Fill the Starter with Oil [PW11]
TASK 80-11-00-600-801-A
Fill the Starter with Oil
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 80-11-00-941-063-A ** ON A/C NOT FOR ALL
Subtask 80-11-00-410-062-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 12:57:09 UTC
Fill the Starter with Oil
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 400
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | CONTAINER 20L (5 USGAL) |
| No specific | Torque wrench: range to between 100 and 90 lbf.in (1.13 and 1.02 m.daN ) ![]() |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.P03-001) | lubricant, aircraft turbine engine |
| (Material No.P05-005) | lint-free cotton cloth |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR, 452AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR, 462AR | |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 3 | PREFORMED PACKING | EIPC 80-11-01-01-130 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-802-A | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-805-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
| TASK 78-36-00-010-802-A | Opening of the Thrust Reverser Cowl-Doors |
| TASK 78-36-00-410-802-A | Closing of the Thrust Reverser Cowl-Doors |
Subtask 80-11-00-941-063-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833)
Subtask 80-11-00-010-062-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833)
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR.
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR.
Subtask 80-11-00-040-054-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR.
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR.
C. Deactivation of the Thrust Reverser for Ground Maintenance
Subtask 80-11-00-010-063-A ** ON A/C NOT FOR ALL WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Do the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-805). D. Get Access
(1) Open the right thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR.
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR.
4. Procedure(1) Open the right thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR.
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR.
CAUTION:
WIPE CLEAN ALL PARTS AND TOOLS AS NECESSARY TO REMOVE UNWANTED DEBRIS AND PREVENT DAMAGE TO THE ENGINE.
Subtask 80-11-00-612-050-A ** ON A/C NOT FOR ALL A. Fill the Starter with Oil
(1) Find the starter located approximately at the 5 o'clock position attached to the Main Gearbox (MGB).
(2) Remove the oil fill plug from the starter as follows:
(a) Loosen the fill plug retention bolt (1) on the starter.
(b) Turn the fill plug (2) to disengage the retention tab from under the bolt (1).
(c) Remove the fill plug (2) as follows:
(d) Remove and discard the packing (3).
(e) Clean the fill plug with a lint-free cotton cloth (Material No.P05-005) .
(3) Fill the starter with oil as follows:
(a) Put a CONTAINER 20L (5 USGAL) under the starter.
(b) Fill the starter with 16 fl. oz. (473.2 ml) to 20 fl. oz. (591.4 ml) ofP03-001 lubricant, aircraft turbine engine .
(4) Install the fill plug (2) to the starter as follows:
(a) ApplyP03-001 lubricant, aircraft turbine engine to a new EIPC 80-11-01-01-130 PREFORMED PACKING (3).
(b) Install the EIPC 80-11-01-01-130 PREFORMED PACKING (3) on the fill plug (2).
(c) Install the fill plug (2) to the starter as follows:
2 Make sure the fill plug (2) is fully seated against the mating surface.
3 Turn the fill plug (2) so the retention tab is under the bolt (1).
4 TORQUE the fill plug retention bolt (1) to between 100 and 90 lbf.in (1.13 and 1.02 m.daN )
.
5. Close-up(1) Find the starter located approximately at the 5 o'clock position attached to the Main Gearbox (MGB).
(2) Remove the oil fill plug from the starter as follows:
(a) Loosen the fill plug retention bolt (1) on the starter.
(b) Turn the fill plug (2) to disengage the retention tab from under the bolt (1).
(c) Remove the fill plug (2) as follows:
CAUTION:
DO NOT PRY ON THE RETENTION TAB TO REMOVE THE FILL PLUG. IF YOU DO NOT OBEY THIS INSTRUCTION, DAMAGE TO THE FILL PLUG CAN OCCUR.
1 Hold the fill plug (2) by the square, turn and pull it as necessary to remove it from the starter. (d) Remove and discard the packing (3).
(e) Clean the fill plug with a lint-free cotton cloth (Material No.P05-005) .
(3) Fill the starter with oil as follows:
(a) Put a CONTAINER 20L (5 USGAL) under the starter.
(b) Fill the starter with 16 fl. oz. (473.2 ml) to 20 fl. oz. (591.4 ml) of
(4) Install the fill plug (2) to the starter as follows:
(a) Apply
(b) Install the EIPC 80-11-01-01-130 PREFORMED PACKING (3) on the fill plug (2).
(c) Install the fill plug (2) to the starter as follows:
CAUTION:
DO NOT PUSH ON THE RETENTION TAB TO INSTALL THE FILL PLUG. IF YOU DO NOT OBEY THIS INSTRUCTION, DAMAGE TO THE FILL PLUG CAN OCCUR.
1 Hold the fill plug (2) at the square and press and turn the fill plug until it fully seats against the starter. 2 Make sure the fill plug (2) is fully seated against the mating surface.
3 Turn the fill plug (2) so the retention tab is under the bolt (1).
4 TORQUE the fill plug retention bolt (1) to between 100 and 90 lbf.in (1.13 and 1.02 m.daN )
. Subtask 80-11-00-410-062-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the right thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR.
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR.
Subtask 80-11-00-440-053-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the right thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
452AR.
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
462AR.
B. Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 80-11-00-410-063-A ** ON A/C NOT FOR ALL
Fill the Starter with Oil