FAC 1 YD Function Inoperative
TASK 22-63-00-810-809-A
FAC 1 YD Function Inoperative
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-63-00-710-068-A 4. Fault Isolation
Subtask 22-63-00-810-060-B
[Rev.8 from Aug 2018]
2026.04.04 04:25:14 UTC
FAC 1 YD Function Inoperative
1. Possible Causes
- FAC 1
- FMGC 1
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 22-91-00-710-001 | Ground Scanning of the AFS |
| AMM 22-96-00-710-001 | Operational Test of the AFS |
| AMM 22-97-00-710-001 | Operational Test of the LAND CAT III Capability |
Subtask 22-63-00-710-068-A 4. Fault Isolation
Subtask 22-63-00-810-060-B
A. If the test gives the maintenance message AFS: CHECK FAC1 YD:
(2) If the test does not gives the maintenance message, or if the fault continues:
Subtask 22-63-00-710-069-A - do the Ground Scanning of the AFS AMM 22-91-00-710-001.
(2) If the test does not gives the maintenance message, or if the fault continues:
- do the operational test of the AFS AMM 22-96-00-710-001 and read the results for the FAC 1 and the FMGC 1 .
B. Do the test given in Para. 3.