W DOC AIRBUS | AMM A320F

Deactivation of the Programming and Test Panel - Emergency System Test, Cabin Emergency Lighting System


TASK 23-73-00-040-007-A
Deactivation of the Programming and Test Panel - Emergency System Test, Cabin Emergency Lighting System


FIN: 110RH ** ON A/C NOT FOR ALL
Task Summary
Access Test Specific Tools Mhr E/T Nb Men
NONONO0.30.31
1. Reason for the Job
MMEL 23-74-01A
SYS TEST PB ON THE PTP (FAA ONLY)
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 11-00-00-400-021-A
Installation of the Pressurized Area Placards
TASK 23-73-00-740-005-A
BITE-Test of the Cabin Intercommunication Data System (CIDS) through the CFDS
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 33-51-00-040-001-A
Deactivation of the EMER SYSTEM TEST of the Cabin Emergency Lighting System
3. Job Set-up
Subtask 23-73-00-860-198-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001)
4. Procedure
Subtask 23-73-00-865-221-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/PROG &/TST PNL161RHM07
** ON A/C NOT FOR ALL
121VUCOM NAV/CIDS/PROG &/TST PNL161RHM08
Subtask 23-73-00-040-059-A ** ON A/C NOT FOR ALL
B. Procedure
   (1) In the cockpit:
   (2) In the cockpit, on the MCDU:
   (3) In the cockpit:
  • Lift the handset from the cradle.
  • Push and hold the PTT pushbutton switch and make an announcement.
   (4) In the cabin:
  • Make sure that you hear the announcement.
   (5) Install a placard "INOP" on the deactivated system to tell persons not to use it (Ref. AMM TASK 11-00-00-400-021).
   (6) Make an entry in the logbook.
[Rev.10 from 2021] 2026.03.31 23:16:59 UTC