W DOC AIRBUS | AMM A320F

Detailed Visual Inspection of the Aft Engine Mount Assembly [PW11]


TASK 71-22-41-210-802-A
Detailed Visual Inspection of the Aft Engine Mount Assembly


WARNING: BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING: ALWAYS USE APPLICABLE GLOVES TO TOUCH HOT PARTS. HOT PARTS CAN CAUSE INJURY TO PERSONS.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 400
1. Reason for the Job
NOTE: In this task the Aft engine mounts are removed from the pylon and installed on the engine.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
FLASHLIGHT - HIGHPOWER
No specific
AR
MIRROR - INSPECTION
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.P05-005)
wipe, lint-free
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
400
POWER PLANT, NACELLES AND PYLONS
FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR, 451AL, 452AR
FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR, 461AL, 462AR
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 71-00-00-860-833-A
Procedure to Prevent Engine Motoring
TASK 71-13-00-010-802-A
Opening of the Fan Cowl Doors
TASK 71-13-00-410-802-A
Closing of the Fan Cowl Doors
TASK 78-30-00-040-805-A
Deactivation of the Thrust Reverser System for Ground Maintenance
TASK 78-30-00-440-805-A
Reactivation of the Thrust Reverser System after Ground Maintenance
TASK 78-36-00-010-802-A
Opening of the Thrust Reverser Cowl-Doors
TASK 78-36-00-410-802-A
Closing of the Thrust Reverser Cowl-Doors
3. Job Set-up
Subtask 71-22-41-941-061-A ** ON A/C NOT FOR ALL
A. Safety Precautions
   (1) Do the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 71-22-41-010-087-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the fan cowl doors (Ref. AMM TASK 71-13-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR.
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR.
   (2) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position.
Subtask 71-22-41-040-061-A ** ON A/C NOT FOR ALL
C. Deactivation of the Thrust Reverser for Ground Maintenance
WARNING: YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
   (1) Do the deactivation of the thrust reverser system for ground maintenance (Ref. AMM TASK 78-30-00-040-805).
Subtask 71-22-41-010-093-A ** ON A/C NOT FOR ALL
D. Get Access
   (1) Open the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-010-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL, 452AR.
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL, 462AR.
4. Procedure
Subtask 71-22-41-220-051-A ** ON A/C NOT FOR ALL
A. Detailed Visual Inspection of the Aft Engine Mount Assembly
NOTE: You can use the MIRROR - INSPECTION and the FLASHLIGHT - HIGHPOWER.
   (1) Get access to the nozzle 12 o'clock area (engine junction area).
   (2) Clean any dirt or unwanted material from the aft engine mount with P05-005wipe, lint-free.
   (3) Do the visual inspection of the aft-beam assembly (1) for:
  • Cracks
  • Damage
  • Scratches
  • Corrosion.
   (4) Do the visual inspection of the aft-mount shackle (4) for:
  • Cracks
  • Damage
  • Scratches
  • Corrosion.
   (5) Do the visual inspection of the aft-mount link (2) for:
  • Cracks
  • Damage
  • Scratches
  • Corrosion.
   (6) Do the visual inspection of the aft-mount bolt (8) for:
  • Good installation (No play permitted).
  • Presence and good condition of the locking plates (7), the screws (6) and the retainers (5).
   (7) Do the visual inspection of the bolt (3) and the fail safe pin (9) of the secondary load path system for:
  • Cracks
  • Damage
  • Scratches
  • Corrosion.
5. Close-up
Subtask 71-22-41-410-069-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL, 452AR.
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL, 462AR.
Subtask 71-22-41-440-058-A ** ON A/C NOT FOR ALL
B. Do the reactivation of the thrust reverser system after ground maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 71-22-41-410-075-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
     (a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR.
     (b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR.
   (2) Remove the access platform(s).
   (3) Remove the WARNING NOTICE(S).
[Rev.10 from 2021] 2026.04.01 04:10:52 UTC