Installation of the Forward Mount Bolt (One at a time) [PW11]
TASK 71-21-41-400-807-A
Installation of the Forward Mount Bolt (One at a time)
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 71-21-41-941-067-A ** ON A/C NOT FOR ALL
Subtask 71-21-41-420-061-A ** ON A/C NOT FOR ALL
Subtask 71-21-41-410-081-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.01 12:57:32 UTC
Installation of the Forward Mount Bolt (One at a time)
WARNING:
BE CAREFUL WHEN YOU DO WORK ON THE ENGINE AFTER SHUTDOWN. THE ENGINE CAN STAY HOT FOR A LONG TIME. IF YOU DO NOT OBEY THIS INSTRUCTION, INJURY CAN OCCUR.
WARNING:
ALWAYS USE APPLICABLE GLOVES TO TOUCH HOT PARTS. HOT PARTS CAN CAUSE INJURY TO PERSONS.
ZONE: 400
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| No specific | Torque wrench: range to between 0.47 and 0.37 m.daN (41.59 and 32.74 lbf.in ) ![]() | |
| No specific | Torque wrench: range to between 57.2 and 46.8 m.daN (421.83 and 345.13 lbf.ft ) ![]() | |
| 98D71203013000 | 1 | TORQUE WRENCH SET PW |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.360200) | MOLYKOTE G-RAPID PLUS PASTE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 400 | POWER PLANT, NACELLES AND PYLONS |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR, 461AL, 462AR | |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 7 | SCREW | EIPC 71-21-86-03-010 |
| 5 | SCREW | EIPC 71-21-86-03-020 |
| 9 | BOLT | EIPC 71-21-86-03-030 |
| 10 | WASHER | EIPC 71-21-86-03-040 |
| 3 | WASHER | EIPC 71-21-86-03-040 |
| 2 | NUT | EIPC 71-21-86-03-050 |
| 8 | LOCKING PLATE | EIPC 71-21-86-03-060 |
| 11 | RETAINER | EIPC 71-21-86-03-070 |
| 4 | RETAINER BRACKETS | EIPC 71-21-86-03-090 |
| 1 | RETAINER | EIPC 71-21-86-03-100 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-010-802-A | Opening of the Fan Cowl Doors |
| TASK 71-13-00-410-802-A | Closing of the Fan Cowl Doors |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-805-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
| TASK 78-36-00-010-802-A | Opening of the Thrust Reverser Cowl-Doors |
| TASK 78-36-00-410-802-A | Closing of the Thrust Reverser Cowl-Doors |
Subtask 71-21-41-941-067-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
Subtask 71-21-41-010-093-A ** ON A/C NOT FOR ALL (1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
B. Get Access
(1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR.
(2) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
Subtask 71-21-41-040-067-A ** ON A/C NOT FOR ALL (1) Make sure that the fan cowl doors are open (Ref. AMM TASK 71-13-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
437AL, 438AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
447AL, 448AR.
(2) Make sure that the ACCESS PLATFORM 1M(3 FT) is in position.
C. Deactivation of the Thrust Reverser System for Maintenance
Subtask 71-21-41-010-094-A ** ON A/C NOT FOR ALL WARNING:
YOU MUST DEACTIVATE THE THRUST REVERSER BEFORE YOU DO WORK ON OR AROUND IT. IF YOU DO NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE AN INJURY AND/OR DAMAGE.
(1) Make sure that you did the deactivation of the thrust reverser system for maintenance (Ref. AMM TASK 78-30-00-040-805). D. Get Access
(1) Make sure that the thrust reverser cowl-doors are open (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL, 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL, 462AR.
4. Procedure(1) Make sure that the thrust reverser cowl-doors are open (Ref. AMM TASK 78-36-00-010-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL, 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL, 462AR.
Subtask 71-21-41-420-061-A ** ON A/C NOT FOR ALL
A. Installation of the Forward Engine Mount Bolts (One at a time)
(2) Apply MOLYKOTE G-RAPID PLUS PASTE (Material No.360200) :
.
(4) Install the EIPC 71-21-86-03-100 RETAINER (1) and attach it to the EIPC 71-21-86-03-090 RETAINER BRACKETS (4) with the EIPC 71-21-86-03-020 SCREW (5).
(5) TORQUE the screw (5) to between 0.47 and 0.37 m.daN (41.59 and 32.74 lbf.in )
.
(6) Install the Locking Plate system of the forward Engine Mount.
(a) Install the EIPC 71-21-86-03-060 LOCKING PLATE (8) and attach it to the EIPC 71-21-86-03-070 RETAINER (11) with the EIPC 71-21-86-03-010 SCREW (7).
(b) TORQUE the screws (7) to between 0.47 and 0.37 m.daN (41.59 and 32.74 lbf.in )
.
5. Close-upNOTE: This procedure is applicable to one forward engine mount bolt.
(1) Install the new EIPC 71-21-86-03-030 BOLT (9), new EIPC 71-21-86-03-040 WASHER (10), new EIPC 71-21-86-03-050 NUT (2) and new EIPC 71-21-86-03-040 WASHER (3). (2) Apply MOLYKOTE G-RAPID PLUS PASTE (Material No.360200) :
- Below the screws heads
- On the screws and nuts threads
- On the two faces of the washers.
CAUTION:
MAKE SURE THAT THE PROTRUSION OF THE BOLT ABOVE THE NUT IS EQUAL TO OR MORE THAN THE DIMENSION OF THE BOLT THREAD CHAMFER. IF THE PROTRUSION IS NOT SUFFICIENT, THERE IS A RISK THAT THE BOLT WILL NOT BE CORRECTLY INSTALLED.
(a) TORQUE the forward mount bolts (9) with 98D71203013000 TORQUE WRENCH SET PW to between 57.2 and 46.8 m.daN (421.83 and 345.13 lbf.ft )
.(4) Install the EIPC 71-21-86-03-100 RETAINER (1) and attach it to the EIPC 71-21-86-03-090 RETAINER BRACKETS (4) with the EIPC 71-21-86-03-020 SCREW (5).
(5) TORQUE the screw (5) to between 0.47 and 0.37 m.daN (41.59 and 32.74 lbf.in )
. (6) Install the Locking Plate system of the forward Engine Mount.
(a) Install the EIPC 71-21-86-03-060 LOCKING PLATE (8) and attach it to the EIPC 71-21-86-03-070 RETAINER (11) with the EIPC 71-21-86-03-010 SCREW (7).
(b) TORQUE the screws (7) to between 0.47 and 0.37 m.daN (41.59 and 32.74 lbf.in )
. Subtask 71-21-41-410-081-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL, 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL, 462AR.
Subtask 71-21-41-440-061-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
451AL, 452AR
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
461AL, 462AR.
B. Do the reactivation of the thrust reverser system after maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 71-21-41-410-082-A ** ON A/C NOT FOR ALL
Forward Mount Bolt