W DOC AIRBUS | AMM A320F

Engine Interface Unit (EIU) DISCRETE INPUTS Menu Data Status [PW11]


TASK 73-25-34-860-806-A
Engine Interface Unit (EIU) DISCRETE INPUTS Menu Data Status


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-32-00-860-012-A
Procedure to Get Access to the SYSTEM REPORT/TEST/ENG Page
3. Job Set-up
Subtask 73-25-34-861-065-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 73-25-34-865-092-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
FOR FIN: 4020KM1 (POWER PLANTDEMOUNTABLE, ENG 1)
49VUENGINE/1/FADEC A/AND EIU 12KS1A04
** ON A/C NOT FOR ALL
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R41
** ON A/C NOT FOR ALL
121VUENGINE/ENG1/FADEC B/AND EIU 14KS1R40
** ON A/C NOT FOR ALL
FOR FIN: 4020KM2 (POWER PLANTDEMOUNTABLE, ENG 2)
49VUENGINE/2/FADEC A/AND EIU 22KS2A05
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/FADEC B/AND EIU24KS2Q40
** ON A/C NOT FOR ALL
121VUENGINE/ENG2/FADEC B/AND EIU24KS2R41
Subtask 73-25-34-860-102-A ** ON A/C NOT FOR ALL
C. Aircraft Maintenance Configuration
   (1) On the left or right MCDU, get the SYSTEM REPORT/TEST ENG page (Ref. AMM TASK 31-32-00-860-012).
4. Procedure
Subtask 73-25-34-860-103-A ** ON A/C NOT FOR ALL
A. DISCRETE INPUTS (DSI)
NOTE: The current status of each DSI is updated every five seconds.
ACTION
RESULT
1.Push the line key adjacent to the EIU1(EIU2) indication on the MCDU.
The EIU1(EIU2) menu comes into view.
2.Push the line key adjacent to the TEST indication.
On the MENU page, the TEST menu comes into view.
3.Push the line key adjacent to the SPECIFIC DATA indication.
On the MENU page, the SPECIFIC DATA menu comes into view.
4.Push the line key adjacent to the DISCRETE INPUTS indication.
The DISCRETE INPUTS menu comes into view.
NOTE: When the DSI is connected to an electrical ground circuit, then the status displayed shall be 1 (= True state).

When the DSI is connected to an electrical open circuit, then the status displayed shall be 0 (= False state).

When the DSI is failed, then the status displayed shall be a dash (-).
5.On the MCDU control panel, push the NEXT PAGE key.
The other pages come into view.
6.On the MCDU, push the line key adjacent to the RETURN indication until the CFDS menu page comes into view.

7.Stop the MCDU.

5. Close-up
Subtask 73-25-34-862-063-A ** ON A/C NOT FOR ALL
A. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 13:06:48 UTC