W DOC AIRBUS | AMM A320F

Inspection/Check of Exposed Hardware [CFML]


TASK 72-00-00-200-813-A
Inspection/Check of Exposed Hardware


1. Reason for the Job
Do a visual inspection of all hardware upon exposure
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL, 438AR, 451AL, 452AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL, 448AR, 461AL, 462AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 71-13-00-010-803-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-803-A
Closing of the Fan Cowl Doors
TASK 78-30-00-040-809-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-30-00-440-809-A
Reactivation of the Thrust Reverser System after Ground Maintenance
TASK 78-36-00-010-806-A
Opening of the Thrust Reverser Cowl Doors
TASK 78-36-00-410-806-A
Closing of the Thrust Reverser Cowl Doors
3. Job Set-up
Subtask 72-00-00-941-205-A
A. Safety Precautions
   (1) On the center pedestal, on ENG panel 115VU:
     (a) Make sure that the ENG/MODE selector switch is in the NORM position.
     (b) Make sure that the ENG/MASTER 1(2) control switch was in the OFF position not less than five minutes before you do this procedure.
     (c) Put WARNING NOTICE(S) in position to tell persons not to operate:
  • The ENG/MODE selector switch, and
  • The ENG/MASTER 1(2) control switch.
   (2) On the ENG section of maintenance panel 50VU:
     (a) Make sure that the ON legend of the FADEC GND PWR/1(2) pushbutton switch is off.
     (b) Put a WARNING NOTICE(S) in position to tell persons not to energize FADEC 1(2).
Subtask 72-00-00-010-273-A
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-803):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
   (2) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
Subtask 72-00-00-040-136-A
C. Deactivation of the Thrust Reverser System for Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Do the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-809).
Subtask 72-00-00-010-274-A
D. Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-806):
   (1) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
   (2) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
4. Procedure
Subtask 72-00-00-210-168-A
CAUTION: IF YOU MOVE THE FAN WHEEL, TURN THE FAN ROTOR COUNTERCLOCKWISE FORWARD LOOKING AFT. IF YOU TURN IT CLOCKWISE FORWARD LOOKING AFT, THERE IS A RISK THAT THE FAN BLADES WILL TOUCH THE ABRADABLE STRIP. THIS CAN CAUSE DAMAGE TO THE FAN BLADES AND THE ABRADABLE STRIP.
A. Visual Inspection of Exposed Hardware
NOTE: Exposed hardware inspection can be done with the parts installed or removed.
   (1) Exposed hardware inspection requirements
     (a) An individually licensed technician or a licensed repair station (if there is no individually licensed technician), must do a visual inspection of all the engine parts that can be seen, before the engine is assembled again. This includes the items that follow:
       1 All the parts that are removed from the engine and that will be installed again
       2 All the parts that are not removed from the engine and that can now be seen.
     (b) There must be a full inspection of these parts, and the parts must meet the serviceability limits given in the inspection limits that are applicable for the level of maintenance.
     (c) It is not necessary to disassemble a part more if the area that can be seen is in the serviceable limits.
5. Close-up
Subtask 72-00-00-410-233-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust-reverser cowl-doors (Ref. AMM TASK 78-36-00-410-806)
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
451AL 452AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
461AL 462AR
Subtask 72-00-00-440-129-A
B. Do the reactivation of the Thrust Reverser after maintenance (Ref. AMM TASK 78-30-00-440-809).
Subtask 72-00-00-410-234-A
C. Close Access
   (1) Close the fan cowl doors: (Ref. AMM TASK 71-13-00-410-803)
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENGINE 1)
437AL 438AR
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENGINE 2)
447AL 448AR
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 02:50:42 UTC