W DOC AIRBUS | AMM A320F

Operational Check of EVMU through CFDS [IAE]


TASK 77-32-34-710-041-A
Operational Check of EVMU through CFDS


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-012-A
Procedure to Get Access to the SYSTEM REPORT/TEST/ENG Page
3. Job Set-up
Subtask 77-32-34-861-057-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuit (Ref. AMM TASK 24-41-00-861-002).
Subtask 77-32-34-865-059-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUENGINE/ENG1 AND 2/EVMU1EVR44
Subtask 77-32-34-869-071-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) On the 1(2) MCDU, get the SYSTEM REPORT/TEST ENG page (Ref. AMM TASK 31-32-00-860-012)
   (2) Push the line key adjacent to the EVMU indication: the first EVMU page comes into view.
F EVMU Menu ** ON A/C NOT FOR ALL
4. Procedure
Subtask 77-32-34-710-052-A ** ON A/C NOT FOR ALL
A. Test of the EVMU with the CFDS
ACTION
RESULT
1.Push the line key adjacent to the TEST indication to get the TEST program.
The TEST IN PROGRESS indication comes into view.
F EVMU Test ** ON A/C NOT FOR ALL
detail A.
After not many seconds: the SELF-TEST OK indication comes into view.
F EVMU Test ** ON A/C NOT FOR ALL
detail B.
2.On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
The CFDS menu comes into view.
3.Press the MCDU menu Key.
The MCDU menu comes into view.
NOTE: When a fault is found, the reference of the ATA chapter and the faulty element come into view.
F EVMU Test ** ON A/C NOT FOR ALL
detail C.
5. Close-up
Subtask 77-32-34-862-057-A ** ON A/C NOT FOR ALL
A. De-energize the aircraft electrical circuits (Ref. AMM TASK 24-41-00-862-002).