Installation of the Low-Pressure-Turbine Active-Clearance-Control (LPTACC) Wye Duct [CFML]
TASK 75-22-00-400-801-A
Installation of the Low-Pressure-Turbine Active-Clearance-Control (LPTACC) Wye Duct
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 75-22-00-941-054-A
Subtask 75-22-00-420-050-A
Subtask 75-22-00-410-056-A
[Rev.10 from 2021]
2026.04.01 03:14:19 UTC
Installation of the Low-Pressure-Turbine Active-Clearance-Control (LPTACC) Wye Duct
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE PARTS AFTER THE ENGINE SHUTDOWN. USE APPLICABLE THERMAL GLOVES. THE ENGINE PARTS CAN STAY HOT FOR ONE HOUR AFTER SHUTDOWN AND CAN BURN YOU.
ZONE: 400
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | AR | WARNING NOTICE(S) |
| No specific | Torque wrench: range to between 38 and 32 lbf.in (0.43 and 0.36 m.daN ) ![]() |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1) | |
| 437AL, 438AR, 451AL | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2) | |
| 447AL, 448AR, 461AL | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-13-00-010-803-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-803-A | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-809-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-809-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
| TASK 78-36-00-010-806-A | Opening of the Thrust Reverser Cowl Doors |
| TASK 78-36-00-410-806-A | Closing of the Thrust Reverser Cowl Doors |
Subtask 75-22-00-941-054-A
A. Safety Precautions
(1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Make sure that the WARNING NOTICE(S) are in position to tell persons not to operate:
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to energize FADEC 1(2).
Subtask 75-22-00-010-058-A (1) On the center pedestal, on ENG panel 115VU:
(a) Make sure that the ENG/MODE selector switch is in the NORM position.
(b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
(c) Make sure that the WARNING NOTICE(S) are in position to tell persons not to operate:
- The ENG/MODE selector switch
- The ENG/MASTER 1(2) control switch.
(a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
(b) Make sure that the WARNING NOTICE(S) is(are) in position to tell persons not to energize FADEC 1(2).
B. Get Access
(1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
Subtask 75-22-00-040-055-A (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-803):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
(2) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
C. Deactivation of the Thrust Reverser System for Maintenance
Subtask 75-22-00-010-059-A WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Make sure that you did the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-809). D. Get Access
(1) Make sure that the left thrust-reverser cowl-door is open (Ref. AMM TASK 78-36-00-010-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL
4. Procedure(1) Make sure that the left thrust-reverser cowl-door is open (Ref. AMM TASK 78-36-00-010-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL
Subtask 75-22-00-420-050-A
A. Installation of the LPTACC Aft Wye Duct
(1) Remove the COVER - PROTECTION and the CAP - PROTECTION from each opening, tube, hose and connector.
(2) Install the LPTACC aft wye duct (7) as follows:
(a) Put the LPTACC aft wye duct (7) in position between the LPTACC valve (1), the air duct (3) and the air duct (6).
(b) Loosely install the hose clamp (2) that attaches the LPTACC aft wye duct (7) to the LPTACC valve (1).
(c) Loosely install the hose clamp (4) that attaches the LPTACC aft wye duct (7) to the air duct (3).
(d) Loosely install the hose clamp (5) that attaches the LPTACC aft wye duct (7) to the air duct (6).
(e) TORQUE the hose clamp (2), the hose clamp (4) and the hose clamp (5) to between 38 and 32 lbf.in (0.43 and 0.36 m.daN )
.
(f) Inspection of the lengths of the hose clamp tabs
5. Close-up(1) Remove the COVER - PROTECTION and the CAP - PROTECTION from each opening, tube, hose and connector.
(2) Install the LPTACC aft wye duct (7) as follows:
(a) Put the LPTACC aft wye duct (7) in position between the LPTACC valve (1), the air duct (3) and the air duct (6).
(b) Loosely install the hose clamp (2) that attaches the LPTACC aft wye duct (7) to the LPTACC valve (1).
(c) Loosely install the hose clamp (4) that attaches the LPTACC aft wye duct (7) to the air duct (3).
(d) Loosely install the hose clamp (5) that attaches the LPTACC aft wye duct (7) to the air duct (6).
(e) TORQUE the hose clamp (2), the hose clamp (4) and the hose clamp (5) to between 38 and 32 lbf.in (0.43 and 0.36 m.daN )
. (f) Inspection of the lengths of the hose clamp tabs
WARNING:
USE EYE PROTECTION WHEN YOU CUT MATERIAL OR PARTS. THE PARTICLES CAN CAUSE DAMAGE TO YOUR EYES.
1 Make sure that the lengths of the hose clamp tabs are not more than 1.25 in. (31.75 mm) above the screw housing. If necessary, cut the tab(s) to the correct dimension. Burrs are not permitted. Subtask 75-22-00-410-056-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-410-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL
Subtask 75-22-00-440-054-A (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the left thrust-reverser cowl-door (Ref. AMM TASK 78-36-00-410-806):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL
B. Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-809).
Subtask 75-22-00-410-057-A
Low-Pressure-Turbine Active-Clearance-Control (LPTACC) Wye Duct