W DOC AIRBUS | AMM A320F

Installation of the Recirculation Filter Housing


TASK 21-21-45-400-001-A
Installation of the Recirculation Filter Housing


WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGINE, THE APU OR A GROUND SOURCE. HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
ZONE: 137
FIN: 4010HM
FIN: 4011HM
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT)
No specific
AR
WARNING NOTICE(S)
FOR [4010HM] (RECIRC FILTER HOUSING 1)
No specific
AR
PLUG - BLANKING
FOR [4011HM] (RECIRC FILTER HOUSING 2)
No specific
AR
PLUG - BLANKING
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
137
BAY BETW AFT PART. BULKHEAD OF FWD CARGO
825
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 21-21-41-400-001-A
Installation of the Recirculation Filter Cartridge
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
FOR [4010HM] (RECIRC FILTER HOUSING 1)
TASK 25-54-12-000-001-A
Removal of the Forward Cargo-Compartment Partition
TASK 25-54-12-400-001-A
Installation of the Forward Cargo-Compartment Partition
TASK 06-41-53-00
FUSELAGE-DESCRIPTION AND OPERATION
FOR [4011HM] (RECIRC FILTER HOUSING 2)
TASK 25-54-12-000-001-A
Removal of the Forward Cargo-Compartment Partition
TASK 25-54-12-400-001-A
Installation of the Forward Cargo-Compartment Partition
TASK 06-41-53-00
FUSELAGE-DESCRIPTION AND OPERATION
3. Job Set-up
Subtask 21-21-45-861-051-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
   (2) On the AIR COND panel 30VU, make sure that:
     (a) The APU BLEED pushbutton switch is released (the ON legend is off).
     (b) The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are released (the OFF legends are on).
     (c) The warning notice to tell persons not to operate these pushbutton switches is in position.
   (3) On the HP and the LP ground connectors:
     (a) Make sure that the WARNING NOTICE(S) to tell persons not to supply air from a ground air source is in position.
   (4) Make sure that the FWD cargo-compartment door 825 is open (Ref. AMM TASK 52-30-00-860-001).
   (5) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the FWD cargo-compartment door 825.
   (6) FOR [4010HM] (RECIRC FILTER HOUSING 1)
   (7) FOR [4011HM] (RECIRC FILTER HOUSING 2)
Subtask 21-21-45-861-051-B ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
   (2) On the AIR COND panel 30VU, make sure that:
     (a) The APU BLEED pushbutton switch is released (the ON legend is off).
     (b) The ENG 1 BLEED and the ENG 2 BLEED pushbutton switches are released (the OFF legends are on).
     (c) The warning notice to tell persons not to operate these pushbutton switches is in position.
   (3) On the HP and the LP ground connectors:
     (a) Make sure that the WARNING NOTICE(S) to tell persons not to supply air from a ground air source is in position.
   (4) Make sure that the FWD cargo-compartment door 825 is open (Ref. AMM TASK 52-30-00-860-001).
   (5) Make sure that the ACCESS PLATFORM 2M (6 FT) is in position at the FWD cargo-compartment door 825.
   (6) FOR [4010HM] (RECIRC FILTER HOUSING 1)
   (7) FOR [4011HM] (RECIRC FILTER HOUSING 2)
Subtask 21-21-45-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 4010HM (RECIRC FILTER HOUSING 1)
122VUAIR COND/RECIRC FAN/L/CTL2HGX20
122VUAIR COND/RECIRC FAN/L/SPLY1HGX18
FOR FIN: 4011HM (RECIRC FILTER HOUSING 2)
122VUAIR COND/RECIRC FAN/R/CTL11HGW20
122VUAIR COND/RECIRC FAN/R/SPLY3HGW18
4. Procedure
Subtask 21-21-45-420-050-A
A. Installation of the Recirculation Filter Housing
   (1) FOR [4010HM] (RECIRC FILTER HOUSING 1)
     (a) Remove the PLUG - BLANKING from the disconnected line end(s).
     (b) Put the recirculation filter housing (1) in the correct position between the supports (2), (3) and (14).
     (c) Install the four washers (15) and the four bolts (16).
       1 Tighten the four bolts (16).
     (d) Install the two washers (4) and the two bolts (5).
       1 Tighten the two bolts (5).
     (e) Install the two washers (7) and the two bolts (6).
       1 Tighten the two bolts (6).
     (f) Install the two washers (9), the two bolts (8), the two washers (12) and the two nuts (13).
       1 Tighten the two nuts (13).
     (g) Install the tube (10) with the clamp (11) on the recirculation filter housing (1).
     (h) Tighten the nut of the clamp (11).
   (2) FOR [4011HM] (RECIRC FILTER HOUSING 2)
     (a) Remove the PLUG - BLANKING from the disconnected line end(s).
     (b) Put the recirculation filter housing (18) in the correct position between the supports (17), (21) and (26).
     (c) Install the four washers (19) and the four bolts (20).
       1 Tighten the four bolts (20).
     (d) Install the four washers (36) and the four bolts (37).
       1 Tighten the four bolts (37).
     (e) Install the three washers (22) and the three bolts (23).
       1 Tighten the three bolts (23).
     (f) Install the three washers (25) and the three bolts (24).
       1 Tighten the three bolts (24).
     (g) Install the three washers (33), the three bolts (34), the three washers (30) and the three nuts (29).
       1 Tighten the three nuts (29).
     (h) Install the three washers (32), the three bolts (31), the three washers (28) and the three nuts (27).
       1 Tighten the three nuts (27).
5. Close-up
Subtask 21-21-45-420-051-A
A. Install the related recirculation filter (Ref. AMM TASK 21-21-41-400-001).
Subtask 21-21-45-410-050-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) FOR [4010HM] (RECIRC FILTER HOUSING 1)
   (3) FOR [4011HM] (RECIRC FILTER HOUSING 2)
   (4) Remove the access platform.
   (5) Close the FWD cargo-compartment door 825.
   (6) Remove the WARNING NOTICE(S).
Subtask 21-21-45-410-050-B ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) FOR [4010HM] (RECIRC FILTER HOUSING 1)
   (3) FOR [4011HM] (RECIRC FILTER HOUSING 2)
   (4) Remove the access platform.
   (5) Close the FWD cargo-compartment door 825.
   (6) Remove the WARNING NOTICE(S).
Subtask 21-21-45-865-052-A
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
FOR FIN: 4010HM (RECIRC FILTER HOUSING 1)
122VUAIR COND/RECIRC FAN/L/CTL2HGX20
122VUAIR COND/RECIRC FAN/L/SPLY1HGX18
FOR FIN: 4011HM (RECIRC FILTER HOUSING 2)
122VUAIR COND/RECIRC FAN/R/CTL11HGW20
122VUAIR COND/RECIRC FAN/R/SPLY3HGW18
Subtask 21-21-45-862-050-A
D. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 06:52:47 UTC