Loss of the Power Supply 26VAC of the Yaw Damper Side 2


TASK 22-63-00-810-808-A
Loss of the Power Supply 26VAC of the Yaw Damper Side 2


1. Possible Causes
  • SERVO ACTR-YAW DAMPER, 2 [3CC2]
  • wiring of the 26VAC signal at yaw-damper servo-actuator (3CC2)
  • wiring of the ground signal at yaw-damper servo-actuator (3CC2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 226701
AMM 22-91-00-710-001
Ground Scanning of the AFS
AMM 27-23-51-000-001
Removal of the Rudder Travel Limitation Unit
AMM 27-23-51-400-001
Installation of the Rudder Travel-Limitation Unit
3. Fault Confirmation
Subtask 22-63-00-710-066-A
A. Test
   (1) Do the Ground Scanning of the AFS AMM 22-91-00-710-001.
4. Fault Isolation
Subtask 22-63-00-810-059-A
A. If the test gives the maintenance message AFS : 231 XPA BUS BAR:
   (1) If the fault continues:
  • do a check of the wiring of the 26VAC signal at yaw-damper servo-actuator (3CC2) from pin A/A to the first terminal block ASM 226701.
     (a) If there is no continuity:
  • repair the above wiring.
     (b) If there is continuity:
  • do a check and repair the wiring of the ground signal at yaw-damper servo-actuator (3CC2) pin A/L ASM 226701.
Subtask 22-63-00-710-067-A
B. Do the test given in Para. 3.