Installation of the Power Unit for the Passenger Reading Light
TASK 23-73-38-400-001-A
Installation of the Power Unit for the Passenger Reading Light
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Expendable Parts
C. Referenced Information
3. Job Set-up
Subtask 23-73-38-861-051-A ** ON A/C NOT FOR ALL Subtask 23-73-38-865-051-A ** ON A/C NOT FOR ALL
Subtask 23-73-38-560-050-A ** ON A/C NOT FOR ALL
Subtask 23-73-38-862-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.03.31 23:18:21 UTC
Installation of the Power Unit for the Passenger Reading Light
1. Reason for the Job
Self Explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| 98A25208001000 | 1 | PULLEY ASSY-SEALING |
| AMP169994-1 | 1 | CRIMPING DEVICE |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 10 | TERMINAL-CABLE | AIPC 23-73-09-11-012 |
| 11 | HOUSING | AIPC 23-73-09-11-013 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 33-25-00-710-001-A | Operational Test of the Passenger Reading Light System |
Subtask 23-73-38-861-051-A ** ON A/C NOT FOR ALL Subtask 23-73-38-865-051-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
Subtask 23-73-38-865-053-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | PASSENGER READING LIGHT | 6LW | G06 |
| 2000VU | PASSENGER READING LIGHT | 5LW | G05 |
| 2000VU | PASSENGER READING LIGHT | 4LW | G04 |
| 2000VU | PASSENGER READING LIGHT | 3LW | G03 |
| 2000VU | PASSENGER READING LIGHT | 2LW | G02 |
| 2000VU | PASSENGER READING LIGHT | 1LW | G01 |
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | PASSENGER READING LIGHT | 6LW | G06 |
| 2000VU | PASSENGER READING LIGHT | 5LW | G05 |
| 2000VU | PASSENGER READING LIGHT | 4LW | G04 |
| 2000VU | PASSENGER READING LIGHT | 3LW | G03 |
| 2000VU | PASSENGER READING LIGHT | 2LW | G02 |
| 2000VU | PASSENGER READING LIGHT | 1LW | G01 |
Subtask 23-73-38-560-050-A ** ON A/C NOT FOR ALL
A. Preparation of the Replacement Component
(1) If necessary, make the electrical cable (6) shorter and install the electrical AIPC 23-73-09-11-012 TERMINAL-CABLE (10) with the AMP169994-1 CRIMPING DEVICE.
(2) Put the AIPC 23-73-09-11-013 HOUSING (11) over the cable terminal (10) and make sure that the housings engage correctly.
Subtask 23-73-38-420-050-A ** ON A/C NOT FOR ALL (1) If necessary, make the electrical cable (6) shorter and install the electrical AIPC 23-73-09-11-012 TERMINAL-CABLE (10) with the AMP169994-1 CRIMPING DEVICE.
(2) Put the AIPC 23-73-09-11-013 HOUSING (11) over the cable terminal (10) and make sure that the housings engage correctly.
B. Installation of the Power Unit for the Passenger Reading Light
(b) Clean the component interfaces and the adjacent area.
(c) Do an inspection of the component interfaces and the adjacent area.
(d) Carefully install the PCB (2) on the PSIU (1) with new plastic rivets (3).
(2) Connect the electrical connectors:
(b) Make sure that all the electrical connections are clean and in the correct condition.
(c) Connect the electrical connector (5) to the reading light (7).
(d) Connect the electrical connector (4) to the PCB (2).
(3) Close the PSIU.
(4) Make sure that the work area is clean and clear of tools and other items.
(5) Lift the PSIU (1) and engage it in the mounting rail (8).
(6) Install the section hose (9) with the 98A25208001000 PULLEY ASSY-SEALING to the mounting rail (8).
Subtask 23-73-38-865-066-A ** ON A/C NOT FOR ALL CAUTION:
BE CAREFUL WHEN YOU REMOVE OR INSTALL A PRINTED CIRCUIT BOARD. DO NOT TOUCH IT DIRECTLY. IT IS EASY TO CAUSE DAMAGE TO THIS COMPONENT.
(1) Install the power unit: NOTE: Be careful when you work on the lowered PSIU. If you use too much force, it is easy to move the PSIU in the mounting rail too much. This can cause damage to the hinge in the mounting rail.
(a) Make sure that the parts retained from the removed component are clean and in the correct condition.(b) Clean the component interfaces and the adjacent area.
(c) Do an inspection of the component interfaces and the adjacent area.
(d) Carefully install the PCB (2) on the PSIU (1) with new plastic rivets (3).
(2) Connect the electrical connectors:
CAUTION:
REFER TO THE MATCH MARKS MADE DURING THE REMOVAL WHEN YOU CONNECT THE ELECTRICAL WIRES.
INCORRECT CONNECTION OF THE WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
(a) Remove the CAP-BLANKING from each electrical connector and receptacle.(b) Make sure that all the electrical connections are clean and in the correct condition.
(c) Connect the electrical connector (5) to the reading light (7).
(d) Connect the electrical connector (4) to the PCB (2).
(3) Close the PSIU.
(4) Make sure that the work area is clean and clear of tools and other items.
(5) Lift the PSIU (1) and engage it in the mounting rail (8).
(6) Install the section hose (9) with the 98A25208001000 PULLEY ASSY-SEALING to the mounting rail (8).
NOTE: Make sure that the section hose is not expanded. Move the pulley assemble forward and rearward to prevent this.
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 23-73-38-710-050-A ** ON A/C NOT FOR ALL 5. Close-up| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | PASSENGER READING LIGHT | 6LW | G06 |
| 2000VU | PASSENGER READING LIGHT | 5LW | G05 |
| 2000VU | PASSENGER READING LIGHT | 4LW | G04 |
| 2000VU | PASSENGER READING LIGHT | 3LW | G03 |
| 2000VU | PASSENGER READING LIGHT | 2LW | G02 |
| 2000VU | PASSENGER READING LIGHT | 1LW | G01 |
Subtask 23-73-38-862-050-A ** ON A/C NOT FOR ALL
Power Unit - Removal/Installation