Detailed Inspection of the Engine Fan Case V-Groove [PW11]
TASK 72-21-01-220-804-A
Detailed Inspection of the Engine Fan Case V-Groove
Refer to the MPD TASK: 722102-01
DETAILED INSPECTION OF ENGINE FAN CASE V-GROOVE.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 72-21-01-941-055-A ** ON A/C NOT FOR ALL
Subtask 72-21-01-220-052-A ** ON A/C NOT FOR ALL
Subtask 72-21-01-410-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 13:02:26 UTC
Detailed Inspection of the Engine Fan Case V-Groove
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobRefer to the MPD TASK: 722102-01
DETAILED INSPECTION OF ENGINE FAN CASE V-GROOVE.
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR, 461AL, 462AR | |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-802-A | Closing of the Fan Cowl Doors |
| TASK 72-21-00-220-801-A | Detailed Visual Inspection (DVI) of the Fan Case External Surfaces |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-805-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
| TASK 78-36-00-010-802-A | Opening of the Thrust Reverser Cowl-Doors |
| TASK 78-36-00-410-802-A | Closing of the Thrust Reverser Cowl-Doors |
Subtask 72-21-01-941-055-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833)
Subtask 72-21-01-010-052-A ** ON A/C NOT FOR ALL (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833)
B. Get Access
(1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
Subtask 72-21-01-040-050-A ** ON A/C NOT FOR ALL (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL 448AR
(2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
C. Deactivation of the Thrust Reverser for Maintenance
Subtask 72-21-01-010-053-A ** ON A/C NOT FOR ALL WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-805). D. Get Access
(1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL 462AR
4. Procedure(1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL 462AR
Subtask 72-21-01-220-052-A ** ON A/C NOT FOR ALL
A. Detailed Visual Inspection (DVI) Of The Fan Case Outer V-Groove
(1) Examine the fan case outer V-groove. Inspect Area B only if the cowl door seal is removed. Refer to Table 1.
(2) Examine the fan cowl door seal (Ref. AMM TASK 72-21-00-220-801).
Table 1 Fan Case Outer V-Groove - Visual Inspection
(3) For all other damage (Ref. AMM TASK 72-21-00-220-801).
5. Close-up(1) Examine the fan case outer V-groove. Inspect Area B only if the cowl door seal is removed. Refer to Table 1.
(2) Examine the fan cowl door seal (Ref. AMM TASK 72-21-00-220-801).
Table 1 Fan Case Outer V-Groove - Visual Inspection
| EXAMINE | DAMAGE | DISPOSITION |
|---|---|---|
| Cracks in Area A and Area B | All quantities | Not permitted. Contact Pratt & Whitney. |
| Galling and chaffing in Area A | All quantities less than 0.005 in. (0.13 mm) in depth | Permitted for continued operation |
| | All quantities between 0.005 in. (0.13 mm) and 0.010 in. (0.25 mm) in depth | Contact Pratt & Whitney. |
| | All quantities more than 0.010 in. (0.25 mm) in depth | Not permitted |
| Nicks, scratches and dents in Area A | Any amount up to 0.005 in. (0.127 mm) depth | Permitted for continued service |
| | Any amount up to 0.020 in. (0.508 mm) depth | Contact Pratt & Whitney. |
| | Any amount more than 0.020 in. (0.508 mm) depth | Not permitted |
| Surface damage in Area B | Any amount | Contact Pratt & Whitney. |
Subtask 72-21-01-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL 462AR
Subtask 72-21-01-440-050-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL 462AR
B. Do the reactivation of the thrust reverser system after maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 72-21-01-410-052-A ** ON A/C NOT FOR ALL
Detailed Visual Inspection (DVI) Of The Fan Case Outer V-Groove