Loss of the Power Supply 26VAC of the Yaw Damper Side 2
TASK 22-63-00-810-808-A
Loss of the Power Supply 26VAC of the Yaw Damper Side 2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 22-63-00-710-066-A 4. Fault Isolation
Subtask 22-63-00-810-059-A
[Rev.8 from Aug 2018]
2026.04.04 04:25:14 UTC
Loss of the Power Supply 26VAC of the Yaw Damper Side 2
1. Possible Causes
- SERVO ACTR-YAW DAMPER, 2 [3CC2]
wiring of the 26VAC signal at yaw-damper servo-actuator (3CC2) wiring of the ground signal at yaw-damper servo-actuator (3CC2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 226701 | |
| AMM 22-91-00-710-001 | Ground Scanning of the AFS |
| AMM 27-23-51-000-001 | Removal of the Rudder Travel Limitation Unit |
| AMM 27-23-51-400-001 | Installation of the Rudder Travel-Limitation Unit |
Subtask 22-63-00-710-066-A 4. Fault Isolation
Subtask 22-63-00-810-059-A
A. If the test gives the maintenance message AFS : 231 XPA BUS BAR:
Subtask 22-63-00-710-067-A - replace the SERVO ACTR-YAW DAMPER, 2 [3CC2] , AMM 27-23-51-000-001 and AMM 27-23-51-400-001.
- do a check of the
wiring of the 26VAC signal at yaw-damper servo-actuator (3CC2) from pin A/A to the first terminal block ASM 226701.
- repair the above wiring.
- do a check and repair the
wiring of the ground signal at yaw-damper servo-actuator (3CC2) pin A/L ASM 226701.
B. Do the test given in Para. 3.