W DOC AIRBUS | AMM A320F

Procedure to Get Access to the SYSTEM REPORT/TEST/AIR COND Page


TASK 31-32-00-860-002-A
Procedure to Get Access to the SYSTEM REPORT/TEST/AIR COND Page


WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT. UNWANTED ELECTRICAL POWER CAN BE DANGEROUS.
NOTE: IGNORE ALL THE ECAM WARNINGS AS LONG AS THE COMPUTER IS IN THE MENU MODE.
ZONE: 210
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
210
CKPT,FWD COMPT BHD TO FLT COMPT BULKHEAD
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
3. Job Set-up
Subtask 31-32-00-860-058-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002)
Subtask 31-32-00-865-064-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAUTO FLT/MCDU/111CA1B01
** ON A/C NOT FOR ALL
49VUAUTO FLT/MCDU/111CA1H07
** ON A/C NOT FOR ALL
121VUCFDS/CFDIU/SPLY2TWJ18
121VUCFDS/CFDIU/BACK/UP8TWJ17
** ON A/C ALL
121VUAUTO FLT/MCDU/211CA2N20
** ON A/C NOT FOR ALL
121VUCFDS/CFDIU/SPLY2TWJ41
121VUCFDS/CFDIU/BACK/UP8TWJ40
4. Procedure
Subtask 31-32-00-860-059-D ** ON A/C NOT FOR ALL
A. This procedure permits to get access to the systems below:
  • CPC 1
  • CPC 2
  • TEMP CTL
  • AEVC
Subtask 31-32-00-860-059-E ** ON A/C NOT FOR ALL
A. This procedure permits to get access to the systems below:
  • CPC 1
  • CPC 2
  • TEMP CTL
  • AEVC
  • AFT CHC
Subtask 31-32-00-860-059-H ** ON A/C NOT FOR ALL
A. This procedure permits to get access to the systems below:
  • CPC 1
  • CPC 2
  • TEMP CTL
  • AEVC
  • CSAC *

(* optional system)
Subtask 31-32-00-860-059-I ** ON A/C NOT FOR ALL
A. This procedure permits to get access to the systems below:
  • CPC 1
  • CPC 2
  • TEMP CTL
  • AEVC
  • AFT CHC *
  • CSAC *

(* optional system)
Subtask 31-32-00-860-060-A ** ON A/C NOT FOR ALL
B. Access to the SYSTEM REPORT/TEST/AIR COND page

NOTE: The procedure below is applicable to the MCDU 1 or 2.
The actions and the results of this procedure occur on the MCDU used.
ACTION
RESULT
Adjust the brightness of the MCDU screen.

  • push the MCDU MENU mode key
On the MCDU:
  • the MCDU MENU page comes into view.
  • push the line key adjacent to the CFDS indication.
the CFDS MENU page comes into view.
  • push the line key adjacent to the SYSTEM REPORT/TEST indication.
the SYSTEM REPORT/TEST page comes into view.
  • push the line key adjacent to the AIR COND indication.
the SYSTEM REPORT/TEST/AIR COND page comes into view.
Subtask 31-32-00-860-060-C ** ON A/C NOT FOR ALL
B. Access to the SYSTEM REPORT/TEST/AIR COND page

NOTE: The procedure below is applicable to the MCDU 1 or 2.
The actions and the results of this procedure occur on the MCDU used.
ACTION
RESULT
Adjust the brightness of the MCDU screen.

  • push the MCDU MENU mode key
On the MCDU:
  • the MCDU MENU page comes into view.
  • push the line key adjacent to the CFDS indication.
the CFDS MENU page comes into view.
  • push the line key adjacent to the SYSTEM REPORT/TEST indication.
the SYSTEM REPORT/TEST page comes into view.
  • push the line key adjacent to the AIR COND indication.
the SYSTEM REPORT/TEST/AIR COND page comes into view.
  • if the page shown is not applicable, push the NEXT PAGE function key.

[Rev.10 from 2021] 2026.04.01 04:54:58 UTC