Read the Specific Data Report [CFMB]
TASK 73-21-60-740-027-A
Read the Specific Data Report
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 73-21-60-861-065-A ** ON A/C NOT FOR ALL Subtask 73-21-60-869-067-A ** ON A/C NOT FOR ALL
Subtask 73-21-60-740-060-A ** ON A/C NOT FOR ALL
Subtask 73-21-60-860-068-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:59:23 UTC
Read the Specific Data Report
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 31-32-00-860-012-A | Procedure to Get Access to the SYSTEM REPORT/TEST/ENG Page |
Subtask 73-21-60-861-065-A ** ON A/C NOT FOR ALL Subtask 73-21-60-869-067-A ** ON A/C NOT FOR ALL
B. Preparation for test
(1) On the overhead maintenance panel 50VU, push then release the ENG/FADEC GND PWR/1(2) pushbutton switch. The ON legend comes on.
(2) On the left or right MCDU get the SYSTEM REPORT/TEST ENG page (Ref. AMM TASK 31-32-00-860-012).
4. Procedure(1) On the overhead maintenance panel 50VU, push then release the ENG/FADEC GND PWR/1(2) pushbutton switch. The ON legend comes on.
(2) On the left or right MCDU get the SYSTEM REPORT/TEST ENG page (Ref. AMM TASK 31-32-00-860-012).
Subtask 73-21-60-740-060-A ** ON A/C NOT FOR ALL
A. Do this procedure for the ECU 1(2) channel A.
(1) Do this procedure for the ECU 1(2) channel B.
(2) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
(3) Stop the MCDU.
5. Close-upNOTE: This test is for the system 1. For the other system(s), use the indications between the parentheses.
| ACTION | RESULT |
|---|---|
| 1.On the MCDU: | |
|
|
| 2.Push the line key adjacent to the SPECIFIC DATA indication. |
|
| 3.Push the line key adjacent to the PWR SETTING MAX VALUES indication. |
NOTE: If the value of one of these parameters is higher than the max limit, the report also shows how long (in seconds) the associated parameter was at that limit. If no overlimit condition occured, there is no time indication. NOTE: You can reset these values if necessary. To do this, push the line key adjacent to the RESET MAX VALUES then CONFIRM RESET indications. |
(2) On the MCDU, push the line select key adjacent to the RETURN indication until the CFDS menu page comes into view.
(3) Stop the MCDU.
Subtask 73-21-60-860-068-A ** ON A/C NOT FOR ALL
A. On the overhead maintenance panel 50VU:
Subtask 73-21-60-862-064-A ** ON A/C NOT FOR ALL - Push the ENG/FADEC GND PWR 1(2) pushbutton switch. The ON legend goes off.