W DOC AIRBUS | TSM A320F

Loss of the Signal from the Yaw-Damper Position Transducer-Unit to the FAC 2


TASK 22-63-00-810-806-A
Loss of the Signal from the Yaw-Damper Position Transducer-Unit to the FAC 2


1. Possible Causes
  • FAC-2 [1CC2]
  • wiring of the 26VAC signal at RVDT box (2CC)
  • wiring of the ground signal at RVDT box (2CC)
  • XDCR UNIT-YAW DAMPER POS [2CC]
  • wirings of the YAW V1 MON and YAW V2 MON discretes (from the RVDT box (2CC) to the FAC 2 (1CC2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-63-00-710-001
Operational Test of the Yaw Damper Function
AMM 22-66-34-000-002
Removal of the FAC
AMM 22-66-34-400-002
Installation of the FAC
ASM 226804
AMM 22-96-00-710-001
Operational Test of the AFS
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 27-26-17-000-001
Removal of the Yaw Damper Position Transducer Unit
AMM 27-26-17-400-001
Installation of the Yaw Damper Position Transducer Unit
AMM 29-10-00-863-003
Pressurize the Blue Hydraulic System with a Hydraulic Ground Power-Cart
AMM 29-23-00-863-001
Pressurize the Green Hydraulic System from the Yellow Hydraulic System through the PTU with the Electric Pump
AMM 29-24-00-863-001
Pressurize the Yellow Hydraulic System with the Electric Pump
3. Fault Confirmation
WARNING: MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.
WARNING: MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROL SURFACES ARE CLEAR BEFORE YOU PRESSURIZE/DEPRESSURIZE A HYDRAULIC SYSTEM.
Subtask 22-63-00-860-053-A
A. Job Set-Up
   (1) Aircraft Maintenance Configuration
     (a) Energize the aircraft electrical circuits
AMM 24-41-00-861-002.
     (b) Pressurize the aircraft hydraulic systems
AMM 29-23-00-863-001 AMM 29-24-00-863-001 AMM 29-10-00-863-003.
Subtask 22-63-00-865-053-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAUTO FLT/FAC2/28VDC5CC2M19
Subtask 22-63-00-710-062-A
C. Test
   (1) Open the circuit breaker 5CC2.
   (2) After a minimum of 10 seconds, close the circuit breaker 5CC2.
   (3) After 2 minutes, do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FAC 2.
4. Fault Isolation
Subtask 22-63-00-810-057-A
A. If the test gives the maintenance message AFS : FAC2/YD RVDT BOX 2CC:
   (1) If the fault continues:
  • do a check of the wiring of the 26VAC signal at RVDT box (2CC) from pin B/A to the first terminal block ASM 226804.
     (a) If there is no continuity:
  • repair the above wiring.
     (b) If there is continuity:
  • do a check of the wiring of the ground signal at RVDT box (2CC) pin B/B ASM 226804.
       1 If there is no continuity:
  • repair the above wiring.
       2 If there is continuity:
   (2) If the fault continues:
  • do a check and repair the wirings of the YAW V1 MON and YAW V2 MON discretes (from the RVDT box (2CC) to the FAC 2 (1CC2) ASM 226804.
Subtask 22-63-00-710-063-A
B. Do the operational test of the yaw damper function AMM 22-63-00-710-001.
[Rev.8 from Aug 2018] 2026.04.04 04:25:13 UTC