W DOC AIRBUS | TSM A320F

Loss of the Yaw Damper Function


TASK 22-63-00-810-815-A
Loss of the Yaw Damper Function


1. Possible Causes
  • SW-LOW OIL PRESS [4000EN]
  • 1801VD
  • 1800VD
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 22-63-00-810-801-A
Loss of the Yaw Damper Function on the FAC 1
TSM TASK 22-63-00-810-802-A
Loss of the Yaw Damper Function on the FAC 2
AWM 226830
AMM 71-00-00-710-028
Engine Shutdown
AMM 79-34-15-000-040
Removal of the Low Oil Pressure Switch
AMM 79-34-15-000-041
Removal of the Low Oil Pressure Switch
AMM 79-34-15-400-040
Installation of the Low Oil Pressure Switch
AMM 79-34-15-400-041
Installation of the Low Oil Pressure Switch
3. Fault Confirmation
Subtask 22-63-00-710-076-A
A. Not applicable.
Subtask 22-63-00-865-054-A
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAUTO FLT/FAC1/28VDC5CC1B04
121VUAUTO FLT/FAC2/28VDC5CC2M19
4. Fault Isolation
Subtask 22-63-00-810-064-A ** ON A/C NOT FOR ALL
A. If the ECAM warning AUTO FLT YAW DAMPER 1, AUTO FLT YAW DAMPER 2 or AUTO FLT YAW DAMPER SYS comes into view, at or after engine start:
   (1) Do a reset of:
  • FAC 1 with the FLT CTL/FAC 1 pushbutton switch (on panel 25VU), and
  • FAC 2 with the FLT CTL/FAC 2 pushbutton switch (on panel 24VU).
   (2) If the fault continues:
  • Shut down the engines AMM 71-00-00-710-028 and do a reset of the circuit breakers 5CC1 and 5CC2 (for more than 5 seconds).
   (3) If the fault continues:
   (4) If the fault continues:
   (5) If the fault continues:
   (6) If the fault continues:
Subtask 22-63-00-810-064-D ** ON A/C NOT FOR ALL
A. If the ECAM warning AUTO FLT YAW DAMPER 1, AUTO FLT YAW DAMPER 2 or AUTO FLT YAW DAMPER SYS comes into view, at or after engine start:
   (1) Do a reset of:
  • FAC 1 with the FLT CTL/FAC 1 pushbutton switch (on panel 25VU), and
  • FAC 2 with the FLT CTL/FAC 2 pushbutton switch (on panel 24VU).
   (2) If the fault continues:
  • Shut down the engines AMM 71-00-00-710-028 and do a reset of the circuit breakers 5CC1 and 5CC2 (for more than 5 seconds).
   (3) If the fault continues:
   (4) If the fault continues:
   (5) If the fault continues:
   (6) If the fault continues:
[Rev.8 from Aug 2018] 2026.04.04 04:25:15 UTC