22-63 YAW DAMPER COMPUTATION
- PB.201 YAW DAMPER COMPUTATION - FAULT ISOLATION PROCEDURES
-
22-63-00-810-801-A
[8]
Loss of the Yaw Damper Function on the FAC 1 -
22-63-00-810-802-A
[8]
Loss of the Yaw Damper Function on the FAC 2 -
22-63-00-810-803-A
[8]
Loss of the Reception of the YD ENGD Feedback Discrete by the FAC 1 -
22-63-00-810-804-A
[8]
Loss of the Reception of the YD ENGD Feedback Discrete by the FAC 2 -
22-63-00-810-805-A
[8]
Loss of the Signal from the Yaw-Damper Position Transducer-Unit to the FAC 1 -
22-63-00-810-806-A
[8]
Loss of the Signal from the Yaw-Damper Position Transducer-Unit to the FAC 2 -
22-63-00-810-807-A
[8]
Loss of the Power Supply 26VAC of the Yaw Damper Side 1 -
22-63-00-810-808-A
[8]
Loss of the Power Supply 26VAC of the Yaw Damper Side 2 -
22-63-00-810-809-A
[8]
FAC 1 YD Function Inoperative -
22-63-00-810-810-A
[8]
FAC 2 YD Function Inoperative -
22-63-00-810-811-A
[8]
Loss of the Reception of the HYD CIRC PRESS SW Discrete by the FAC 1 -
22-63-00-810-812-A
[8]
Loss of the Reception of the HYD CIRC PRESS SW Discrete by the FAC 2 -
22-63-00-810-815-A
[8]
Loss of the Yaw Damper Function
-
22-63-00-810-801-A
[8]