Correct Faults of the Engine Scheduled Maintenance Report (SMR) [CFMI]
TASK 73-21-60-740-028-A
Correct Faults of the Engine Scheduled Maintenance Report (SMR)
1. Reason for the Job
Refer to the MPD TASK: 730000-C2
CORRECT FAULTS OF THE ENGINE SCHEDULED MAINTENANCE REPORT (SMR).
This task is applicable only for CFM56-5A FADEC STD 5.A.I. and subsequent.
You can get access to single channel ALPHA and BETA faults detected during normal mode operation and stored in NVM through the SCHEDULED MAINTENANCE report from the ENGINE 1(2) MAIN MENU. Data for the last 12 faults isolated during the last 64 flight legs is shown on the MCDU in reverse chronological order (the last ones first).
A. Referenced Information
3. Job Set-up
Subtask 73-21-60-861-075-A ** ON A/C NOT FOR ALL Subtask 73-21-60-869-077-A ** ON A/C NOT FOR ALL
Subtask 73-21-60-740-075-A ** ON A/C NOT FOR ALL
Subtask 73-21-60-860-080-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:56:55 UTC
Correct Faults of the Engine Scheduled Maintenance Report (SMR)
1. Reason for the Job
Refer to the MPD TASK: 730000-C2
CORRECT FAULTS OF THE ENGINE SCHEDULED MAINTENANCE REPORT (SMR).
This task is applicable only for CFM56-5A FADEC STD 5.A.I. and subsequent.
You can get access to single channel ALPHA and BETA faults detected during normal mode operation and stored in NVM through the SCHEDULED MAINTENANCE report from the ENGINE 1(2) MAIN MENU. Data for the last 12 faults isolated during the last 64 flight legs is shown on the MCDU in reverse chronological order (the last ones first).
NOTE: Single channel ALPHA and BETA faults detected during menu mode tests are shown on the TEST REPORT screen of the test you did.
2. Job Set-up InformationA. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-32-00-860-012-A | Procedure to Get Access to the SYSTEM REPORT/TEST/ENG Page |
Subtask 73-21-60-861-075-A ** ON A/C NOT FOR ALL Subtask 73-21-60-869-077-A ** ON A/C NOT FOR ALL
B. Preparation for test
(1) On the overhead maintenance panel 50VU, push then release the ENG/FADEC GND PWR/1(2) pushbutton switch. The ON legend comes on.
(2) On the left or right MCDU get the SYSTEM REPORT/TEST ENG page (Ref. AMM TASK 31-32-00-860-012).
4. Procedure(1) On the overhead maintenance panel 50VU, push then release the ENG/FADEC GND PWR/1(2) pushbutton switch. The ON legend comes on.
(2) On the left or right MCDU get the SYSTEM REPORT/TEST ENG page (Ref. AMM TASK 31-32-00-860-012).
Subtask 73-21-60-740-075-A ** ON A/C NOT FOR ALL
A. Do this procedure for the ECU 1(2) channel A.
(1) Do this procedure for the ECU 1(2) channel B.
(2) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
(3) Stop the MCDU.
5. Close-upNOTE: This test is for the system 1. For the other system(s), use the indications between the parentheses.
| ACTION | RESULT |
|---|---|
| 1.On the MCDU: | |
|
|
| 2.Push the line key adjacent to the SCHEDULED MAINT REPORT indication. |
|
| | |
(2) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
(3) Stop the MCDU.
Subtask 73-21-60-860-080-A ** ON A/C NOT FOR ALL
A. On the overhead maintenance panel 50VU:
Subtask 73-21-60-862-073-A ** ON A/C NOT FOR ALL - Push the ENG/FADEC GND PWR 1(2) pushbutton switch. The ON legend goes off.
Scheduled Maintenance Report