Loss of the Reception of the YD ENGD Feedback Discrete by the FAC 1


TASK 22-63-00-810-803-A
Loss of the Reception of the YD ENGD Feedback Discrete by the FAC 1


1. Possible Causes
  • FAC-1 [1CC1]
  • wiring of the YAW ENGD COM and YAW ENGD MON discretes (from the FAC 1 (1CC1) to the first terminal block)
  • wiring of the YAW OWN ENGD COM and YAW OWN ENGD MON discretes (from the FAC 1 (1CC1) to the first terminal block)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 22-60-00-710-002
Operational Test of the Automatic Change-Over Function
AMM 22-66-34-000-002
Removal of the FAC
AMM 22-66-34-400-002
Installation of the FAC
ASM 226804
AMM 22-96-00-710-001
Operational Test of the AFS
3. Fault Confirmation
Subtask 22-63-00-710-056-A
A. Test
   (1) Do the operational test of the AFS AMM 22-96-00-710-001 and read the result for the FAC 1.
   (2) Do the operational test of the automatic change-over function AMM 22-60-00-710-002.
4. Fault Isolation
Subtask 22-63-00-810-054-A
A. If the operational test of the AFS gives the maintenance message AFS: FAC1/YD ENGD FDBK:
   (1) If the operational test of the automatic change-over function gives the maintenance message AFS: FAC2/YD ENGD CHG-OV:
     (a) If the fault continues:
  • do a check and repair the wiring of the YAW ENGD COM and YAW ENGD MON discretes (from the FAC 1 (1CC1) to the first terminal block), ASM 226804.
   (2) If the operational test of the automatic change-over function does not give the maintenance message AFS: FAC2/YD ENGD CHG-OV:
     (a) If the fault continues:
  • do a check and repair the wiring of the YAW OWN ENGD COM and YAW OWN ENGD MON discretes (from the FAC 1 (1CC1) to the first terminal block), ASM 226804.
Subtask 22-63-00-710-057-A
B. Do the test given in Para. 3.A.(1).