Operational Test of the Boarding Music
TASK 23-33-00-710-819-A
Operational Test of the Boarding Music
Self explanatory.
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 23-33-00-861-093-A ** ON A/C NOT FOR ALL Subtask 23-33-00-010-095-A ** ON A/C NOT FOR ALL
Subtask 23-33-00-710-124-A ** ON A/C NOT FOR ALL
Subtask 23-33-00-860-181-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 05:24:52 UTC
Operational Test of the Boarding Music
ZONE: 220
1. Reason for the JobSelf explanatory.
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 220 | FWD CAB UTILITY AREAS |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 23-33-00-720-804-A | Start of the Flight Test |
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
Subtask 23-33-00-861-093-A ** ON A/C NOT FOR ALL Subtask 23-33-00-010-095-A ** ON A/C NOT FOR ALL
B. Get Access
(1) Open the applicable access door(s) to get access to Video Control Center (VCC) 10MH.
Subtask 23-33-00-865-248-A ** ON A/C NOT FOR ALL (1) Open the applicable access door(s) to get access to Video Control Center (VCC) 10MH.
C. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 23-33-00-860-180-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | OXYGEN/PASSENGER/ACTUATION | 7WR | HA08 |
| 49VU | OXYGEN/PASSENGER/ACTUATION | 6WR | HA07 |
| 49VU | OXYGEN/PASSENGER/ACTUATION | 5WR | HA06 |
| 49VU | OXYGEN/PASSENGER/ACTUATION | 4WR | HA05 |
| 49VU | OXYGEN/PASSENGER/CTL AND WARN | 3WR | HA04 |
| 49VU | OXYGEN/PASSENGER/CTL AND WARN | 2WR | HA03 |
| 49VU | OXYGEN/PASSENGER/CTL AND WARN | 1WR | HA02 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | IFE-IFEC-AC | 22MK | C04 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | INSEAT POWER-MCU 2 | 59HP | B08 |
| 2000VU | INSEAT POWER-MCU 1 | 58HP | B05 |
| 2000VU | IFE-VCC-AC | 21MH | C02 |
| 2000VU | IFE-VCC-DC | 20MH | C01 |
| 2000VU | IFE/SEAT-POWER-PAX SYS | 20MK | D08 |
| 2000VU | WAP | 27MH | D07 |
| ** ON A/C NOT FOR ALL | |||
| 2000VU | IFE-IFEC-AC | 22MK | C06 |
D. Aircraft Maintenance Configuration
(2) In the cabin, on all emergency oxygen containers, do step (a) and/or step (b) as applicable:
(a) Pull out the test button with your fingers. Then turn it 90 degrees to the TEST position.
(b) Push the left side of the test button on the door assembly.
4. ProcedureNOTE: The steps that follow are applicable for all Rave systems
(1) Do a Start of Flight Test (Ref. AMM TASK 23-33-00-720-804). (2) In the cabin, on all emergency oxygen containers, do step (a) and/or step (b) as applicable:
(a) Pull out the test button with your fingers. Then turn it 90 degrees to the TEST position.
(b) Push the left side of the test button on the door assembly.
NOTE: The over-center spring keeps the lever of the test button at 90 degrees to the door surface. The lever of the test button must stay in this position until you set it to the initial position.
Subtask 23-33-00-710-124-A ** ON A/C NOT FOR ALL
A. Operational Test of the Boarding Music
5. Close-up| ACTION | RESULT |
|---|---|
NOTE: The steps that follow are applicable for all Rave systems. 1.On removable DU 11MH, on the "Login/Welcome" page: | NOTE: The steps that follow are applicable for all Rave systems. On removable DU 11MH: |
|
|
| |
|
|
|
|
NOTE: Approximately two minutes are necessary to turn on the entertainment. |
|
| |
| 2.On removable DU 11MH: | On removable DU 11MH: |
|
|
| 3.On removable DU 11MH, on the application selection area: | On removable DU 11MH: |
|
|
| 4.On removable DU 11MH, on the "Boarding Music" page: | In the cabin: |
|
NOTE: The following step is applicable only for Rave Centric system and Rave mixed system.
NOTE: The following step is applicable only for Rave Wireless system and Rave mixed system.
|
NOTE: The following steps are applicable for all Rave systems. | NOTE: The following steps are applicable for all Rave systems. |
| 5.In the passenger compartment: | |
| |
| 6.In the cockpit, on the OXYGEN section of overhead panel 21VU: | In the cockpit, on the OXYGEN section of overhead panel 21VU: |
CAUTION:
DO NOT PUSH IN THE "MASK MAN ON" PUSHBUTTON SWITCH 14WR FOR MORE THAN 5 SECONDS.
|
|
| |
| | On removable DU 11MH and in the cabin:
NOTE: The following steps are applicable only for Rave Centric system and Rave mixed system.
NOTE: The following steps are applicable only for Rave Wireless system and Rave mixed system.
|
NOTE: The following steps are applicable for all Rave systems. | NOTE: The following steps are applicable for all Rave systems. |
| 7.In the cockpit, on the OXYGEN section of overhead panel 50VU: | In the cockpit, on the OXYGEN section of overhead panel 21VU: |
|
|
| | On removable DU 11MH and in the cabin: |
|
NOTE: The following steps are applicable only for Rave Centric system and Rave mixed system.
NOTE: The following steps are applicable only for Rave Wireless system and Rave mixed system.
|
Subtask 23-33-00-860-181-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to the serviceable condition.
(2) Make sure that the internal light of the PAX SYS switch goes off.
Subtask 23-33-00-410-093-A ** ON A/C NOT FOR ALL NOTE: The steps that follow are applicable for all Rave systems.
(1) Push the PAX SYS switch on VCC 10MH. (2) Make sure that the internal light of the PAX SYS switch goes off.
B. Close Access
(1) On all emergency oxygen containers:
(a) Close the doors of the emergency oxygen containers:
2 Push the door of the emergency oxygen container, at both sides of the test button, to lock the latch mechanism.
3 Make sure the door is flush with the adjacent panels.
4 Do step (b) and/or step (c) as applicable.
(b) Turn the test buttons 90 degrees to normal position.
(3) Make sure that the work area is clean and clear of tools and other items.
(4) Close the applicable access door(s) to VCC 10MH.
Subtask 23-33-00-862-089-A ** ON A/C NOT FOR ALL (1) On all emergency oxygen containers:
(a) Close the doors of the emergency oxygen containers:
CAUTION:
DO NOT USE TOO MUCH FORCE TO CLOSE THE EMERGENCY OXYGEN CONTAINER. IF YOU USE TOO MUCH FORCE, YOU CAN CAUSE DAMAGE TO THE LATCH MECHANISM. IF THE LATCH MECHANISM DOES NOT ENGAGE EASILY, MAKE SURE THAT THE EQUIPMENT IN THE EMERGENCY OXYGEN CONTAINER IS CORRECTLY INSTALLED.
1 Push the door of the emergency oxygen container to the closed position. 2 Push the door of the emergency oxygen container, at both sides of the test button, to lock the latch mechanism.
3 Make sure the door is flush with the adjacent panels.
4 Do step (b) and/or step (c) as applicable.
(b) Turn the test buttons 90 degrees to normal position.
NOTE: Spring tension will retract the test buttons automatically when they are in the normal position.
(c) Push the test buttons back to normal position and let them retract into their containers. NOTE: Spring tension will retract the test buttons automatically when they are in the normal position.
(2) Make sure that the switch guard is in position on the MASK MAN ON pushbutton switch. (3) Make sure that the work area is clean and clear of tools and other items.
(4) Close the applicable access door(s) to VCC 10MH.