W DOC AIRBUS | AMM A320F

Operational Test of the Cabin Recirculation Fans


TASK 21-21-00-710-001-A
Operational Test of the Cabin Recirculation Fans


FIN: 14HG
FIN: 15HG
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-002-A
Procedure to Get Access to the SYSTEM REPORT/TEST/AIR COND Page
3. Job Set-up
Subtask 21-21-00-861-052-A
A. Energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-861-002).
NOTE: The energization of the aircraft electrical circuits starts a full test of the pack, cockpit and cabin temperature-control systems.
Subtask 21-21-00-865-056-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR COND/TEMP CTL/SYS 1 CHAN B/28VDC52HHD08
** ON A/C NOT FOR ALL
122VUAIR COND/ZONE TEMP CTL/28VDC/SYS24HKV20
122VUAIR COND/ZONE TEMP CTL/28VDC/SYS13HKV19
122VUAIR COND/ZONE TEMP CTL/115VAC/SYS22HKV18
122VUAIR COND/ZONE TEMP CTL/115VAC/SYS11HKV17
122VUAIR COND/PACK TEMP/CTL SYS1/2/115VAC21HHW22
122VUAIR COND/PACK TEMP/CTL SYS1/2/28VDC23HHW21
122VUAIR COND/PACK TEMP/CTL SYS1/1/115VAC1HHX22
122VUAIR COND/PACK TEMP/CTL SYS1/1/28VDC3HHX21
122VUAIR COND/PACK TEMP CTL SYS2/2/28VDC24HHY21
122VUAIR COND/PACK TEMP CTL SYS2/2/115VAC22HHY20
122VUAIR COND/PACK TEMP CTL SYS2/1/28VDC4HHY19
122VUAIR COND/PACK TEMP CTL SYS2/1/115VAC2HHY18
** ON A/C ALL
122VUAIR COND/RECIRC FAN/R/CTL11HGW20
122VUAIR COND/RECIRC FAN/R/SPLY3HGW18
122VUAIR COND/RECIRC FAN/L/CTL2HGX20
122VUAIR COND/RECIRC FAN/L/SPLY1HGX18
** ON A/C NOT FOR ALL
122VUAIR COND/TEMP CTL SYS 2/CHAN A/115VAC53HHW22
122VUAIR COND/TEMP CTL SYS 2/CHAN A/28VDC55HHW21
122VUAIR COND/TEMP CTL SYS 1/CHAN A/115VAC49HHX22
122VUAIR COND/TEMP CTL SYS 1/CHAN A/28VDC51HHX21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/28VDC56HHY21
122VUAIR COND/TEMP CTL SYS 2/CHAN B/115VAC54HHY20
122VUAIR COND/TEMP CTL SYS 1/CHAN B/115VAC50HHY18
Subtask 21-21-00-860-056-A
C. Aircraft Maintenance Configuration
   (1) On the panel 30VU push the PACK 1 and the PACK 2 pushbutton switches to the off position (the OFF legends come on).
   (2) On the panel 22VU make sure that the CAB FANS switch is in the on position (the OFF legend shows off).
   (3) On one MCDU get the SYSTEM REPORT/TEST AIR COND menu page (Ref. AMM TASK 31-32-00-860-002).
4. Procedure
Subtask 21-21-00-710-052-B ** ON A/C NOT FOR ALL
A. Operational Test of the Cabin Recirculation Fans
ACTION
RESULT
1.On the AIR COND menu page:
On the MCDU:
  • push the line key adjacent to the TEMP CTL indication.
  • the CAB TEMP CONT menu page comes on.
2.On the CAB TEMP CONT menu page:

  • push the line key adjacent to the TEST indication.
  • the CAB TEMP CONT TEST page comes on.
  • the message SELECT PACK 1 AND 2 OFF comes on
3.On the CAB TEMP CONT TEST page:

  • push the line key adjacent to the CONTINUE indication.
  • the message IN PROGRESS MAX 300 S comes on, then the messages TEST OK and END OF TEST comes on.
  • push the MCDU MENU key.
  • the MCDU MENU page comes on.
4.On the MCDU MENU page:

  • push the line key adjacent to the CFDS indication.
  • the CFDS page comes on.
5.On the CFDS page:

  • push the line key adjacent to the AVIONICS STATUS.
  • the AVIONICS STATUS page with no TEMP CTL (CLASS 3) message comes on.
NOTE: Ignore the CLASS 3 failures on the CAB TEMP CONT CLASS 3 FAULTS page which are not related to the air distribution (ATA 21-21).
Subtask 21-21-00-710-052-C ** ON A/C NOT FOR ALL
A. Operational Test of the Cabin Recirculation Fans
   (1) Make sure that all bleed air sources (Engine, APU and/or HP ground supply) are disconnected or shut down.
NOTE: The presence of bleed air pressure in the system could lead to test performance failure.
ACTION
RESULT
1.On the AIR COND menu page:
On the MCDU:
  • push the line key adjacent to the TEMP CTL indication.
  • the CAB TEMP CONT menu page comes on.
2.On the CAB TEMP CONT menu page:

  • push the line key adjacent to the TEST indication.
  • the CAB TEMP CONT SYSTEM TEST page comes on.
  • the message SELECT PACK 1 AND 2 OFF comes on
3.On the CAB TEMP CONT SYSTEM TEST page:

  • push the line key adjacent to the START TEST indication.

4.On the CAB TEMP CONT SYSTEM TEST page:

  • push the line key adjacent to the CONFIRM START OF TEST indication.
  • the message TEST IN PROGRESS 240 S comes on, then the message TEST OK comes on.
  • push the MCDU MENU key.
  • the MCDU MENU page comes on.
5.On the MCDU MENU page:

  • push the line key adjacent to the CFDS indication.
  • the CFDS page comes on.
6.On the CFDS page:

  • push the line key adjacent to the AVIONICS STATUS.
  • the AVIONICS STATUS page with no TEMP CTL (CLASS 3) message comes on.
NOTE: Ignore the CLASS 3 failures on the CAB TEMP CONT CLASS 3 FAULTS page which are not related to the air distribution (ATA 21-21).
5. Close-up
Subtask 21-21-00-860-055-A
A. Aircraft Maintenance Configuration
   (1) On the panel 30VU push the PACK 1 and the PACK 2 pushbutton switches to the on position (the OFF legends go off).
   (2) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
   (3) De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.03.31 23:00:47 UTC