-A
A. Visual Inspection of the Essential TR
(1) Do a visual inspection of the essential TR (1) and the adjacent area:
(a) If there is a layer of dust or loose dirt on the ventilation grid area of the essential TR (1), clean it (Ref. AMM TASK 24-34-00-100-801).
Subtask 24-34-00-865-058-A (1) Do a visual inspection of the essential TR (1) and the adjacent area:
(a) If there is a layer of dust or loose dirt on the ventilation grid area of the essential TR (1), clean it (Ref. AMM TASK 24-34-00-100-801).
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 106VU | ESS TR/SPLY | 4PE | C01 |
Subtask 24-34-00-410-051-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) In the avionics compartment, close the access panel of AC/DC emergency power-center 106VU.
(3) Close access door 812 (Ref. AMM TASK 52-41-00-410-002).
(4) Remove the access platform(s).
Subtask 24-34-00-862-050-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) In the avionics compartment, close the access panel of AC/DC emergency power-center 106VU.
(3) Close access door 812 (Ref. AMM TASK 52-41-00-410-002).
(4) Remove the access platform(s).
Essential TR