Visual Inspection of the Electronic Engine Control (EEC) Cooling Blowers (PRE SB72-01-91) [CFML]
TASK 75-24-05-210-801-A
Visual Inspection of the Electronic Engine Control (EEC) Cooling Blowers (PRE SB72-01-91)
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 75-24-05-941-054-A
Subtask 75-24-05-210-050-A
Subtask 75-24-05-410-052-A
[Rev.10 from 2021]
2026.04.01 03:14:45 UTC
Visual Inspection of the Electronic Engine Control (EEC) Cooling Blowers (PRE SB72-01-91)
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-803-A | Closing of the Fan Cowl Doors |
| TASK 75-24-05-000-801-A | Removal of the Electronic Engine Control (EEC) Cooling Blower (Lower) (PRE SB72-0191) |
| TASK 75-24-05-000-802-A | Removal of the Electronic Engine Control (EEC) Cooling Blower (Upper) (PRE SB72-0191) |
| TASK 75-24-05-000-803-A | Removal of the EEC Blower Fire Shield Blanket (PRE SB72-0191) |
| TASK 75-24-05-400-801-A | Installation of the Electronic Engine Control (EEC) Cooling Blower (Lower) (PRE SB72-0191) |
| TASK 75-24-05-400-802-A | Installation of the Electronic Engine Control (EEC) Cooling Blower (Upper) (PRE SB72-0191) |
| TASK 75-24-05-400-803-A | Installation of the EEC Blower Fire Shield Blanket (PRE SB72-0191) |
Subtask 75-24-05-941-054-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 75-24-05-010-054-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Put WARNING NOTICE(S) in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 1M(3 FT) in position.
(3) Remove the EEC blower fire shield blanket (Ref. AMM TASK 75-24-05-000-803).
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 1M(3 FT) in position.
(3) Remove the EEC blower fire shield blanket (Ref. AMM TASK 75-24-05-000-803).
Subtask 75-24-05-210-050-A
A. Visual Inspection of the Electronic Engine Control (EEC) Cooling Blower (Upper) (1) and EEC Cooling Blower (Lower) (2)
(1) Make sure that the labels (3) are correctly installed and information can be read.
(2) Do a visual inspection of all surfaces:
5. Close-up(1) Make sure that the labels (3) are correctly installed and information can be read.
(2) Do a visual inspection of all surfaces:
| INSPECT/CHECK | MAXIMUM SERVICEABLE LIMITS | REMARKS |
|---|---|---|
| Cracks | Not serviceable | Do the applicable steps as follows: (a) Replace the EEC cooling blower (upper) (1) (Ref. AMM TASK 75-24-05-000-802) and (Ref. AMM TASK 75-24-05-400-802). (b) Replace the EEC cooling blower (lower) (2) (Ref. AMM TASK 75-24-05-000-801) and (Ref. AMM TASK 75-24-05-400-801). |
| Dent | Not serviceable | Do the applicable steps as follows: (a) Replace the EEC cooling blower (upper) (1) (Ref. AMM TASK 75-24-05-000-802) and (Ref. AMM TASK 75-24-05-400-802). (b) Replace the EEC cooling blower (lower) (2) (Ref. AMM TASK 75-24-05-000-801) and (Ref. AMM TASK 75-24-05-400-801). |
| Tear | Not serviceable | Do the applicable steps as follows: (a) Replace the EEC cooling blower (upper) (1) (Ref. AMM TASK 75-24-05-000-802) and (Ref. AMM TASK 75-24-05-400-802). (b) Replace the EEC cooling blower (lower) (2) (Ref. AMM TASK 75-24-05-000-801) and (Ref. AMM TASK 75-24-05-400-801). |
| Corrosion | Not serviceable | Do the applicable steps as follows: (a) Replace the EEC cooling blower (upper) (1) (Ref. AMM TASK 75-24-05-000-802) and (Ref. AMM TASK 75-24-05-400-802). (b) Replace the EEC cooling blower (lower) (2) (Ref. AMM TASK 75-24-05-000-801) and (Ref. AMM TASK 75-24-05-400-801). |
| Erosion | Not serviceable | Do the applicable steps as follows: (a) Replace the EEC cooling blower (upper) (1) (Ref. AMM TASK 75-24-05-000-802) and (Ref. AMM TASK 75-24-05-400-802). (b) Replace the EEC cooling blower (lower) (2) (Ref. AMM TASK 75-24-05-000-801) and (Ref. AMM TASK 75-24-05-400-801). |
| Nicks | Not serviceable | Do the applicable steps as follows: (a) Replace the EEC cooling blower (upper) (1) (Ref. AMM TASK 75-24-05-000-802) and (Ref. AMM TASK 75-24-05-400-802). (b) Replace the EEC cooling blower (lower) (2) (Ref. AMM TASK 75-24-05-000-801) and (Ref. AMM TASK 75-24-05-400-801). |
| Scratch | Not serviceable | Do the applicable steps as follows: (a) Replace the EEC cooling blower (upper) (1) (Ref. AMM TASK 75-24-05-000-802) and (Ref. AMM TASK 75-24-05-400-802). (b) Replace the EEC cooling blower (lower) (2) (Ref. AMM TASK 75-24-05-000-801) and (Ref. AMM TASK 75-24-05-400-801). |
| Deposits | Not serviceable | Do the applicable steps as follows: (a) Replace the EEC cooling blower (upper) (1) (Ref. AMM TASK 75-24-05-000-802) and (Ref. AMM TASK 75-24-05-400-802). (b) Replace the EEC cooling blower (lower) (2) (Ref. AMM TASK 75-24-05-000-801) and (Ref. AMM TASK 75-24-05-400-801). |
Subtask 75-24-05-410-052-A
A. Close Access
(1) Install the EEC blower fire shield blanket (Ref. AMM TASK 75-24-05-400-803).
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(4) Remove the access platform(s).
(5) Remove the WARNING NOTICE(S).
(1) Install the EEC blower fire shield blanket (Ref. AMM TASK 75-24-05-400-803).
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(4) Remove the access platform(s).
(5) Remove the WARNING NOTICE(S).
Electronic Engine Control (EEC) Cooling Blowers