Installation of the Nose Fire Seal
TASK 54-57-22-400-811-A
Installation of the Nose Fire Seal
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Expendable Parts
E. Referenced Information
3. Job Set-up
Subtask 54-57-22-941-096-A ** ON A/C NOT FOR ALL
Subtask 54-57-22-420-071-A ** ON A/C NOT FOR ALL
Subtask 54-57-22-410-066-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2017]
2026.04.01 02:04:19 UTC
Installation of the Nose Fire Seal
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.08BAA9) | Non Aqueous Cleaner-General - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 410 | ENG 1 PYLON BOX AND FORWARD FAIRING |
| 420 | ENG 2 PYLON BOX AND FORWARD FAIRING |
| FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1) | |
| 437AL, 438AR, 451AL, 452AR | |
| FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2) | |
| 447AL, 448AR, 461AL, 462AR | |
| FIG.ITEM | DESIGNATION | IPC-CSN |
|---|---|---|
| 4 | seal | AIPC 54-57-82-23-140 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 71-00-00-860-833-A | Procedure to Prevent Engine Motoring |
| TASK 71-13-00-410-802-A | Closing of the Fan Cowl Doors |
| TASK 72-21-04-400-801-A | Installation of the Fan Exit Fairing - Upper Bifi |
| TASK 78-30-00-040-805-A | Deactivation of the Thrust Reverser System for Ground Maintenance |
| TASK 78-30-00-440-805-A | Reactivation of the Thrust Reverser System after Ground Maintenance |
| TASK 78-36-00-410-802-A | Closing of the Thrust Reverser Cowl-Doors |
Subtask 54-57-22-941-096-A ** ON A/C NOT FOR ALL
A. Safety Precautions
(1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
(2) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position:
(a) For the left pylon, at zone 410
(b) For the right pylon, at zone 420.
Subtask 54-57-22-040-067-A ** ON A/C NOT FOR ALL (1) Make sure that you did the procedure to prevent engine motoring
(Ref. AMM TASK 71-00-00-860-833).
(2) Make sure that the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE is in position:
(a) For the left pylon, at zone 410
(b) For the right pylon, at zone 420.
B. Deactivation of the Thrust Reverser
Subtask 54-57-22-110-062-A ** ON A/C NOT FOR ALL WARNING:
MAKE SURE THAT THE THRUST REVERSER IS LOCKED. IF NOT, THE THRUST REVERSER CAN OPERATE ACCIDENTALLY AND CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE REVERSER.
(1) Make sure that the thrust reverser is unserviceable for maintenance (Ref. AMM TASK 78-30-00-040-805). C. Preparation for Installation
(1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Clean the parts kept from the removed component with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) , if necessary.
(3) Do an inspection of the component interfaces and the adjacent area.
(4) Install the fan exit fairing - upper Bifi (Ref. AMM TASK 72-21-04-400-801).
4. Procedure(1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Clean the parts kept from the removed component with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) , if necessary.
(3) Do an inspection of the component interfaces and the adjacent area.
(4) Install the fan exit fairing - upper Bifi (Ref. AMM TASK 72-21-04-400-801).
Subtask 54-57-22-420-071-A ** ON A/C NOT FOR ALL
A. Installation of the Nose Fire Seal
(1) Make sure that the nose fire seal (4) is in the correct condition. If it is not in the correct condition, discard it and install a new nose fire seal (4).
(2) Put and hold the nose fire seal (4) in position.
(3) Install the washers (1) and the nuts (2).
(4) Install the nut (3).
(5) TORQUE the nuts (2) and (3) to between 0.17 and 0.13 m.daN (15.04 and 11.50 lbf.in )
.
Subtask 54-57-22-420-071-B ** ON A/C NOT FOR ALL (1) Make sure that the nose fire seal (4) is in the correct condition. If it is not in the correct condition, discard it and install a new nose fire seal (4).
(2) Put and hold the nose fire seal (4) in position.
(3) Install the washers (1) and the nuts (2).
(4) Install the nut (3).
(5) TORQUE the nuts (2) and (3) to between 0.17 and 0.13 m.daN (15.04 and 11.50 lbf.in )
. A. Installation of the Nose Fire Seal
(1) Make sure that nose fire seal (4) is in the correct condition. If it is not in the correct condition, discard it and install a new nose fire AIPC 54-57-82-23-140 seal (4).
(2) Put and hold the nose fire seal (4) in position.
(3) Install the washers (1) and the nuts (2).
(4) Install the nut (3).
(5) TORQUE the nuts (2) and (3) to between 4.7 and 3.7 m.N (41.59 and 32.74 lbf.in )
.
5. Close-up(1) Make sure that nose fire seal (4) is in the correct condition. If it is not in the correct condition, discard it and install a new nose fire AIPC 54-57-82-23-140 seal (4).
(2) Put and hold the nose fire seal (4) in position.
(3) Install the washers (1) and the nuts (2).
(4) Install the nut (3).
(5) TORQUE the nuts (2) and (3) to between 4.7 and 3.7 m.N (41.59 and 32.74 lbf.in )
. Subtask 54-57-22-410-066-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
Subtask 54-57-22-440-060-A ** ON A/C NOT FOR ALL (1) Close the thrust reverser cowl-doors (Ref. AMM TASK 78-36-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
(2) Close the fan cowl doors (Ref. AMM TASK 71-13-00-410-802):
(a) FOR [4020KM1] (POWER PLANT-DEMOUNTABLE, ENG 1)
(b) FOR [4020KM2] (POWER PLANT-DEMOUNTABLE, ENG 2)
B. Reactivation of the Thrust Reverser
(1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-805).
Subtask 54-57-22-942-059-A ** ON A/C NOT FOR ALL (1) Make the thrust reverser serviceable after maintenance (Ref. AMM TASK 78-30-00-440-805).
C. Aircraft Maintenance Configuration
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Remove the access platform(s).
(3) Remove the WARNING NOTICE(S).
Nose Fire Seal