Removal of the Main Fuel Supply Hose [CFMB]
TASK 73-11-11-000-041-A
Removal of the Main Fuel Supply Hose
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 73-11-11-941-050-A ** ON A/C NOT FOR ALL
Subtask 73-11-11-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 02:57:38 UTC
Removal of the Main Fuel Supply Hose
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M(3 FT) |
| No specific | 1 | CONTAINER 20 L - SHALLOW |
| No specific | AR | COVER - PROTECTION |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [1000EM1] (ENGINE-1) | |
| 437AL, 438AR | |
| FOR [1000EM2] (ENGINE-2) | |
| 447AL, 448AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 71-13-00-010-040-B | Opening of the Fan Cowl Doors |
Subtask 73-11-11-941-050-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
Subtask 73-11-11-861-053-A ** ON A/C NOT FOR ALL Subtask 73-11-11-865-055-A ** ON A/C NOT FOR ALL (1) On the center pedestal, on the ENG panel 115VU:
(a) Put a WARNING NOTICE(S) to tell persons not to start the engine.
(2) Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.
(3) On the overhead maintenance panel 50VU:
(a) Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.
(b) Put a WARNING NOTICE(S) to tell persons not to energize the FADEC 1(2).
C. Open, safety and tag this(these) circuit breaker(s):
Subtask 73-11-11-862-053-A ** ON A/C NOT FOR ALL Subtask 73-11-11-010-050-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| FOR FIN: 1000EM1 (ENGINE1) | |||
| 49VU | FUEL/LP VALVE/MOT1/ENG1 | 1QG | A08 |
| 121VU | FUEL/LP VALVE/MOT2/ENG1 | 3QG | M25 |
| FOR FIN: 1000EM2 (ENGINE2) | |||
| 49VU | FUEL/LP VALVE/MOT1/ENG2 | 2QG | A09 |
| 121VU | FUEL/LP VALVE/MOT2/ENG2 | 4QG | M26 |
E. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
4. Procedure(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-040):
(a) FOR [1000EM1] (ENGINE-1)
437AL 438AR
(b) FOR [1000EM2] (ENGINE-2)
447AL 448AR
(2) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 73-11-11-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Main Fuel Supply Hose
(1) Remove the bolts (5), the washers (15), the nuts (20) and the clamp (10) from the upper bracket.
(2) Remove the bolts (5) and the clamp (10) from the middle bracket.
(3) Remove the bolts (5), the nuts (20) and the clamp (10) from the lower bracket.
(4) Put the CONTAINER 20 L - SHALLOW below the fuel manifold duct to catch the drained fuel.
(5) Cut and remove the lockwire from the bolts (30).
(6) Remove the bolts (30) and the washers (35) that attach the main fuel supply hose (25) to the fuel manifold duct. Let the fuel drain into the container.
(7) Remove the bolts (30) and the washers (35) that attach the hose (25) to the fluid disconnect panel.
(8) Remove and discard the gaskets (40).
(9) Put COVER - PROTECTION on the ends of the hose (25), the fluid disconnect panel and the fuel manifold duct.
(1) Remove the bolts (5), the washers (15), the nuts (20) and the clamp (10) from the upper bracket.
(2) Remove the bolts (5) and the clamp (10) from the middle bracket.
(3) Remove the bolts (5), the nuts (20) and the clamp (10) from the lower bracket.
(4) Put the CONTAINER 20 L - SHALLOW below the fuel manifold duct to catch the drained fuel.
(5) Cut and remove the lockwire from the bolts (30).
(6) Remove the bolts (30) and the washers (35) that attach the main fuel supply hose (25) to the fuel manifold duct. Let the fuel drain into the container.
(7) Remove the bolts (30) and the washers (35) that attach the hose (25) to the fluid disconnect panel.
(8) Remove and discard the gaskets (40).
(9) Put COVER - PROTECTION on the ends of the hose (25), the fluid disconnect panel and the fuel manifold duct.
Main Fuel Supply Hose